Power Control
Each fan-and-power-supply assembly in the 2104 has a DC On/Standby switch.
The power to the 2104 is also controlled by the Power Control switch on the switch
card.
Power Sequencing
The power sequencing of the disk drive modules in a 2104 is controlled by the settings
of the Drive Auto-Start and Select Enclosure Services switches on the switch card.
These are:
Drive Auto-Start switch
Select Enclosure
Services switch
Power Sequence
OFF
OFF
Normal Start
ON
OFF
Command Start
OFF
ON
Delayed Start
ON
ON
Reserved
Auto Restart
2104s automatically restart when input power is restored within specification after a
power failure. The disk drive module motors start under the control of the using system.