Figure 9. Displaying drive carrier assembly
Fully assembled drive carrier assembly with one of the following options exactly matches the other drives
that are installed in the same enclosure:
• Part number - 01LL727 3.84 TB 2.5" PCIe Gen4 NVMe Flash drive
• Part number - 01LL728 7.68 TB 2.5" PCIe Gen4 NVMe Flash drive
• Part number - 01LL729 15.36 TB 2.5" PCIe Gen4 NVMe Flash drive
• Part number - 01LL831 38.4 TB FCM 2.1 PCIe Gen3 NVMe Flash drive
Figure 10. Displaying NVMe drive replacement part
Refer to the following steps to remove and replace a faulty NVMe drive:
1. Confirm the failed drive location from the fault drive LED.
You can identify the failed drive by the amber fault LED on the drive carrier. If the fault LED is lit on a
drive, it is safe to replace the drive.
Alternatively, locate unhealthy drives in the management GUI, either from the Storage> Physical
Disks page as shown in Figure 11 on page 7, or from the list of events that are available under the
Monitoring > Events page.
6 IBM Elastic Storage System 3200: Service Guide
Summary of Contents for Elastic Storage System 3200
Page 1: ...IBM Elastic Storage System 3200 6 1 3 Service Guide IBM SC27 9862 00 ...
Page 4: ...iv ...
Page 8: ...viii ...
Page 12: ...xii IBM Elastic Storage System 3200 Service Guide ...
Page 42: ...30 IBM Elastic Storage System 3200 Service Guide ...
Page 46: ...34 IBM Elastic Storage System 3200 Service Guide ...
Page 50: ...38 IBM Elastic Storage System 3200 Service Guide ...
Page 58: ...46 IBM Elastic Storage System 3200 Service Guide ...
Page 60: ...48 IBM Elastic Storage System 3200 Service Guide ...
Page 62: ...50 IBM Elastic Storage System 3200 Service Guide ...
Page 63: ......
Page 64: ...IBM Product Number 5765 DME 5765 DAE SC27 9862 00 ...