v
WOL
- An indication of whether the Wake on LAN feature is
currently enabled for the blade server. The Wake on LAN feature
is enabled by default in blade server BIOS code and cannot be
disabled. The BladeCenter management module provides a
single point of control for the Wake on LAN feature, allowing the
settings to be controlled for either the entire BladeCenter unit or
a single blade server. Wake on LAN settings made in the
management module override the settings in the blade server
BIOS code.
v
Local Control
- an indication of whether the following options
are enabled:
– Local power control
– Local keyboard, video, and mouse switching
– Local CD-ROM drive, diskette drive, and USB port switching
Switch modules:
v
Bay
- The number of the bay the switch module occupies.
v
Status
- Icon that indicates good, warning, or bad for the
particular switch module.
v
Type
- The network interface (Ethernet or Fibre Channel) the
switch module uses.
v
MAC Address
- The medium access control (MAC) address of
the switch module.
v
IP Address
- The IP address of the switch module.
v
Power
- The power state (on or off) of the switch module.
v
Details
- Text information about the status of the switch module.
Management module:
v
Bay
- The number of the bay that the management module
occupies.
v
Status
- An icon that indicates good, warning, or critical for the
particular management module. Click the icon for more detailed
status information.
v
IP Address
- The IP address of the remote connection (external
Ethernet port) on the management module.
Power Modules:
v
Bay
- The number of the bay that the power module occupies.
v
Status
- An icon that indicates good, warning, or critical for the
particular power module.
v
Details
- Text information about the status of the power module.
Blowers:
v
Bay
- The number of the bay that the blower module occupies.
v
Status
- An icon that indicates good, warning, or critical for the
particular blower module.
v
Speed
- The current speed of the blower module, as a
percentage of the maximum revolutions per minute (RPMs). The
blower speed varies with the thermal load. An entry of
Offline
indicates that the blower is not functioning.
46
BladeCenter Type 8677: Installation and User’s Guide
Summary of Contents for eServer BladeCenter 8677
Page 3: ...BladeCenter Type 8677 Installation and User s Guide ERserver...
Page 8: ...vi BladeCenter Type 8677 Installation and User s Guide...
Page 28: ...12 BladeCenter Type 8677 Installation and User s Guide...
Page 54: ...38 BladeCenter Type 8677 Installation and User s Guide...
Page 96: ...80 BladeCenter Type 8677 Installation and User s Guide...
Page 106: ......
Page 107: ......
Page 108: ...IBM Part Number 59P6546 Printed in the United States of America 59P6546...