15.
Add the partition list obtained in step 11 on page 159 to the existing list of A
xx
partitions obtained
from processing previous service action events in this maintenance analysis procedure (MAP).
16.
Remove all entries in the list of all partitions you recorded in step 11 on page 159. If you are referred
to the list of partitions obtained in step 11 on page 159 in future steps, the list is empty. Go to step
17.
17.
Select and highlight the service action event from the Error Associated With This Serviceable Event
window.
18.
Click
Close Event
.
19.
Add comments for the serviceable event. Include any unique additional information. Click
OK
. The
following steps will add or update FRU information.
20.
Did you replace, add, or modify a FRU of the open service action event?
v
Yes:
Continue with the next step.
v
No:
Go to step 22.
21.
From the FRU list, select a FRU that you need to update. Double-click the FRU, and update the FRU
information. Go to step 23.
22.
Select the
No FRU Replaced for this Serviceable Event
option.
23.
Click
OK
to close the service action event.
24.
Is the list of all partitions you recorded in step 11 on page 159 empty?
v
Yes:
Go to step 32 on page 161.
v
No:
Continue with the next step.
25.
Does the list of all partitions you recorded in step 11 on page 159 contain more than one entry?
v
Yes:
Continue with the next step.
v
No:
Go to step 32 on page 161.
26.
Is the error class recorded in step 25 AIX?
160
Summary of Contents for Power System POWER7 Series
Page 1: ...Power Systems Common service procedures...
Page 2: ......
Page 3: ...Power Systems Common service procedures...
Page 8: ...vi...
Page 125: ...Figure 48 Lift up on the EMC shield Common service procedures 111...
Page 139: ...Figure 60 Lift up on the EMC shield Common service procedures 125...
Page 186: ...172...
Page 196: ...182...
Page 197: ......