Table 14. B200xxxx Logical partition SRCs (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v
See Chapter 3, “Parts listing, Type 8406,” on page 229 to determine which components are CRUs and which
components are FRUs.
B200 xxxx
Reference Code
Description
Action
B200F001
A problem occurred during the
startup of a partition. An operation
has timed out.
Look for other errors and resolve them.
B200F003
During the startup of a partition, the
partition processor(s) did not start
the firmware within the time-out
window.
Collect the partition dump information; then, go to
“Isolating firmware problems” on page 218.
B200F004
Informational system log entry only.
No corrective action is required.
B200F005
Informational system log entry only.
No corrective action is required.
B200F006
During the startup of a partition, the
code load operation for the partition
startup timed out.
1.
Check the error logs and take the actions for the error
codes that are found.
2.
Go to “Isolating firmware problems” on page 218.
B200F007
During a shutdown of the partition,
a time-out occurred while trying to
stop a partition.
Check for server firmware updates; then, install the
updates if available.
B200F008
Informational system log entry only.
No corrective action is required.
B200F009
Informational system log entry only.
No corrective action is required.
B200F00A
Informational system log entry only.
No corrective action is required.
B200F00B
Informational system log entry only.
No corrective action is required.
B200F00C
Informational system log entry only.
No corrective action is required.
B200F00D
Informational system log entry only.
No corrective action is required.
B700xxxx Licensed internal code SRCs
A B700xxxx system reference code (SRC) is an error code or event code that is related to licensed internal
code.
Table 15 describes the system reference codes that might be displayed if system firmware detects a
problem. Suggested actions to correct the problem are also listed.
Note:
For problems persisting after completing the suggested actions, see “Checkout procedure” on page
184 and “Solving undetermined problems” on page 227.
Table 15. B700xxxx Licensed internal code SRCs
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v
See Chapter 3, “Parts listing, Type 8406,” on page 229 to determine which components are CRUs and which
components are FRUs.
B700 xxxx Error Codes
Description
Action
0102
System firmware detected an error. A
machine check occurred during startup.
1.
Collect the event log information.
2.
Go to “Isolating firmware problems” on
page 218.