Reset button
The Reset button is recessed within a hole on the front panel. Use a straightened
paper clip or similar object to press the Reset button. The Reset button allows
technicians to reset the switch, as follows:
v
Press Reset: The switch resets and reloads the configuration files.
v
Press and hold Reset for five seconds: The switch resets and configures all
settings to factory defaults.
Fans
Four internal hot-swap fan modules cool the switch unit. If an individual fan module
fails, the other fans continue to run, and the switch unit continues to operate
normally. You can replace a hot-swap fan module while the switch is operating.
Fan operation and internal temperatures are monitored. If the air temperature
exceeds a desired threshold, the environmental monitor displays warning
messages.
If a fan fails, the maximum operating temperature drops from 40
⁰
C to 35
⁰
C (104
⁰
F to 95
⁰
F).
Attention:
The Service ( ! ) LED flashes and the Fan LED flashes if there is a
failure of one or more fan modules. The failed fan module LED (rear panel) flashes
to indicate a failure.
AC power supply
The RackSwitch has two hot-swap redundant 450 W AC power supplies. Each
power supply has an individual IEC 320 power connector on the rear panel. The
power cord attaches to a universal grounded AC power source. You can replace a
hot-swap power supply module without powering off the switch or disrupting switch
functions.
!
S
Mgmt
Reset Button
RS-232 Port
RJ-45 Port
USB Port
System Status LEDs
Figure 2. IBM RackSwitch G8316 front panel detail
OK
~AC
!
OK
~AC
!
Power Supply
Module
Fan Modules
IEC320
Power Connector
IEC320
Power Connector
Power Supply
Module
Figure 3. IBM RackSwitch G8316 rear panel
Chapter 1. Introduction
5
Summary of Contents for G8316
Page 1: ...IBM System Networking RackSwitch G8316 Type 8036 and Type 1611 16E Installation Guide...
Page 2: ......
Page 3: ...IBM System Networking RackSwitch G8316 Type 8036 and Type 1611 16E Installation Guide...
Page 14: ...xii IBM System Networking RackSwitch G8316 Type 8036 and Type 1611 16E Installation Guide...
Page 28: ...12 IBM System Networking RackSwitch G8316 Type 8036 and Type 1611 16E Installation Guide...
Page 46: ...30 IBM System Networking RackSwitch G8316 Type 8036 and Type 1611 16E Installation Guide...
Page 64: ...48 IBM System Networking RackSwitch G8316 Type 8036 and Type 1611 16E Installation Guide...
Page 70: ...54 IBM System Networking RackSwitch G8316 Type 8036 and Type 1611 16E Installation Guide...
Page 80: ...64 IBM System Networking RackSwitch G8316 Type 8036 and Type 1611 16E Installation Guide...
Page 83: ......
Page 84: ...Part Number 00AY386 Printed in USA 1P P N 00AY386...