Introduction
33
Managing the switch
2
In this syntax,
ntp1
is the IP address or DNS name of the first NTP server, which the switch
must be able to access.
Ntp2
is the name of the second NTP server and is optional. The entire
operand “<
ntp1;ntp2
>” is optional; by default, this value is LOCL, which uses the local clock of
the principal or primary switch as the clock server.
switch:admin>
tsclockserver
LOCL
switch:admin>
tsclockserver "132.163.135.131"
switch:admin> tsclockserver
132.163.135.131
The following example shows how to set up more than one NTP server using a DNS name:
switch:admin> tsclockserver "10.32.170.1;10.32.170.2;ntp.localdomain.net"
Updating Clock Server configuration...done.
Updated with the NTP servers
Changes to the clock server value on the principal or primary FCS switch are propagated to all
switches in the fabric.
Managing the switch
SNMP v3 authentication
Two user roles are supported:
•
snmpadmin—Provides read-write access
•
snmpuser—Provides read-only access
lists user login information. Each entry requires a separate password. The default
algorithm (MD5/SHA) is used to create the authentication keys.
1. AES = 128-bit encryption
For more information, refer to the snmpConfig commands supporting SNMPv3 configuration
parameters, as described in the
Fabric OS Command Reference Manual
.
TABLE 10
SNMP authentication and privacy protocols
User
Authentication password Authentication protocol
Privacy password
Privacy protocol
1
Access type
snmpadmin2
admin2
MD5
admin2
AES
Get/Set
snmpadmin3
admin3
SHA
admin3
AES
Get/Set
snmpuser1
user1
SHA
user1
AES
Get
snmpuser2
user2
SHA
user2
AES
Get
snmpuser3
user3
SHA
user3
AES
Get
Summary of Contents for FC5022
Page 1: ...IBM Flex System FC5022 16Gb SAN Scalable Switch User s Guide ...
Page 2: ......
Page 3: ...IBM Flex System FC5022 16Gb SAN Scalable Switch User s Guide ...
Page 8: ...vi IBM Flex System FC5022 16Gb SAN Scalable Switch User s Guide ...
Page 17: ...Introduction 3 Notices and statements 1 Notices and statements Notices for Network Device ...
Page 66: ...52 IBM Flex System FC5022 16Gb SAN Scalable Switch User s Guide Electronic emission notices B ...
Page 69: ......
Page 70: ...Part Number 88Y7924 Printed in USA IP P N 88Y7924 88Y7924 ...