4.
Place the FIB (shown in Figure 124) in a safe location.
5.
If needed, repeat steps 2 on page 126 through 3 on page 127 to remove the
other FIB.
Replace the fan interface board
6.
To reinstall a fan interface board, or replace it with one from FRU stock, follow
the procedure in “Installing or replacing a fan interface board: 2145-92F” on
page 101.
Replacing an enclosure: 2145-92F
You can replace a faulty enclosure (FRU 01LJ112) of a 2145-92F expansion
enclosure with a new one from FRU stock.
Before you begin
DANGER
Multiple power cords. The product might be equipped with multiple power
cords. To remove all hazardous voltages, disconnect all power cords. (L003)
(L003)
1
3
2
4
or
sv100128
svc01019
Figure 124. FIB parts removed from the chassis
128
SAN Volume Controller: Model 2145-SV1 Hardware Installation Guide
Summary of Contents for MTM 2145-12F
Page 8: ...viii SAN Volume Controller Model 2145 SV1 Hardware Installation Guide...
Page 26: ...xxvi SAN Volume Controller Model 2145 SV1 Hardware Installation Guide...
Page 72: ...38 SAN Volume Controller Model 2145 SV1 Hardware Installation Guide...
Page 192: ...158 SAN Volume Controller Model 2145 SV1 Hardware Installation Guide...
Page 194: ...160 SAN Volume Controller Model 2145 SV1 Hardware Installation Guide...
Page 196: ...162 SAN Volume Controller Model 2145 SV1 Hardware Installation Guide...
Page 200: ...166 SAN Volume Controller Model 2145 SV1 Hardware Installation Guide...
Page 208: ...174 SAN Volume Controller Model 2145 SV1 Hardware Installation Guide...
Page 212: ...178 SAN Volume Controller Model 2145 SV1 Hardware Installation Guide...
Page 213: ......
Page 214: ...IBM Printed in USA GI13 4547 02...