ports can be used, but not both. IBM i can continue to use a system port for

communication to a UPS even with an HMC attached.

• The integrated system ports are supported for modem and asynch terminal

connections by AIX or Linux. Any other application using serial ports requires a

serial port adapter to be installed in a PCI slot. The integrated system ports do
not support HACMP

TM

 configurations. IBM i only supports the use of the system

ports for attachment to a UPS.

Hardware management console (HMC) machine code

An HMC or IVM is required to manage POWER7 processor-based servers

implementing partitioning. Multiple POWER7 processor-based servers can be

supported by a single HMC.

If an HMC is used to manage any POWER7 processor-based server, the HMC must be

a CR3, or later, model rack-mount HMC or C05, or later, deskside HMC.

If attaching an HMC to a new server or adding function to an existing server that

requires a firmware update, the HMC machine code may need to be updated.

To determine the HMC machine code level required for the firmware level on any

server, go to the following Web page to access the Fix Level Recommendation Tool

(FLRT) on or after the planned availability date for this product. FLRT will identify the

correct HMC machine code for the selected system firmware level

https://www14.software.ibm.com/webapp/set2/sas/f/hmc/home.html

If a single HMC is attached to multiple servers, the HMC machine code level must be

updated to the server with the most recent firmware level. All prior levels of server

firmware are supported with the latest HMC machine code level.

When IBM Systems Director is used to manage an HMC or if the HMC manages more

than 254 partitions, the HMC should have 3 GB of RAM minimum and be CR3 model,

or later, rack-mount or C06, or later, deskside.

Boot requirements

• Selection of feature 0837 will indicate boot from SAN.
• If IBM i (#2145) is selected as the primary operating system and SAN boot is

not selected (#0837), one of the following Load/Source specify codes must be

specified:

– #0724 -- #1996 (177 GB 1.8" SSD) Load Source Specify
– #0727 -- Remote Load Source Specify in #5886
– #0840 -- #3678 (283.7 GB 15K RPM HDD) Load Source Specify
– #0844 -- #3658 (428 GB 15K RPM HDD) Load Source Specify
– #0851 -- #1884 (69.7 GB 15K RPM SFF HDD) Load Source Specify
– #0853 -- #1888 (138 GB 15K RPM SFF HDD) Load Source Specify
– #0854 -- #1909 (69 GB SFF SSD) Load Source Specify
– #0856 -- #1911 (283 GB 10K RPM SFF HDD) Load Source Specify

• If IBM i (#2145) is selected, one of the following system console specify codes

must be selected:

– #5550 -- System Console on HMC
– #5553 -- System Console - Internal LAN

Processor modules

• One or two processor modules are required on an order with four, six, or

eight processor cores on the processor module. A minimum/maximum of one

processor module is required on a Power 710 order and a minimum/maximum of

two processor modules is required on a Power 730 order.

• All processors must be activated.

Summary of Contents for POWER 710

Page 1: ...SVs that can set your business apart from the competition all in a 2U rack mount package Powerful 64 bit 4 core 6 core and 8 core POWER7 processor modules 4 core 6 core and 8 core configurations on th...

Page 2: ...e optional memory riser cards allowing for a maximum system memory of 128 GB Memory features two memory DIMMs per feature supported are 8 GB and 16 GB and run at speeds of 1066 MHz Also the optional A...

Page 3: ...e updates available from Novell to enable all planned functionality SUSE Linux Enterprise Server 10 Service Pack 3 for the Power 710 and Power 730 Express Servers or later with current maintenance upd...

Page 4: ...ual port SFP 10 Gb HEA Copper TwinAx Four PCIe x8 Low Profile slots One GX slot on the Power 710 two GX slots on the Power 730 Integrated Service Processor EnergyScale technology Hot swap and redundan...

Page 5: ...ssis 9300 97xx Language Group Specify 2145 Primary Operating System Indicator IBM i 0040 Mirrored System Disk Level Specify Code 0566 or 0567 IBM i 6 1 1 or IBM i 7 1 indicator 5550 System Console on...

Page 6: ...S port 1832 Quad port RJ45 1 Gb HEA 2 x 5603 Power Supply 1725 Watt AC 7318 Two Processor Chassis 9300 97xx Language Group Specify 2145 Primary Operating System Indicator IBM i 0040 Mirrored System Di...

Page 7: ...rchase the system with no operating system The AIX IBM i or Linux operating system is processed via a feature number on AIX 5 3 6 1 or 7 1 IBM i 6 1 1 or IBM i 7 1 and SUSE Linux Enterprise Server or...

Page 8: ...lifies the order as an IBM Edition and the no charge processor activations are then removed Multiple sample POWER7 IBM Edition configurations are provided in the IBM internal configurator tool includi...

Page 9: ...software media and publications to be shipped to the customer When ordering feature number 5227 or 5228 as an MES an activation key will be posted on an IBM Web site and the customer must retrieve it...

Page 10: ...the EXP12S via SAS cables The SAS cable will vary depending upon the adapter being used the operating system being used and the protection desired The large cache PCI X feature 5904 5908 uses a SAS Y...

Page 11: ...ered separately with the feature 0553 Order the feature 0553 only when required to support rack integration of MES orders prior to shipment from IBM IBM Power Systems Deployment ready Services IBM off...

Page 12: ...features include scrubbing to detect errors a means to call for the deallocation of memory pages for a pattern of correctable errors detected and signaling deallocation of a logical memory block when...

Page 13: ...e system for a number of faults after which the failing core is dynamically deconfigured and called out for replacement These systems are designed to avoid a full system outage POWER7 single processor...

Page 14: ...r an IBM representative or an authorized warranty service provider The serviceability features delivered in this system provide a highly efficient service environment by incorporating the following at...

Page 15: ...ause of the fault will be captured without the need to re create the problem or run any sort of extending tracing or diagnostics program For the vast majority of faults a good FFDC design means that t...

Page 16: ...n and serviceability direction of components Some serviceable parts such as latches levers and touch points need to be pulled or pushed in a certain direction and certain order for the mechanical mech...

Page 17: ...ower boundary and does not require resources from a system processor to be operational to perform its tasks The Service Processor supports surveillance of the connection to the HMC and to the system f...

Page 18: ...only flows one way activating Service Agent does not enable IBM to call into a customer s system System inventory information is stored in a secure database which is protected behind IBM firewalls The...

Page 19: ...sion The information mentioned regarding potential future products is not a commitment promise or legal obligation to deliver any material code or functionality Information about potential future prod...

Page 20: ...B 1010 Modem Cable Belgium 8231 E2B 1011 Modem Cable Africa 8231 E2B 1012 Modem Cable Israel 8231 E2B 1013 Modem Cable Italy 8231 E2B 1014 Modem Cable France 8231 E2B 1015 Modem Cable Germany 8231 E2B...

Page 21: ...l Monitor 8231 E2B 3639 ThinkVision L171p Flat Panel Monitor 8231 E2B 3640 IBM T115 Flat Panel Monitor 8231 E2B 3641 ThinkVision L191p Flat Panel Monitor 8231 E2B 3642 IBM T120 Flat Panel Monitor 8231...

Page 22: ...t 3 Phase 8231 E2B 5163 PowerVM Express Edition 8231 E2B 5225 PowerVM Standard Edition 8231 E2B 5227 PowerVM Enterprise Edition 8231 E2B 5228 Storage Backplane 3 SFF Drives SATA DVD HH Tape 8231 E2B 5...

Page 23: ...Acoustic Doors 8231 E2B 6249 1 8m Rack Trim Kit 8231 E2B 6263 2 0m Rack Trim Kit 8231 E2B 6272 Power Cable Drawer to IBM PDU 14 foot 250V 10A 8231 E2B 6458 Power Cord 4 3m 14 ft Drawer To OEM PDU 125...

Page 24: ...onsole to System Unit 8231 E2B 7802 Side by Side for 1 8m Racks 8231 E2B 7840 Ruggedize Rack Kit 8231 E2B 7841 Linux Software Preinstall 8231 E2B 8143 Linux Software Preinstall Business Partners 8231...

