Netfinity EXP300 Type 3531
19
3. Determine the bay into which you want to install the drive.
4. Remove the filler panel.
a. Insert a finger into the square hole at the top of the filler panel to grip and pull
the panel out of the drive bay.
b. Save the filler panel for later use.
5. Install the drive CRU:
Note:
The hard disk drive comes with a tray already attached. Do not attempt
to detach the drive
Þ
4
Ý
from the tray
Þ
3
Ý
.
a. Release the blue latch
Þ
1
Ý
on the drive CRU by pressing on the inside of the
bottom of the tray handle
Þ
2
Ý
.
b. Pull the handle
Þ
2
Ý
on the tray out into the open position.
c. Slide the drive CRU into the empty bay until the tray handle
Þ
2
Ý
touches the
expansion-unit bezel.
d. Push the tray handle
Þ
2
Ý
down into the closed (latched) position.
6. Check the drive LEDs.
a. When a drive is ready for use, the green activity LED and the amber fault
LED are off.
b. If the amber fault LED is on, remove the drive from the unit and wait 10
seconds; then, reinstall the drive.
7. Configure the drive using the appropriate software.
ServeRAID information
In some cases, the ServeRAID controller will automatically reset the drive to the
Hot Spare or Rebuild state. If the drive state change does not occur automatically
(amber LED stays lit), refer to your ServeRAID documentation for information
about manually changing the state of the drive from the current state to another
state, such as Hot Spare or Ready. The amber LED should turn off within 10
seconds after the drive-state change.
Summary of Contents for Netfinity EXP300
Page 1: ...IBM IBM Netfinity EXP300 Type 3531 Hardware Maintenance Manual...
Page 2: ......
Page 3: ...IBM IBM Netfinity EXP300 Type 3531 Hardware Maintenance Manual...
Page 8: ...vi IBM Netfintiy EXP300 Type 3531 Hardware Maintenance Manual...
Page 48: ...40 IBM Netfinity EXP300 Type 3531 Hardware Maintenance Manual...
Page 61: ...Chapter 2 Related service information 53...
Page 62: ...54 IBM Netfinity EXP300 Type 3531 Hardware Maintenance Manual...
Page 63: ...Chapter 2 Related service information 55...
Page 64: ...56 IBM Netfinity EXP300 Type 3531 Hardware Maintenance Manual...
Page 65: ...Chapter 2 Related service information 57...
Page 66: ...58 IBM Netfinity EXP300 Type 3531 Hardware Maintenance Manual...
Page 67: ...Chapter 2 Related service information 59...
Page 68: ...60 IBM Netfinity EXP300 Type 3531 Hardware Maintenance Manual...
Page 81: ...Chapter 2 Related service information 73...
Page 82: ...74 IBM Netfinity EXP300 Type 3531 Hardware Maintenance Manual...
Page 83: ...Chapter 2 Related service information 75...
Page 91: ......
Page 93: ...IBM...