Connect and test power to the drive
About this task
The drive does not contain its own power source; it must be powered externally.
To connect and test power to the drive, complete the following steps:
1.
Ensure that the enclosure (or unit that supplies power to the drive) is powered
off.
2.
Ensure that the power cord is disconnected from both the enclosure and the
power outlet.
3.
Connect the enclosure internal power cable to the power connector on the drive
(see
2
in “Rear view of the drive” on page 2).
4.
Connect the power cord to the enclosure and to the electrical outlet.
5.
Review the location of the single-character display (SCD) and the status LED in
Figure 2 on page 2. To ensure that the drive is receiving power, watch for the
following while turning on the power to the enclosure:
v
During the power-on/initialization and POST (Power-On Self Test), the SCD
briefly displays
8
, then becomes blank (not lit) when POST is complete and there are no POST
errors. If a POST error has been detected, an error code will be displayed in
the SCD and the status LED will flash amber.
Drive
2.5mm (0.10 in.)
MAXIMUM Penetration
Depth From OUTSIDE
of Drive
Drive
Air Intake Area
Upper Side Mounting Holes
Lower Side Mounting Holes
5.0mm (0.20 in.)
MAXIMUM Penetration
Depth From OUTSIDE
of Drive
Figure 5. Mounting holes on the drive.
The holes are located on both sides of the drive. The drive is shown with a
front bezel.
8
LTO Ultrium 4 Half High Tape Drive
Summary of Contents for LTO Ultrium 4
Page 2: ......
Page 3: ...IBM LTO Ultrium 4 Half High Tape Drive Installation and User s Guide ...
Page 10: ...viii LTO Ultrium 4 Half High Tape Drive ...
Page 14: ...xii LTO Ultrium 4 Half High Tape Drive ...
Page 16: ...xiv LTO Ultrium 4 Half High Tape Drive ...
Page 80: ...64 LTO Ultrium 4 Half High Tape Drive ...
Page 82: ...66 LTO Ultrium 4 Half High Tape Drive ...
Page 88: ...72 LTO Ultrium 4 Half High Tape Drive ...
Page 91: ......
Page 92: ... Part Number 60Y1485 Printed in USA 1P P N 60Y1485 ...