Page 25: ...B 9724 Language Group Specify Romanian 8231 E2B 9725 Language Group Specify Croatian 8231 E2B 9726 Language Group Specify Slovenian 8231 E2B 9727 Language Group Specify Brazilian Portuguese 8231 E2B 9...

Page 26: ...M Systems Information Center provides you with a single information center where you can access product documentation for IBM systems hardware operating systems and server software Through a consisten...

Page 27: ...to 80 F allowable operating temperature 5 to 35 C 41 to 95 F Relative humidity Nonoperating 8 to 80 recommended 5 5 C 42 F dew point to 60 RH and 15 C 59 F dew point Maximum dew point 28 C 84 F operat...

Page 28: ...tion UL 60950 Underwriters Laboratory Safety Information CSA C22 2 No 60950 00 Canadian Standards Association EN60950 European Norm IEC 60950 Edition 1 International Electrotechnical Commission Safety...

Page 29: ...8349 16 x 8372 or 8 x 8372 and 8 x 8375 with processor card 8359 Notes Features 8363 8375 8383 and 8384 are part of IBM Editions Processor activations are only available to SDIs as MES orders Choose...

Page 30: ...rotected This HDD SSD drive protection can be provided by AIX IBM i Linux software or by the HDD SSD hardware controllers Mirroring of drives is provided by AIX IBM i Linux software In addition AIX Li...

Page 31: ...Enterprise Server 10 Service Pack 3 for the Power 710 and Power 730 Express Servers or later with current maintenance updates available from Novell to enable all planned functionality Red Hat Enterpr...

Page 32: ...system firmware level https www14 software ibm com webapp set2 sas f hmc home html If a single HMC is attached to multiple servers the HMC machine code level must be updated to the server with the mos...

Page 33: ...ly System memory A minimum 8 GB or two DIMMs of memory is required on the Power 710 and Power 730 systems The base machine contains one nonfeaturized memory riser card with four DIMM sockets Memory fe...

Page 34: ...nd the correct interface to use for each of the drawers Feature Order number Description status Interface 5886 Exp 12S SAS Disk Drawer Available SAS PCI card slots The Power 710 and Power 730 contain...

Page 35: ...1884 1885 1886 1888 1890 1909 or 1911 must be selected no HDDs SSDs are required in the CEC if feature number 0837 is selected Disk units can be placed in any slot at any time with or without a split...

Page 36: ...7 GB SAS 1 8 8 0 8 1995 Solid state 8 in 2 x 2053 177 GB SAS 1 8 0 8 0 1996 Solid state 8 in 2 x 2053 Note Six disks or solid state drives maximum can be installed internally Orderable Maximum feature...

Page 37: ...ty esa_main and select Configure Electronic Service Agent In addition ESA now includes a powerful Web user interface giving the administrator easy access to status tool settings problem information an...

Page 38: ...www ibm com support electronic Terms and conditions Volume orders Contact your IBM representative Warranty period Three years Alternative warranty options are available on a special bid basis from yo...

Page 39: ...affle Fan All PCI Adapters Power Supply Adapter GX Line power cord Keyboard Mouse External cables Display Operator Panel TOD Battery Memory DIMMs Processor VRM SAS Conduit Cable USB Tape Drive Cable U...

Page 40: ...BM installation at no additional charge under one of the On site Service levels specified above For additional information on the CRU Service see warranty information Maintenance services If required...

Page 41: ...able Unit Service is available in your geography Refer to the information above for On site Service Below you will find additional information pertaining to CRU Service available for your product CRUs...

Page 42: ...k drives and memory installed within IBM machines covered under warranty service upgrades or maintenance services and provides the labor to replace the failing parts at no additional charge If IBM has...

Page 43: ...l downloadable machine code changes however you may be charged for that service Europe Business Partner terms and conditions EMEA Business Partner Terms and Conditions For more information Business Pa...

Page 44: ...sions worldwide to qualified commercial and government customers For all customer segments offerings rates financing terms offering type equipment type and options may vary by country Other restrictio...

Page 45: ...G10 0214 IBM is a registered trademark of International Business Machines Corporation 45 For the most current information regarding IBM products consult your IBM representative or reseller or visit th...

Reviews: