EY:
At
least
one
Volterra
master
supply
reported
over
voltage
after
power
up
of
stage
3
EZ:
At
least
one
Volterra
master
supply
reported
over
voltage
after
power
up
of
stage
4
F1:
At
least
one
Volterra
master
supply
reported
over
voltage
during
continuous
monitoring
F3:
At
least
one
Volterra
slave
supply
reported
voltage
fault
after
power
up
of
stage
0
F4:
At
least
one
Volterra
slave
supply
reported
voltage
fault
after
power
up
of
stage
1
F5:
At
least
one
Volterra
slave
supply
reported
voltage
fault
after
power
up
of
stage
2
F6:
At
least
one
Volterra
slave
supply
reported
voltage
fault
after
power
up
of
stage
3
F7:
At
least
one
Volterra
slave
supply
reported
voltage
fault
after
power
up
of
stage
4
F8:
At
least
one
Volterra
slave
supply
reported
voltage
fault
during
continuous
monitoring
FA:
Monitored
voltage
1.800
V
1.8V_SB_RAMBUS
failed
maverick
limits
FB:
Monitored
voltage
1.200
V
1.2V_VDDIO
failed
maverick
limits
FC:
Monitored
voltage
1.120
V
BE0_VDDC
failed
maverick
limits
FD:
Monitored
voltage
1.120
V
BE1_VDDC
failed
maverick
limits
FE:
Monitored
voltage
2.500
V
failed
maverick
limits
FF:
Monitored
voltage
12.00
V
+12V_PCIE
failed
maverick
limits
FG:
Monitored
voltage
3.300
V
3.3V_SB_VDD
failed
maverick
limits
FH:
Monitored
voltage
1.200
V
SB_VDDIO
failed
maverick
limits
FI:
Monitored
voltage
1.800
V
1.8V_SB
failed
maverick
limits
FJ:
Monitored
voltage
1.500
V
SB_VDDA_VTERM
failed
maverick
limits
FK:
Monitored
voltage
1.500
V
1.5V_VDDA_BE0
failed
maverick
limits
FL:
Monitored
voltage
1.500
V
1.5V_VDDA_BE1
failed
maverick
limits
FM:
Monitored
voltage
5.000
V
+5V_HDD
failed
maverick
limits
FN:
Monitored
voltage
PC12V1_GATE1
failed
maverick
limits
FO:
Monitored
voltage
PC12V1_GATE2
failed
maverick
limits
FP:
Monitored
voltage
PC12V1_GATE2
failed
maverick
limits
G1:
The
blade
has
been
inserted
into
the
Blade
Center
in
a
forbidden
slot.
G2:
BE0
indicates
a
checkstop
condition.
G3:
BE1
indicates
a
checkstop
condition.
G4:
The
system
info
could
not
be
read
from
VPD
G5:
The
BE
core
voltages
can
not
be
read
from
VPD
during
device
initialization
because
VPD
is
constantly
busy
G6:
The
revision
ID
of
the
ICS9214
clock
multiplier
chip
is
not
supported
GA:
Junction
temperature
of
Volterra
master
device
PS1
exceeded
maximum
limit
GB:
Junction
temperature
of
Volterra
master
device
PS2
exceeded
maximum
limit
GC:
Junction
temperature
of
Volterra
master
device
PS3
exceeded
maximum
limit
GD:
Junction
temperature
of
Volterra
master
device
PS4
exceeded
maximum
limit
Warning
log
IDs
W1:
NVRAM
boot
bank
is
switched
to
permanent
side
due
to
watchdog
trigger
W2:
OS
surveillance
watchdog
triggered
system
reset
W3:
No
response
from
the
ADT7467
remote
thermal
monitor
and
fan
controller.
Retry
is
done.
W4:
It
was
tried
to
access
the
VPD
while
it
was
busy
W5:
No
valid
BE
core
voltage
stored
in
VPD.
Default
values
are
used.
W6:
Tried
to
set
Volterra
VID
but
set
process
is
still
busy
W7:
One
retry
was
required
to
set
the
Volterra
VID
W8:
One
retry
was
required
to
read
the
Volterra
VID
W9:
Three
consecutive
readings
form
VID
register
do
not
match
WA:
Monitored
voltage
1.800
V
1.8V_SB_RAMBUS
failed
spec
limits
WB:
Monitored
voltage
1.200
V
1.2V_VDDIO
failed
spec
limits
WC:
Monitored
voltage
1.120
V
BE0_VDDC
failed
spec
limits
WD:
Monitored
voltage
1.120
V
BE1_VDDC
failed
spec
limits
WE:
Monitored
voltage
2.500
V
failed
spec
limits
WF:
Monitored
voltage
12.00
V
+12V_PCIE
failed
spec
limits
WG:
Monitored
voltage
3.300
V
3.3V_SB_VDD
failed
spec
limits
WH:
Monitored
voltage
1.200
V
SB_VDDIO
failed
spec
limits
WI:
Monitored
voltage
1.800
V
1.8V_SB
failed
spec
limits
WJ:
Monitored
voltage
1.500
V
SB_VDDA_VTERM
failed
spec
limits
WK:
Monitored
voltage
1.500
V
1.5V_VDDA_BE0
failed
spec
limits
WL:
Monitored
voltage
1.500
V
1.5V_VDDA_BE1
failed
spec
limits
WM:
Monitored
voltage
5.000
V
+5V_HDD
failed
spec
limits
WN:
Monitored
voltage
PC12V1_GATE1
failed
spec
limits
WO:
Monitored
voltage
P12V2_GATE2
failed
spec
limits
WP:
Monitored
voltage
P12V3_GATE2
failed
spec
limits
WX:
It
has
been
tried
to
change
power
permission
on
a
powered
up
system.
This
is
illegal.
Request
is
ignored.
26
BladeCenter
QS20
Type
0200:
Problem
Determination
and
Service
Guide
Summary of Contents for BladeCenter QS20
Page 1: ...BladeCenter QS20 Type 0200 Problem Determination and Service Guide SC33 8297 00...
Page 2: ......
Page 3: ...BladeCenter QS20 Type 0200 Problem Determination and Service Guide SC33 8297 00...
Page 8: ...vi BladeCenter QS20 Type 0200 Problem Determination and Service Guide...
Page 26: ...8 BladeCenter QS20 Type 0200 Problem Determination and Service Guide...
Page 49: ...v Operating system control file setup Chapter 2 Diagnostics and troubleshooting 31...
Page 50: ...32 BladeCenter QS20 Type 0200 Problem Determination and Service Guide...
Page 56: ...38 BladeCenter QS20 Type 0200 Problem Determination and Service Guide...
Page 80: ...62 BladeCenter QS20 Type 0200 Problem Determination and Service Guide...
Page 94: ...76 BladeCenter QS20 Type 0200 Problem Determination and Service Guide...
Page 98: ...80 BladeCenter QS20 Type 0200 Problem Determination and Service Guide...
Page 99: ......
Page 100: ...Part Number 42C4969 Printed in USA SC33 8297 00 1P P N 42C4969...