Core electronics:
v
64-bit Power 7 processors (12S
technology)
v
Four core, single socket (4-way)
processors @ 3.0 GHz
v
64 GB maximum in 8 very low
profile (VLP) DIMM slots; Supports
4 GB DDR3 at 1066MHz, and 8 GB
DDR3 at 800HMz
P5IOC2 I/O hub
On-board, integrated features:
v
Two 1 GB Ethernet ports (HEA)
(two on each side)
v
SAS controller
v
USB 2.0
v
1 Serial over LAN (SOL) console
using FSP
FSP1 Service Processor - IPMI and
SOL
v
The baseboard management
controller (BMC) is a flexible
service processor (FSP1) with
Intelligent Platform Management
Interface (IPMI), Serial over LAN
(SOL), and Wake on LAN (WOL)
firmware support.
Local Storage:
v
First DASD bay: zero or one 2.5"
SAS HDD
v
Second DASD bay: zero or one 2.5"
SAS HDD
v
SAS HDDs are 300 GB and 600 GB
v
Hardware mirroring
Daughter card I/O options:
v
1 1Xe expansion card (CIOv)
v
SAS Pass-through using 1Xe
v
1 High-Speed expansion card
(CFFh)
Integrated functions:
v
RS-485 interface for
communication with the
management module
v
Automatic server restart (ASR)
v
SOL through FSP
v
Two Universal Serial Bus (USB
2.0) buses on base planar for
communication with
removable-media drives
v
Optical media available by shared
chassis feature
Environment:
v
Air temperature:
– Blade server on: 10° to 35°C
(50° to 95°F). Altitude: 0 to 914
m (3000 ft)
– Blade server on: 10° to 32°C
(50° to 90°F). Altitude: 914 m to
2133 m (3000 ft to 7000 ft)
– Blade server off: -40° to 60°C
(-40° to 140°F)
v
Humidity:
– Blade server on: 8% to 80%
– Blade server off: 8% to 80%
PS700 Size:
v
Height: 24.5 cm (9.7 inches)
v
Depth: 44.6 cm (17.6 inches)
v
Width: 30 mm (1.14 inches)
Systems management:
v
Supported by BladeCenter chassis
management module
v
Front panel LEDs
v
IBM Director
v
Hardware Management Console
(HMC)
v
Integrated Virtualization Manager
(IVM)
v
Energy Scale thermal management
for power management/
oversubscription (throttling) and
environmental sensing
v
Active Energy Manager
Clusters support for:
v
IBM Director
v
xCat
Virtualization support for:
PowerVM
®
Standard Edition hardware
feature, which provides the Integrated
Virtualization Manager, Virtual I/O
Server, and Director Power Systems
™
Manager (DPSM).
Reliability and service features:
v
Dual alternating current power
supply
v
BladeCenter chassis redundant and
hot plug power and cooling
modules
v
Boot-time processor deallocation
v
Blade server hot plug
v
Customer setup and expansion
v
Automatic reboot on power loss
v
Internal and ambient temperature
monitors
v
ECC, chipkill memory
v
System management alerts
Electrical input:
12 V dc
See the ServerProven Web site for information about supported operating-system versions and all PS700
blade server optional devices.
Chapter 1. Product overview
5
Summary of Contents for PS700
Page 1: ...Power Systems Installation and User s Guide for the IBM Power PS700 8406 70Y GI11 9830 00 ...
Page 2: ......
Page 3: ...Power Systems Installation and User s Guide for the IBM Power PS700 8406 70Y GI11 9830 00 ...
Page 6: ...iv Power Systems Installation and User s Guide for the IBM Power PS700 8406 70Y ...
Page 22: ...10 Power Systems Installation and User s Guide for the IBM Power PS700 8406 70Y ...
Page 30: ...18 Power Systems Installation and User s Guide for the IBM Power PS700 8406 70Y ...
Page 56: ...44 Power Systems Installation and User s Guide for the IBM Power PS700 8406 70Y ...
Page 60: ...48 Power Systems Installation and User s Guide for the IBM Power PS700 8406 70Y ...
Page 73: ......
Page 74: ... Part Number 16R2906 Printed in USA GI11 9830 00 1P P N 16R2906 ...