Status LEDs for the QSFP+ ports are described in the following table. When the
port is 40 GbE mode, only the first LED applies. When the port is in 10 GbE mode,
each LED provides status for its corresponding 10 GbE port, as noted in the
following table.
Table 8. SFP+ LEDs status
Steady green
Flash green
Off
Valid link
Activity
No Link
Technical specifications
The RackSwitch technical specifications are described in the following sections.
Physical characteristics
The physical characteristics of the RackSwitch are listed in the following table.
Table 9. Physical characteristics
Specification
Physical characteristics
Dimensions (H x W x D)
4.4 x 43.9 x 51.3 cm.
(1.73 x 17.3 x 20.2 in.)
Weight
10.5 kg. (23 lb) (maximum)
Environmental specifications
The environmental specifications for the RackSwitch are listed in the following table.
Table 10. Environmental specifications
Specification
Measurement
Temperature, ambient operating
0°C to +40°C (32° to 104°F)
Temperature (fan failure), operating
0°C to +35°C (32° to 95°F)
Temperature, storage
-40°C to +85°C (-40° to 185°F)
Relative humidity (non-condensing),
operating
10 to 90%
Relative humidity (non-condensing), storage
10 to 90%
Altitude, operating
1,800 m (6,000 feet)
Altitude, storage
12,190 m (40,000 feet)
Acoustic noise
Less than 65dB
Heat dissipation
955 BTU/hour (typical)
1262 BTU/hour (maximum)
Power specifications
The power specifications for the RackSwitch are listed in the following table.
Table 11. AC power specifications
Specification
Measurement
Number of power supplies
2 (1+1 load sharing/redundant)
AC-input frequency (universal)
50 - 60 Hz
AC-input voltage (universal)
100-240 VAC
10
IBM System Networking RackSwitch G8316, Type 8036 and Type 1611-16E: Installation Guide
Summary of Contents for G8316
Page 1: ...IBM System Networking RackSwitch G8316 Type 8036 and Type 1611 16E Installation Guide...
Page 2: ......
Page 3: ...IBM System Networking RackSwitch G8316 Type 8036 and Type 1611 16E Installation Guide...
Page 14: ...xii IBM System Networking RackSwitch G8316 Type 8036 and Type 1611 16E Installation Guide...
Page 28: ...12 IBM System Networking RackSwitch G8316 Type 8036 and Type 1611 16E Installation Guide...
Page 46: ...30 IBM System Networking RackSwitch G8316 Type 8036 and Type 1611 16E Installation Guide...
Page 64: ...48 IBM System Networking RackSwitch G8316 Type 8036 and Type 1611 16E Installation Guide...
Page 70: ...54 IBM System Networking RackSwitch G8316 Type 8036 and Type 1611 16E Installation Guide...
Page 80: ...64 IBM System Networking RackSwitch G8316 Type 8036 and Type 1611 16E Installation Guide...
Page 83: ......
Page 84: ...Part Number 00AY386 Printed in USA 1P P N 00AY386...