68
POWER7 and Optimization and Tuning Guide
4.1 AIX and system libraries
Here we present information about AIX and system libraries.
4.1.1 AIX operating system-specific optimizations
This section describes optimization methods specific to AIX.
Malloc
Every application needs a fast, scalable, and memory efficient allocator. However, each
application’s memory request patterns are different. It is difficult to provide one common
allocator or tunable that can satisfy the needs of all applications. AIX provides different
memory allocators and suboptions within the allocator, so that a system administrator or
developer can choose more suitable settings for their application. This chapter explains the
available choices and when to choose them.
Memory allocators
AIX provides three different allocators, and each of them uses a different memory
management algorithm and data structures. These allocators work independently, so the
application developer must choose one of them by exporting the
MALLOCTYPE
environment variable. The allocators are:
Default allocator
The default allocator is selected when the
MALLOCTYPE
environment variable is unset. This
setting maintains a consistent performance, even in a worst case scenario, but might not
be as memory efficient as a Watson allocator. This allocator is ideal for 32-bit applications,
which do not make frequent calls to
malloc()
.
Watson allocator
This allocator is selected when
MALLOCTYPE=watson
is set. This allocator is designed for
64-bit applications. It is memory efficient, scalable, and provides good performance. This
allocator has a built-in bucket component for allocation requests up to 512 bytes. Table 4-1
provides the mapping for the allocation requests to bucket size.
Table 4-1 Mapping for allocation requests to bucket size
This allocator is ideal for 64-bit memory-intensive applications.
Request
size
Bucket
size
Request
size
Bucket
size
Request
size
Bucket
size
Request
size
Bucket
size
1 - 4
33-40
40
129-144
144
257-288
288
5 - 8
41 - 48
48
145 - 160
160
289 - 320
320
9 - 12
12
49 - 56
56
161 - 176
176
321 - 352
352
13 - 16
16
57 - 64
64
177 - 192
192
353 - 384
384
17 - 20
20
65 - 80
80
193 - 208
208
385 - 416
416
21 - 24
24
81 - 96
96
209 - 224
224
417 - 448
448
25 - 28
28
97 - 112
112
224 - 240
240
449 - 480
480
29 - 32
32
113 - 128
128
241 - 256
256
481 - 512
512
Summary of Contents for Power System POWER7 Series
Page 2: ......
Page 36: ...20 POWER7 and POWER7 Optimization and Tuning Guide...
Page 70: ...54 POWER7 and POWER7 Optimization and Tuning Guide...
Page 112: ...96 POWER7 and POWER7 Optimization and Tuning Guide...
Page 140: ...124 POWER7 and POWER7 Optimization and Tuning Guide...
Page 162: ...146 POWER7 and POWER7 Optimization and Tuning Guide...
Page 170: ...154 POWER7 and POWER7 Optimization and Tuning Guide...
Page 223: ......