2. Identify the part and the system that you are working on. For instructions, see Identifying a
part (www.ibm.com/support/knowledgecenter/POWER9/p9haj/sal.htm).
Use the blue identify LED on the enclosure to locate the system. Ensure that the serial number of the
system matches the serial number to be serviced.
3. Use the blue LED to identify the server.
Ensure that the serial number of the system matches the serial number to be serviced.
4. Label and disconnect the power cords from the system unit.
See Figure 95 on page 99 or Figure 96 on page 100.
Notes:
• This system might be equipped with two or more power supplies. If the removing and replacing
procedures require the system power to be turned off, ensure that all the power sources to the
system are disconnected.
• The power cord (B) is fastened to the system with hook-and-loop fastener (A). If you are placing the
system in a service position after you disconnect the power cords, ensure that you unstrap the
fastener.
Figure 95. Removing the power cords from a rack-mounted server
Control panel cables for the 9009-41A, 9009-42A, or 9223-42H 99
Summary of Contents for Power System 9009-41A
Page 1: ...Power Systems Control panel for the 9009 41A 9009 42A or 9223 42H IBM ...
Page 4: ...iv ...
Page 14: ...xiv Power Systems Power Systems Control panel ...
Page 20: ...or or or 6 Power Systems Power Systems Control panel ...
Page 64: ...Figure 48 Locking the front door 50 Power Systems Power Systems Control panel ...
Page 68: ...or or or 54 Power Systems Power Systems Control panel ...
Page 115: ...or or or Control panel cables for the 9009 41A 9009 42A or 9223 42H 101 ...
Page 158: ...144 Power Systems Power Systems Control panel ...
Page 169: ......
Page 170: ...IBM ...