v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
to
determine
which
components
are
CRUs
and
which
components
are
FRUs.
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
code
Description
Action
089-xxx-00n
Failed
microprocessor
test.
1.
(Trained
service
technician
only)
Reseat
microprocessor
1
if
n
=
0
or
6.
2.
(Trained
service
technician
only)
Reseat
microprocessor
2
if
n
=
1
or
7.
3.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
blade
server
each
time:
a.
(Trained
service
technician
only)
Microprocessor
1
if
n
=
0
or
6
b.
(Trained
service
technician
only)
Microprocessor
2
if
n
=
1
or
7
c.
(Trained
service
technician
only)
System
board
assembly
166-403-001
System
Management:
Failed
(BMC
indicates
failure
in
I2C
bus
test)
Shutdown
and
remove
the
blade
server
from
the
BladeCenter
unit,
wait
30
seconds;
then,
reinstall
the
blade
server
in
the
BladeCenter
unit
and
restart
it.
If
problem
persists,
perform
the
following
tasks
in
the
order
shown,
restarting
the
blade
server
each
time:
1.
Remove
the
cKVM
feature
card
(if
installed).
2.
Update
the
BMC
firmware.
3.
Update
the
Ethernet
controller
firmware.
4.
(Trained
service
technician
only)
Replace
the
system
board
assembly.
166-404-001
System
Management:
Failed
(BMC
indicates
failure
in
I2C
bus
test)
Shutdown
and
remove
the
blade
server
from
the
BladeCenter
unit,
wait
30
seconds;
then,
reinstall
the
blade
server
in
the
BladeCenter
unit
and
restart
it.
If
problem
persists,
perform
the
following
tasks
in
the
order
shown,
restarting
the
blade
server
each
time:
1.
Update
the
BMC
firmware.
2.
(Trained
service
technician
only)
Replace
the
system
board
assembly.
166-405-001
System
Management:
Failed
(BMC
indicates
failure
in
I2C
bus
test)
Shutdown
and
remove
the
blade
server
from
the
BladeCenter
unit,
wait
30
seconds;
then,
reinstall
the
blade
server
in
the
BladeCenter
unit
and
restart
it.
If
problem
persists,
perform
the
following
tasks
in
the
order
shown,
restarting
the
blade
server
each
time:
1.
Remove
the
cKVM
feature
card
(if
present).
2.
Update
the
BMC
firmware.
3.
(Trained
service
technician
only)
Replace
the
system
board
assembly.
Chapter
2.
Diagnostics
59
Summary of Contents for HS21 - BladeCenter - 8853
Page 1: ...BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Page 8: ...vi BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Page 16: ...xiv BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Page 126: ...110 BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Page 138: ...122 BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Page 139: ......
Page 140: ...Part Number 24R9701 Printed in USA 1P P N 24R9701...