background image

IBM Europe, Middle East, and Africa Hardware

Announcement ZG10-0214

IBM is a registered trademark of International Business Machines Corporation

15

a clear, concise view of available service applications, the Service Interface allows

the support team to manage system resources and service information in an

efficient and effective way. Applications available via the Service Interface are

carefully configured and placed to give service providers access to important service

functions.

Different service interfaces are used, depending on the state of the system and its

operating environment. The primary service interfaces are:

• LEDs
• Operator Panel
• Service Processor menu
• Operating system service menu
• Service Focal Point

TM

 on the HMC

• Service Focal Point Lite on IVM

In the light path LED implementation, the system can clearly identify components

for replacement by using specific component-level LEDs, and can also guide the

servicer directly to the component by signaling (turning on solid) the amber system

fault LED, enclosure fault LED, and the component FRU fault LED. The servicer

can also use the identify function to blink the FRU-level LED. When this function is

activated, a roll-up to the blue enclosure locate and system locate LEDs will occur.

These LEDs will turn on solid and can be used to follow the light path from the

system to the enclosure and down to the specific FRU.

First Failure Data Capture and Error Data Analysis

First Failure Data Capture (FFDC) is a technique that helps ensure that when a fault

is detected in a system, the root cause of the fault will be captured without the

need to re-create the problem or run any sort of extending tracing or diagnostics

program. For the vast majority of faults, a good FFDC design means that the root

cause can also be detected automatically without servicer intervention.

First Failure Data Capture FFDC information, error data analysis, and fault isolation

are necessary to implement the advanced serviceability techniques that enable

efficient service of the systems and to help determine the failing items.

In the rare absence of FFDC and Error Data Analysis, diagnostics are required to re-

create the failure and determine the failing items.

Diagnostics

General diagnostic objectives are to detect and identify problems such that they can

be resolved quickly. Elements of IBM's diagnostics strategy include:

• Provide a common error code format equivalent to a system reference code,

system reference number, checkpoint, or firmware error code.

• Provide fault detection and problem isolation procedures. Support remote

connection ability to be used by the IBM Remote Support Center or IBM

Designated Service.

• Provide interactive intelligence within the diagnostics with detailed online failure

information while connected to IBM's back-end system.

Automatic diagnostics

Because of the FFDC technology designed into IBM Servers, it is not necessary to

perform re-create diagnostics for failures or require user intervention. Solid and

intermittent errors are designed to be correctly detected and isolated at the time the

failure occurs. Runtime and boot-time diagnostics fall into this category.

Stand-alone diagnostics

As the name implies, stand-alone or user-initiated diagnostics require user

intervention. The user must perform manual steps, including:

Summary of Contents for POWER 710

Page 1: ...SVs that can set your business apart from the competition all in a 2U rack mount package Powerful 64 bit 4 core 6 core and 8 core POWER7 processor modules 4 core 6 core and 8 core configurations on th...

Page 2: ...e optional memory riser cards allowing for a maximum system memory of 128 GB Memory features two memory DIMMs per feature supported are 8 GB and 16 GB and run at speeds of 1066 MHz Also the optional A...

Page 3: ...e updates available from Novell to enable all planned functionality SUSE Linux Enterprise Server 10 Service Pack 3 for the Power 710 and Power 730 Express Servers or later with current maintenance upd...

Page 4: ...ual port SFP 10 Gb HEA Copper TwinAx Four PCIe x8 Low Profile slots One GX slot on the Power 710 two GX slots on the Power 730 Integrated Service Processor EnergyScale technology Hot swap and redundan...

Page 5: ...ssis 9300 97xx Language Group Specify 2145 Primary Operating System Indicator IBM i 0040 Mirrored System Disk Level Specify Code 0566 or 0567 IBM i 6 1 1 or IBM i 7 1 indicator 5550 System Console on...

Page 6: ...S port 1832 Quad port RJ45 1 Gb HEA 2 x 5603 Power Supply 1725 Watt AC 7318 Two Processor Chassis 9300 97xx Language Group Specify 2145 Primary Operating System Indicator IBM i 0040 Mirrored System Di...

Page 7: ...rchase the system with no operating system The AIX IBM i or Linux operating system is processed via a feature number on AIX 5 3 6 1 or 7 1 IBM i 6 1 1 or IBM i 7 1 and SUSE Linux Enterprise Server or...

Page 8: ...lifies the order as an IBM Edition and the no charge processor activations are then removed Multiple sample POWER7 IBM Edition configurations are provided in the IBM internal configurator tool includi...

Page 9: ...software media and publications to be shipped to the customer When ordering feature number 5227 or 5228 as an MES an activation key will be posted on an IBM Web site and the customer must retrieve it...

Page 10: ...the EXP12S via SAS cables The SAS cable will vary depending upon the adapter being used the operating system being used and the protection desired The large cache PCI X feature 5904 5908 uses a SAS Y...

Page 11: ...ered separately with the feature 0553 Order the feature 0553 only when required to support rack integration of MES orders prior to shipment from IBM IBM Power Systems Deployment ready Services IBM off...

Page 12: ...features include scrubbing to detect errors a means to call for the deallocation of memory pages for a pattern of correctable errors detected and signaling deallocation of a logical memory block when...

Page 13: ...e system for a number of faults after which the failing core is dynamically deconfigured and called out for replacement These systems are designed to avoid a full system outage POWER7 single processor...

Page 14: ...r an IBM representative or an authorized warranty service provider The serviceability features delivered in this system provide a highly efficient service environment by incorporating the following at...

Page 15: ...ause of the fault will be captured without the need to re create the problem or run any sort of extending tracing or diagnostics program For the vast majority of faults a good FFDC design means that t...

Page 16: ...n and serviceability direction of components Some serviceable parts such as latches levers and touch points need to be pulled or pushed in a certain direction and certain order for the mechanical mech...

Page 17: ...ower boundary and does not require resources from a system processor to be operational to perform its tasks The Service Processor supports surveillance of the connection to the HMC and to the system f...

Page 18: ...only flows one way activating Service Agent does not enable IBM to call into a customer s system System inventory information is stored in a secure database which is protected behind IBM firewalls The...

Page 19: ...sion The information mentioned regarding potential future products is not a commitment promise or legal obligation to deliver any material code or functionality Information about potential future prod...

Page 20: ...B 1010 Modem Cable Belgium 8231 E2B 1011 Modem Cable Africa 8231 E2B 1012 Modem Cable Israel 8231 E2B 1013 Modem Cable Italy 8231 E2B 1014 Modem Cable France 8231 E2B 1015 Modem Cable Germany 8231 E2B...

Page 21: ...l Monitor 8231 E2B 3639 ThinkVision L171p Flat Panel Monitor 8231 E2B 3640 IBM T115 Flat Panel Monitor 8231 E2B 3641 ThinkVision L191p Flat Panel Monitor 8231 E2B 3642 IBM T120 Flat Panel Monitor 8231...

Page 22: ...t 3 Phase 8231 E2B 5163 PowerVM Express Edition 8231 E2B 5225 PowerVM Standard Edition 8231 E2B 5227 PowerVM Enterprise Edition 8231 E2B 5228 Storage Backplane 3 SFF Drives SATA DVD HH Tape 8231 E2B 5...

Page 23: ...Acoustic Doors 8231 E2B 6249 1 8m Rack Trim Kit 8231 E2B 6263 2 0m Rack Trim Kit 8231 E2B 6272 Power Cable Drawer to IBM PDU 14 foot 250V 10A 8231 E2B 6458 Power Cord 4 3m 14 ft Drawer To OEM PDU 125...

Page 24: ...onsole to System Unit 8231 E2B 7802 Side by Side for 1 8m Racks 8231 E2B 7840 Ruggedize Rack Kit 8231 E2B 7841 Linux Software Preinstall 8231 E2B 8143 Linux Software Preinstall Business Partners 8231...

Page 25: ...B 9724 Language Group Specify Romanian 8231 E2B 9725 Language Group Specify Croatian 8231 E2B 9726 Language Group Specify Slovenian 8231 E2B 9727 Language Group Specify Brazilian Portuguese 8231 E2B 9...

