CAUTION: Hazardous energy present. Voltages with hazardous energy might cause heating
when shorted with metal, which might result in splattered metal, burns, or both. (L005)
3. Remove the power supplies from the system as shown in the following figure.
a) To release a power supply from its position in the system, pull the locking-tab (A) to the left.
b) Grasp the power supply handle with one hand, and pull the power supply (B) partially out of the
system.
c) Place your other hand underneath the power supply and pull the power supply out of the system
and place it on an ESD mat.
d) Repeat steps “3.a” on page 69 - “3.c” on page 69 for the other power supply.
Figure 59. Removing the power supplies from the system
Replacing a power supply in the 9183-22X system
To replace a power supply in the system, complete the steps in this procedure.
Procedure
1. Ensure that you have the electrostatic discharge (ESD) wrist strap on and that the ESD clip is plugged
into a ground jack or connected to an unpainted metal surface. If not, do so now.
2. Replace the power supplies as shown in the following figure.
a) Place your other hand underneath the power supply.
b) Align the power supply (A) with the bay, so that the fan is to the left.
c) Slide the power supply into the system until the latch (B) locks in place.
d) Repeat steps “2.a” on page 69 - “2.c” on page 69 for the other power supply.
Removing and replacing parts in the 9183-22X 69