Form factor
The FC 5273 and FC EL2N are short, low-profile adapters; the FC 5735 and FC EL58 are short, full-
height adapters.
FC compatibility
2, 4, 8 Gigabit.
Cables
Cables are the responsibility of the customer.
Use multimode fiber optic cables with shortwave lasers that adhere to the following specifications:
• OM3: Multimode 50/125 micron fiber, 2000 MHz x km bandwidth
• OM2: Multimode 50/125 micron fiber, 500 MHz x km bandwidth
• OM1: Multimode 62.5/125 micron fiber, 200 MHz x km bandwidth
Because core sizes are different, OM1 cables can only be connected to other OM1 cables. For best
results, OM2 cables should not be connected to OM3 cables. However, if an OM2 cable is connected
to an OM3 cable, the characteristics of the OM2 cable apply to the entire length of the cables. The
following table shows the supported distances for the different fiber optic cable types at different link
speeds.
Table 13. Supported distances for multimode fiber optic cables
Header
Cable Type and Distance
Rate
OM1
OM2
OM3
2.125 Gbps
0.5 meters to 150
meters (1.64 feet to
492.12 feet)
0.5 meters to 300
meters (1.64 feet to
984.25 feet)
0.5 meters to 500
meters (1.64 feet to
1640.41 feet)
4.25 Gbps
0.5 meters to 70
meters (1.64 feet to
229.65 feet)
0.5 meters to 150
meters (1.64 feet to
492.12 feet)
0.5 meters to 380
meters (1.64 feet to
1246.71 feet)
8.5 Gbps
0.5 meters to 21
meters (1.64 feet to
68.89 feet)
0.5 meters to 50
meters (1.64 feet to
164.04 feet)
0.5 meters to 150
meters (1.64 feet to
492.12 feet)
Adapter LED
Green and yellow LEDs can be seen through openings in the mounting bracket of the adapter. Green
indicates firmware operation and yellow signifies port activity. Table 14 on page 62 summarizes the link
rate conditions. There is a 1-second pause when the LED is off between each group of fast flashes (2, 3,
or 4). Observe the LED sequence for several seconds to be sure that you have correctly identified the
state.
Table 14. Normal LED states
Green LED
Yellow LED
State
Slow flash
Off
Normal, link inactive or not
started
On
2 fast flashes
2 Gbps link rate - normal, link
active
On
3 fast flashes
4 Gbps link rate - normal, link
active
On
4 fast flashes
8 Gbps link rate - normal, link
active
62 Power Systems: Managing PCIe adapters
Summary of Contents for Power Systems Series
Page 4: ...iv...
Page 14: ...xiv Power Systems Managing PCIe adapters...
Page 79: ...Figure 8 PCIe 4 port Async EIA 232 1X adapter Managing PCIe adapters 65...
Page 105: ...Figure 21 PCIe3 LP 2 port 40 GbE NIC RoCE QSFP adapter FC EC3A Managing PCIe adapters 91...
Page 243: ......
Page 244: ...IBM...