v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
to
determine
which
components
are
CRUs
and
which
components
are
FRUs.
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Beep
code
Description
Action
1-1-4
BIOS
ROM
checksum
failed.
1.
Update
the
BIOS
code.
2.
Reseat
the
DIMMs.
3.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
blade
server
each
time:
a.
DIMMs
b.
(Trained
service
technician
only)
System
board
assembly
1-2-1
Programmable
interval
timer
failed.
(Trained
service
technician
only)
Replace
the
system
board
assembly.
1-2-2
DMA
initialization
failed.
(Trained
service
technician
only)
Replace
the
system
board
assembly.
1-2-3
DMA
page
register
write/read
failed.
(Trained
service
technician
only)
Replace
the
system
board
assembly.
1-2-4
RAM
refresh
verification
failed.
1.
Reseat
the
DIMMs
and
the
Memory
and
I/O
Expansion
Blade
if
installed.
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
blade
server
each
time:
a.
DIMMs
b.
(Trained
service
technician
only)
System
board
assembly
c.
Memory
and
I/O
Expansion
Blade
(if
one
is
installed)
1-3-1
First
64K
RAM
test
failed.
1.
Reseat
the
DIMMs.
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
blade
server
each
time:
a.
DIMMs
b.
(Trained
service
technician
only)
System
board
assembly
1-3-2
First
64K
RAM
parity
test
failed.
1.
Reseat
the
DIMMs.
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
blade
server
each
time:
a.
DIMMs
b.
(Trained
service
technician
only)
System
board
assembly
2-1-1
Secondary
DMA
register
test
failed.
(Trained
service
technician
only)
Replace
the
system
board
assembly.
2-1-2
Primary
DMA
register
test
failed.
(Trained
service
technician
only)
Replace
the
system
board
assembly.
Chapter
2.
Diagnostics
13
Summary of Contents for HS21 - BladeCenter - 8853
Page 1: ...BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Page 8: ...vi BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Page 16: ...xiv BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Page 126: ...110 BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Page 138: ...122 BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Page 139: ......
Page 140: ...Part Number 24R9701 Printed in USA 1P P N 24R9701...