IBM System Networking RackSwitch G8316, Type 8036
and Type 1611-16E

Installation Guide

Summary of Contents for G8316

Page 1: ...IBM System Networking RackSwitch G8316 Type 8036 and Type 1611 16E Installation Guide...

Page 2: ......

Page 3: ...IBM System Networking RackSwitch G8316 Type 8036 and Type 1611 16E Installation Guide...

Page 4: ...afety Notices document and the License Agreement for Machine Code LAMC document on the IBM Documentation CD Read the IBM Systems Environmental Notices and Users Guide document on the Environmental Not...

Page 5: ...teen lue turvaohjeet kohdasta Safety Information Avant d installer ce produit lisez les consignes de s curit Vor der Installation dieses Produkts die Sicherheitshinweise lesen Prima di installare ques...

Page 6: ...tions for that caution statement are in the Systems Safety Notices document under D005 Be sure to read all caution and danger statements in this document before you perform the procedures Read any add...

Page 7: ...DANGER Multiple power cords The product might be equipped with multiple power cords To remove all hazardous voltages disconnect all power cords L003 1 2 or 1 2 Safety v...

Page 8: ...metal parts of the system or the devices that attach to the system It is the responsibility of the customer to ensure that the outlet is correctly wired and grounded to prevent an electrical shock D0...

Page 9: ...operly wired outlets v When possible use one hand only to connect or disconnect signal cables v Never turn on any equipment when there is evidence of fire water or structural damage v Disconnect the a...

Page 10: ...nd IEC 60950 The Standard for Safety of Information Technology Equipment v Connect the equipment to a reliably grounded safety extra low voltage SELV source An SELV source is a secondary circuit that...

Page 11: ...Table 1 Electrical connections continued Wire size 16 AWG 1 31 mm2 Wiring terminal screw torque v inch pounds v newton meters Nm Safety ix...

Page 12: ...ck mounted devices v Each rack cabinet might have more than one power cord Be sure to disconnect all power cords in the rack cabinet when directed to disconnect power during servicing v Connect all de...

Page 13: ...t in the rack to determine the total power requirement of the supply circuit v For sliding drawers Do not pull out or install any drawer or feature if the rack stabilizer brackets are not attached to...

Page 14: ...xii IBM System Networking RackSwitch G8316 Type 8036 and Type 1611 16E Installation Guide...

Page 15: ...r rack 22 Installing the 1U air duct option in a rack 25 Mounting kit components 25 Installing a QSFP transceiver 28 Chapter 3 Removing and replacing the RackSwitch and components 31 Removing and repl...

Page 16: ...tion regulatory statement 60 Electronic emission notices 60 Federal Communications Commission FCC statement 60 Industry Canada Class A emission compliance statement 60 Avis de conformit la r glementat...

Page 17: ...ight be available to provide additional information that is not included in the switch documentation To check for documentation updates 1 Go to http www ibm com supportportal and click Documentation 2...

Page 18: ...ces and statements are used in this document v Note These notices provide important tips guidance or advice v Important These notices provide information or advice that might help you avoid inconvenie...

Page 19: ...v Layer 2 4096 VLANs 802 1Q including Private VLANs Multi link trunking compatible with Cisco EtherChannel LACP IEEE 802 3ad Spanning Tree 802 1D Multiple Spanning Tree 802 1s Rapid Spanning Tree 802...

Page 20: ...nt to rear provides front to rear airflow v RackSwitch G8316 rear to front provides rear to front airflow Ports The switch unit contains the following ports v Sixteen 40Gb QSFP slots v RJ 45 managemen...

Page 21: ...e environmental monitor displays warning messages If a fan fails the maximum operating temperature drops from 40 C to 35 C 104 F to 95 F Attention The Service LED flashes and the Fan LED flashes if th...

Page 22: ...ptions are described in the following sections QSFP ports Sixteen 40 GbE QSFP ports are located on the front panel These ports accept supported optical QSFP transceivers or direct attach cables DACs T...

Page 23: ...data pair D positive 8 BI DD Bi directional data pair D negative Console port The RS 232 mini USB serial console port is located on the front panel The following table describes the pinouts for the mi...

Page 24: ...You can also start the switch using files on the USB drive For more information about using the USB drive see the Release Notes for the switch Switch LEDs Two LED stacks provide system status and port...

Page 25: ...4 Not applicable Not applicable Not applicable Note 1 If service required is due to a power supply failure this LED flashes Otherwise it is steady green Note 2 If service required is due to fan failu...

Page 26: ...onmental specifications for the RackSwitch are listed in the following table Table 10 Environmental specifications Specification Measurement Temperature ambient operating 0 C to 40 C 32 to 104 F Tempe...

Page 27: ...ut current typical 2 35 A RMS 120 V 1 22 A RMS 230 V AC input current maximum 3 125 A RMS 120 V 1 630 A RMS 230 V Power supply rated output power 450 W each System power dissipation typical 330 W Syst...

Page 28: ...12 IBM System Networking RackSwitch G8316 Type 8036 and Type 1611 16E Installation Guide...

Page 29: ...ing table The identification labels contain the machine type model MTM number serial number and part number front rear panel and or bottom of the unit and the media access control MAC address rear of...

Page 30: ...__________________________________________ MAC addresses for other components _____________________________________________ _____________________________________________ ______________________________...

Page 31: ...switch meets the following requirements v Install the switch unit in a dry clean well ventilated area v Provide adequate space in the front and back of the switch unit to ensure proper air flow v Make...

Page 32: ...ached to this product to properly wired outlets v When possible use one hand only to connect or disconnect signal cables v Never turn on any equipment when there is evidence of fire water or structura...

Page 33: ...without setting it down If it is necessary to set down the device put it back into its static protective package Do not place the device on a switch cover or on a metal surface v Take additional care...

Page 34: ...nt switch copy the product information from the original switch onto the RID label that is shipped with replacement switch and affix the new label to the bottom of the new switch 2 Use the M4 screws t...

Page 35: ...age 43 Attention If this is a switch replacement make sure the VPD is updated to avoid losing the licensed electronic entitlement data of the RackSwitch For more information see Configuring Vital Prod...

Page 36: ...6 screws 8 4 M6 clip nuts 8 5 M4 screws 16 6 Switch front bracket 2 7 Switch rear bracket 2 8 Rear mounting bracket 2 DANGER Rack mounted devices are not to be used as shelves or work spaces L002 To i...

Page 37: ...itch unit into the rack Torque the screws to approximately 5 7 Nm 0 1 Nm 50 inch pounds 2 3 4 5 Use the M6 washers screws and clip nuts are used to attach the alignment plate Torque the screws to appr...

Page 38: ...stalling the RackSwitch in the standard equipment rack on page 17 v Installing the RackSwitch in the IBM iDataPlex rack on page 20 The IBM System Networking adjustable 19 4 post rail mount kit parts m...

Page 39: ...on from the original switch onto the RID label that is shipped with replacement switch and affix the new label to the bottom of the new switch 2 Use the M4 screws to attach the front mounting brackets...

Page 40: ...ting brackets 10 11 SEE STEP 5 5 Use the M6 washers screws and clip nuts to attach the filler plate to the rear mounting brackets Torque the screws to approximately 5 7 Nm 0 1 Nm 50 inch pounds 24 IBM...

Page 41: ...c entitlement data of the RackSwitch For more information see Configuring Vital Product Data after a switch replacement on page 40 Installing the 1U air duct option in a rack The RackSwitch supports a...

Page 42: ...1U Duct sleeve long 1 3 Mounting bracket right assembly 1U duct 1 4 Mounting bracket left assembly 1U duct 1 5 Foam carrier assembly includes half shears and foam carrier 2 7 Screw slotted M3 5 7 mm...

Page 43: ...secure the foam carrier assemblies snugly against the rear of the RackSwitch unit Torque the screws to approximately 1 1 Nm 10 inch pounds Note There are additional M3 5 screws in the air duct assemb...

Page 44: ...4 thumbscrews to secure the air duct unit to the air duct brackets For information about removing the air duct see Removing the 1U air duct option on page 39 Installing a QSFP transceiver The RackSwit...

Page 45: ...wing steps Note To avoid damage to the cable or the SFP transceiver do not connect the cable before you install the transceiver 1 Remove the safety cap and pull the locking lever into the down unlocke...

Page 46: ...30 IBM System Networking RackSwitch G8316 Type 8036 and Type 1611 16E Installation Guide...

Page 47: ...v Removing the 1U air duct option on page 39 v Removing and replacing the main RackSwitch chassis unit on page 39 Removing and replacing the RackSwitch chassis unit from a rack This section describes...

Page 48: ...h 5 6 Removing the RackSwitch from an iDataPlex rack To remove the RackSwitch from an iDataPlex rack complete the following steps 1 Disconnect all cables 2 Loosen and remove the M6 washers screws and...

Page 49: ...unt the switch unit into the rack 2 3 4 4 Slide the RackSwitch out of the rack 5 Loosen and remove the M4 screws that attach front and rear mounting brackets to each side of the switch unit 6 5 1 7 Ch...

Page 50: ...move M3 screws that secure the rear brackets to the front brackets 9 10 11 3 3 Loosen and remove M6 washers screws and clip nuts that attach the filler plate to the rear mounting brackets 4 2 6 8 4 Sl...

Page 51: ...onnect the front mounting brackets to the front and rear posts in the rack 6 2 4 6 Slide the RackSwitch out of the rack 7 Loosen and remove the M4 screws that attach the front mounting brackets to eac...

Page 52: ...wer supply module LEDs LED status Description OK Green DC output power is present Off DC output power is OK Service Amber Power supply or fan module failure Off Power supply and fan modules are operat...

Page 53: ...pply module into the power supply slot and gently push it into the slot until it latches Each power supply module has a mechanical guide key to prevent you from inserting the module incorrectly 2 Conn...

Page 54: ...he retainer screw 2 Grasp the extractor handle and gently pull the fan module from the slot Attention Replace the fan module within 5 minutes to avoid overheating the switch Replacing the fan module T...

Page 55: ...assistance on page 55 to help you gather all the required information that is necessary to return a component After you remove the component securely pack the component for shipping For instructions...

Page 56: ...them in the order in which they are listed v Replacing the AC power supply module on page 37 v Replacing the fan module on page 38 v Chapter 2 Installing the RackSwitch and options on page 13 Configur...

Page 57: ...rdware Revision 0 Hardware Part No BAC 000 a 00 Switch Serial No US7C45t78 Manufacturing date Software Version 6 6 0 FLASH image1 active configuration Temperature Mother Top 34 C Temperature Mother Bo...

Page 58: ...t IP Address if 127 Software Version 7 5 0 FLASH image2 active configuration Hardware Part Number 46C7193 Hardware Revision 05 Serial Number PROTO2C04E Manufacturing Date 43 08 PCBA Part Number BAC 00...

Page 59: ...Supply Steady green if both power cords are connected flashing green if only one power cord is connected v Service Off if the system is OK flashing if service is required Use the mini USB console cabl...

Page 60: ...ication Port 7 State UP Password At the Password prompt enter the switch password and press Enter The default password is admin Default configuration The switch software contains default factory loade...

Page 61: ...G8316 config interface ip 1 3 Configure an IP interface subnet mask and VLAN assignment Enable the interface RS G8316 config ip if ip address 10 10 10 2 example IP address RS G8316 config ip if ip net...

Page 62: ...ht have features that are not described in the documentation that comes with the switch and the documentation might be updated occasionally to include information about those features or technical upd...

Page 63: ...onfiguration If the switch port is set to auto negotiate make sure that the other device is set to auto negotiate Solution 2 Check the cables that connect the port to the other device Make sure that t...

Page 64: ...48 IBM System Networking RackSwitch G8316 Type 8036 and Type 1611 16E Installation Guide...

Page 65: ...G8316 front to rear 8036 AFX 8036 HC1 Not applicable 00D9801 Switch rack G8316 rear to front 8036 ARX 8036 HC2 Not applicable 00D9801 Power supplies 110 220 V front to rear airflow 8036 AFX 8036 HC1 4...

Page 66: ...Y3521 45D6369 Kit serial cable 8036 AFX 8036 ARX 8036 HC1 8036 HC2 90Y9462 94Y5444 Rail mounting kits 2 post rack 8036 AFX 8036 ARX 8036 HC1 8036 HC2 Not applicable 90Y3532 iDataPlex rack 8036 AFX 803...

Page 67: ...ion CSA For units intended to be operated at 115 volts Use a UL listed and CSA certified cord set consisting of a minimum of 18 AWG Type SVT or SJT three conductor cord a maximum of 15 feet in length...

Page 68: ...d 4 3 m 10A 100 250V C13 to C14 39Y7932 Rack power cord 1 8 m 10A 100 250V 2 C13PM IEC 320 C14 43V6034 Rack power cord 2 8 m 10A 230V C13 to CEE7 VII Europe 59Y8142 Line cord 2 8 m 10A 250V C13 BS 136...

Page 69: ...OEM PDU 200 240V 10A IEC320 C13 PT 22 39M5144 Line cord 2 8 m 9 ft to wall OEM PDU 200 240V 10A IEC320 C13 PT 23 39M5151 Line cord 2 8 m 9 ft to wall OEM PDU 200 240V 10A IEC320 C13 PT 24 39M5158 Lin...

Page 70: ...54 IBM System Networking RackSwitch G8316 Type 8036 and Type 1611 16E Installation Guide...

Page 71: ...a hardware service and support is available 24 hours a day 7 days a week In the U K these services are available Monday through Friday from 9 a m to 6 p m To open a support call complete the following...

Page 72: ...ial number http www ecurep ibm com app upload_hw v Secure upload http www ibm com de support ecurep send_http html secure v Secure upload with the system serial number https www ecurep ibm com app upl...

Page 73: ...SS FOR A PARTICULAR PURPOSE Some states do not allow disclaimer of express or implied warranties in certain transactions therefore this statement may not apply to you This information could include te...

Page 74: ...B stands for 1024 bytes MB stands for 1 048 576 bytes and GB stands for 1 073 741 824 bytes When referring to hard disk drive capacity or communications volume MB stands for 1 000 000 bytes and GB sta...

Page 75: ...tes and gases Contaminant Limits Particulate v The room air must be continuously filtered with 40 atmospheric dust spot efficiency MERV 9 according to ASHRAE Standard 52 21 v Air that enters a data ce...

Page 76: ...uipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation o...

Page 77: ...Department M372 IBM Allee 1 71139 Ehningen Germany Tele 0049 0 7032 15 2941 Email lugi de ibm com Germany Class A statement Deutschsprachiger EU Hinweis Hinweis f r Ger te der Klasse A EU Richtlinie...

Page 78: ...1900 Der verantwortliche Ansprechpartner des Herstellers in der EU ist IBM Deutschland GmbH Technical Regulations Department M372 IBM Allee 1 71139 Ehningen Germany Tele 0049 0 7032 15 2941 Email lug...

Page 79: ...ipment for business Type A Sellers and users need to pay attention to it This is for any areas other than home Russia Electromagnetic Interference EMI Class A statement People s Republic of China Clas...

Page 80: ...64 IBM System Networking RackSwitch G8316 Type 8036 and Type 1611 16E Installation Guide...

Page 81: ...ntal requirements 15 environmental specifications 10 F fan description 5 fan module installing 38 LED descriptions 38 removing 38 FCC Class A notice 60 G gaseous contamination 59 getting help 55 H hel...

Page 82: ...nts 7 S specifications environmental 10 power 10 standard rack installing the RackSwitch 17 23 mounting parts 17 switch before installing 13 environmental requirements 15 identification labels 13 inst...

Page 83: ......

Page 84: ...Part Number 00AY386 Printed in USA 1P P N 00AY386...