Automatic detection of hardware failures

 Provides alerts.

 Takes corrective action.

 Notifies IBM of problems to escalate problem determination.

Administrative capabilities, such as setting up users within profile groups, assigning security 

levels, and security governance. 
Bare metal deployment of hypervisors (VMware/ESXi, KVM) through centralized images.

IEEE 802.1Qbg support for x86 and Power Systems compute nodes

Remote restart for Power Systems provides the capability to activate a PowerVM partition on any 

appropriately configured running server in the unlikely event that the partition’s original server and 
any associated service partitions or management entities becomes unavailable.
FSM capacity utilization allows the system administrators to understand remaining FSM 

management capacity.

Network management integration

The IBM Flex System Manager management node has two types of  interfaces that can be configured. 
The Eth0 interface (two 1 Gb Ethernet management ports) and the IMM2 network interface are connected 
to the basic Layer 2 switch integrated into the FSM hardware. The integrated switch is connected to the 
Chassis Management Module (CMM) through the chassis internal management network. The CMM is 
connected to a top-of-rack switch that effectively extends the chassis management network outside of the 
chassis and provides a central connection point for all Enterprise Chassis hardware to be managed by the 
IBM Flex System Manager management software. These connections are referred to as the management 
network.

Summary of Contents for Flex System Manager

Page 1: ...ollowing figure Figure 1 IBM Flex System Manager management appliance Did you know IBM Flex System a new category of computing and the next generation of Smarter Computing offers intelligent workload...

Page 2: ...up wizards make deploying compute nodes quick and easy using the IBM Flex System Manager After it is deployed IBM Flex System Manager provides real time updates for compute node health summaries With...

Page 3: ...tware contains a set of components that are responsible for performing certain management functions These components must be activated using the available IBM Feature on Demand FoD software entitlemen...

Page 4: ...ed Chassis with 3 Year SW S S 00D7554 Fabric Provisioning feature upgrade IBM Flex System Manager Service Fabric Provisioning w 1 Yr S S 90Y4221 IBM Flex System Manager Service Fabric Provisioning w 3...

Page 5: ...isioning Fabric provisioning functionality is included in the advanced feature set It is also available as a separate Fabric Provisioning feature upgrade for the base feature set The Advanced Upgrade...

Page 6: ...ovided to VMControl Logical views of servers and network devices grouped by subnet and VLAN Network management advanced feature set or fabric provisioning feature Defines QoS settings for logical netw...

Page 7: ...matically without user intervention replace a failed compute node from a designated pool of spare compute nodes Preassigns MAC addresses WWN addresses and storage boot targets for the compute nodes Cr...

Page 8: ...gement entities becomes unavailable FSM capacity utilization allows the system administrators to understand remaining FSM management capacity Network management integration The IBM Flex System Manager...

Page 9: ...switch modules that are installed in I O bay 1 or bay 2 This setup is referred to as the data network You can configure a switch module in bay 1 or bay 2 to map Eth1 to one of its external Ethernet po...

Page 10: ...Managed systems without any IBM Flex System Manager software installed IBM Flex System Manager communicates with the managed system through the operating system Agentless out of band Managed systems w...

Page 11: ...Compute nodes running VMware and managed by vCenter Yes Yes No No Other managed resources supporting SSH or SNMP Yes Yes No No The following table summarizes the management tasks supported by the comp...

Page 12: ...o No Yes Deploy server system pools Yes Yes No No Yes Deploy storage system pools Yes Yes No No No Linux on IBM Power Systems compute nodes Supported only for virtual servers that are running IBM i v7...

Page 13: ...ated logical network provisioning ALNP Yes Yes Yes Yes No The following table shows supported storage systems and their management tasks Table 9 Supported storage systems and management tasks Storage...

Page 14: ...order and Integrated Management Module IMM and Unified Extensible Firmware Interface UEFI settings for one or more compute nodes before you deploy operating system or virtual images to them Installin...

Page 15: ...e chassis and multiple management nodes from a single application Authentication and security Secure all connections using encrypted protocols for example SSL and secure persistent credentials on your...

Page 16: ...C 50 95 degrees F server on 0 0 60 0 degrees C 32 140 degrees F server off Relative humidity 10 80 Maximum altitude 3 048 m 10 000 ft at 28 degrees C Decrease the maximum altitude by 1 000 ft for eve...

Page 17: ...com common ssi cgi bin ssialias infotype dd subtype ca htmlfid 897 ENUS212 088 US Announcement Letter 212 105 IBM Fabric Manager http ibm com common ssi cgi bin ssialias infotype dd subtype ca htmlfi...

Page 18: ...aterials for this IBM product and use of those Web sites is at your own risk IBM may use or distribute any of the information you supply in any way it believes appropriate without incurring any obliga...

Page 19: ...symbol or indicating US registered or common law trademarks owned by IBM at the time this information was published Such trademarks may also be registered or common law trademarks in other countries A...

Reviews: