v
No:
Go to step 22.
21.
Click OK to close the service action event.
22.
Is the list of all partitions you recorded in step 11 on page 45 empty?
v
Yes:
Go to step 30.
v
No:
Continue with the next step.
23.
Does the list of all partitions you recorded in step 11 on page 45 contain more than one entry?
v
Yes:
Continue with the next step.
v
No:
Go to step 30.
24.
Is the error class recorded in step 23?
v
Yes:
Continue with the next step.
v
No:
Go to step 30.
25.
Perform all the following steps for each entry in the list of all partitions you recorded in step 11 on
page 45, except for the partition you were using to debug the original problem.
26.
From the list of all partitions, open the IVM virtual terminal window of a partition, and then type
diag
at the AIX command prompt.
27.
When the diagnostic operating instructions are displayed, complete the following steps:
a.
Press Enter.
b.
Select the Task Selection option.
c.
Select the Log Repair option.
d.
Select the resource associated with the repair action:
v
If the repair action was reseating a cable or adapter, select the resource associated with that
repair action.
v
If the resource associated with your repair action is not displayed on the Resource List, select
sysplanar0
.
e.
Click Commit after you make your selection.
Note:
If the terminal type is not defined, you are prompted to define it before you can proceed.
28.
Exit from diagnostics in this partition and return to the AIX command prompt.
29.
Have all the partitions in the list of all partitions you recorded in step 11 on page 45 been processed?
v
Yes:
Continue with the next step.
v
No:
Go to step 25 to process the next partition in the list you recorded in step 11 on page 45.
30.
Have all the serviceable events recorded in step 4 on page 45 been processed?
v
Yes:
Continue with the next step.
v
No:
Go to step 5 on page 45 and process the next service action event in the list of serviceable
events recorded in step 4 on page 45.
31.
While processing all service action events, were you directed to step 14 on page 45?
v
Yes:
Continue with the next step.
v
No:
If the system attention LED is still on, turn off the LED as described in “Activating and
deactivating LEDs” on page 47. Return the system to the customer. This completes the repair.
Note:
If during the processing of the list of open service action events, some service action events
remained open, further service actions might be required to complete the repair.
32.
Complete all the following steps for each entry in the list of Axx partitions you began recording in
step 14 on page 45, except for the partition you were using to debug the original problem.
33.
From the list of Axx partitions, open the management console virtual terminal window of a partition
, and then type
diag
at the AIX command prompt.
34.
When the diagnostic operating instructions are displayed, complete the following steps:
46
Power Systems: Chassis management card for the EMX0 PCIe Gen3 I/O expansion drawer
Summary of Contents for Power Systems EMX0 PCIe Gen3
Page 1: ...Power Systems Chassis management card for the EMX0 PCIe Gen3 I O expansion drawer IBM ...
Page 2: ......
Page 3: ...Power Systems Chassis management card for the EMX0 PCIe Gen3 I O expansion drawer IBM ...
Page 16: ...xiv Power Systems Chassis management card for the EMX0 PCIe Gen3 I O expansion drawer ...
Page 24: ...8 Power Systems Chassis management card for the EMX0 PCIe Gen3 I O expansion drawer ...
Page 72: ...56 Power Systems Chassis management card for the EMX0 PCIe Gen3 I O expansion drawer ...
Page 84: ...68 Power Systems Chassis management card for the EMX0 PCIe Gen3 I O expansion drawer ...
Page 85: ......
Page 86: ...IBM ...