Page 26: ...M Systems Information Center provides you with a single information center where you can access product documentation for IBM systems hardware operating systems and server software Through a consisten...

Page 27: ...to 80 F allowable operating temperature 5 to 35 C 41 to 95 F Relative humidity Nonoperating 8 to 80 recommended 5 5 C 42 F dew point to 60 RH and 15 C 59 F dew point Maximum dew point 28 C 84 F operat...

Page 28: ...tion UL 60950 Underwriters Laboratory Safety Information CSA C22 2 No 60950 00 Canadian Standards Association EN60950 European Norm IEC 60950 Edition 1 International Electrotechnical Commission Safety...

Page 29: ...8349 16 x 8372 or 8 x 8372 and 8 x 8375 with processor card 8359 Notes Features 8363 8375 8383 and 8384 are part of IBM Editions Processor activations are only available to SDIs as MES orders Choose...

Page 30: ...rotected This HDD SSD drive protection can be provided by AIX IBM i Linux software or by the HDD SSD hardware controllers Mirroring of drives is provided by AIX IBM i Linux software In addition AIX Li...

Page 31: ...Enterprise Server 10 Service Pack 3 for the Power 710 and Power 730 Express Servers or later with current maintenance updates available from Novell to enable all planned functionality Red Hat Enterpr...

Page 32: ...system firmware level https www14 software ibm com webapp set2 sas f hmc home html If a single HMC is attached to multiple servers the HMC machine code level must be updated to the server with the mos...

Page 33: ...ly System memory A minimum 8 GB or two DIMMs of memory is required on the Power 710 and Power 730 systems The base machine contains one nonfeaturized memory riser card with four DIMM sockets Memory fe...

Page 34: ...nd the correct interface to use for each of the drawers Feature Order number Description status Interface 5886 Exp 12S SAS Disk Drawer Available SAS PCI card slots The Power 710 and Power 730 contain...

Page 35: ...1884 1885 1886 1888 1890 1909 or 1911 must be selected no HDDs SSDs are required in the CEC if feature number 0837 is selected Disk units can be placed in any slot at any time with or without a split...

Page 36: ...7 GB SAS 1 8 8 0 8 1995 Solid state 8 in 2 x 2053 177 GB SAS 1 8 0 8 0 1996 Solid state 8 in 2 x 2053 Note Six disks or solid state drives maximum can be installed internally Orderable Maximum feature...

Page 37: ...ty esa_main and select Configure Electronic Service Agent In addition ESA now includes a powerful Web user interface giving the administrator easy access to status tool settings problem information an...

Page 38: ...www ibm com support electronic Terms and conditions Volume orders Contact your IBM representative Warranty period Three years Alternative warranty options are available on a special bid basis from yo...

Page 39: ...affle Fan All PCI Adapters Power Supply Adapter GX Line power cord Keyboard Mouse External cables Display Operator Panel TOD Battery Memory DIMMs Processor VRM SAS Conduit Cable USB Tape Drive Cable U...

Page 40: ...BM installation at no additional charge under one of the On site Service levels specified above For additional information on the CRU Service see warranty information Maintenance services If required...

Page 41: ...able Unit Service is available in your geography Refer to the information above for On site Service Below you will find additional information pertaining to CRU Service available for your product CRUs...

Page 42: ...k drives and memory installed within IBM machines covered under warranty service upgrades or maintenance services and provides the labor to replace the failing parts at no additional charge If IBM has...

Page 43: ...l downloadable machine code changes however you may be charged for that service Europe Business Partner terms and conditions EMEA Business Partner Terms and Conditions For more information Business Pa...

Page 44: ...sions worldwide to qualified commercial and government customers For all customer segments offerings rates financing terms offering type equipment type and options may vary by country Other restrictio...

Page 45: ...G10 0214 IBM is a registered trademark of International Business Machines Corporation 45 For the most current information regarding IBM products consult your IBM representative or reseller or visit th...

Reviews: