Attention:
It
is
recommended
that
you
stop
all
I/O
processes
before
hot-adding
an
EXN1000
to
an
existing
loop.
Perform
a
hot-add
only
during
off-peak
times.
To
hot-add
an
EXN1000
expansion
unit
to
an
existing
loop,
complete
the
following
steps:
1.
Put
on
the
antistatic
ESD
strap
and
grounding
leash.
2.
Verify
that
you
received
the
disk
shelf
ID
labels.
3.
Install
the
new
EXN1000
expansion
unit
in
the
rack,
cable
and
ground
the
EXN1000,
and
connect
the
power
cables
to
the
EXN1000,
as
described
in
the
Installation
and
Setup
Instructions
you
received
with
your
N
series
product.
CAUTION:
Do
not
turn
on
the
power
to
the
EXN1000
expansion
unit
yet.
After
you
have
completed
the
installation
steps
described
in
the
Installation
and
Setup
Instructions
,
continue
with
Step
4.
4.
Verify
that
all
the
cables
are
securely
fastened.
CAUTION:
Poorly
secured
cables
cause
the
N
series
storage
system
to
panic
over
an
open
loop.
5.
If
you
have
not
done
so,
give
the
EXN1000
expansion
unit
a
unique
disk
shelf
ID.
It
is
recommended
that
you
choose
a
number
which
is
one
higher
than
the
previous
shelf
(or
ID
1
if
this
is
the
first
EXN1000
in
the
loop).
a.
Press
the
small
buttons
on
the
switch
on
the
rear
of
the
EXN1000
expansion
unit,
using
the
+
button
to
raise
the
number
and
the
-
button
to
lower
the
number
to
a
valid
ID
from
1
through
7.
Refer
to
for
an
illustration.
Note:
Only
use
disk
shelf
ID
7
if
it
is
the
last
ID
available.
If
you
change
a
disk
shelf
ID,
you
must
power-cycle
the
EXN1000
expansion
unit
for
the
new
ID
to
take
effect.
The
disk
shelf
ID
display
on
the
front
of
the
EXN1000
expansion
unit
blinks
until
you
power-cycle
the
EXN1000
expansion
unit.
b.
Verify
that
the
disk
shelf
ID
is
not
being
used
in
the
loop
by
entering
the
following
command
at
the
console:
fcstat
device_map
adaptername
c.
Select
the
correct
matching
shelf
ID
label,
reference
and
attach
it
to
the
right
flange
of
the
new
EXN1000
expansion
unit.
CAUTION:
An
invalid
disk
shelf
ID
causes
the
N
series
storage
system
to
panic.
6.
Turn
on
the
power
to
the
EXN1000
expansion
unit.
You
must
wait
30
seconds
for
the
shelf
electronics
to
finish
initializing.
16
Summary of Contents for EXN1000
Page 1: ...IBM System Storage EXN1000 Storage Expansion Unit Hardware and Service Guide GC26 7802 02...
Page 2: ......
Page 3: ...IBM System Storage EXN1000 Storage Expansion Unit Hardware and Service Guide GC26 7802 02...
Page 20: ...xviii...
Page 22: ...xx...
Page 24: ...xxii...
Page 48: ...18...
Page 58: ...28...
Page 70: ...40...
Page 74: ...44...
Page 80: ...50...
Page 93: ......
Page 94: ...Printed in USA GC26 7802 02...