CP:
BE1
RX4
parallel
and
slice
cal
status
not
correct
during
SB0
bit
training
CQ:
SB0
RX0
parallel
and
slice
cal
status
not
correct
during
SB0
bit
training
CR:
SB1
RX0
parallel
and
slice
cal
status
not
correct
during
SB0
bit
training
CS:
BE0
BX0
status
A
not
correct
during
RRAC
SB
bit
training
CT:
BE1
BX0
status
A
not
correct
during
RRAC
SB
bit
training
CU:
BE0
BX1
status
A
not
correct
during
RRAC
SB
bit
training
CV:
BE1
BX1
status
A
not
correct
during
RRAC
SB
bit
training
CW:
BE0
BX0
status
B
not
correct
during
RRAC
SB
bit
training
CX:
BE1
BX0
status
B
not
correct
during
RRAC
SB
bit
training
CY:
BE0
BX1
status
B
not
correct
during
RRAC
SB
bit
training
CZ:
BE1
BX1
status
B
not
correct
during
RRAC
SB
bit
training
C1:
BE0
TX6
PLL
status
not
correct
during
RRAC
SB
bit
training
C2:
BE1
TX6
PLL
status
not
correct
during
RRAC
SB
bit
training
C3:
BE0
RX4
PLL
status
not
correct
during
RRAC
SB
bit
training
C4:
BE1
RX4
PLL
status
not
correct
during
RRAC
SB
bit
training
C5:
Failed
to
set
BE0
Volterra
VID.
Possibly
core
voltage
out
of
allowed
limit
C6:
Failed
to
set
BE1
Volterra
VID.
Possibly
core
voltage
out
of
allowed
limit
C7:
BE0
Poll
6
did
not
return
expected
value
C8:
BE1
Poll
6
did
not
return
expected
value
C9:
BE0
RX_G1_RX_STATUS
not
correct
during
RRAC
BE
to
BE
cal
C0:
BE1
RX_G1_RX_STATUS
not
correct
during
RRAC
BE
to
BE
cal
D0:
No
response
from
clock
device
XCG0
(BE
PLL)
D1:
No
response
from
clock
device
XCG1
(RC)
D2:
No
response
from
clock
device
XCG2
(Y)
DA:
No
response
from
an
unknown
clock
device
DB:
No
response
from
at
least
one
of
the
Volterra
power
supply
devices
DC:
No
response
from
the
ADT7467
remote
thermal
monitor
and
fan
controller
DD:
There
are
not
enough
timer
available
to
schedule
the
H8
program
DE:
H8
program
selftest
failed
with
application
error
DF:
H8
program
selftest
failed
with
ROM
error
DG:
H8
program
selftest
failed
with
RAM
error
DH:
H8
program
selftest
failed
with
external
reset
error.
E.g.
H8
watchdog
triggered
reboot.
DI:
No
response
from
the
VPD
memory
chip
DJ:
The
VID
that
is
set
in
the
volterra
master
device
does
not
match
to
the
target
VID
DK:
No
response
from
PS1
Volterra
master
device
during
VID
read/write
DL:
No
response
from
PS2
Volterra
master
device
during
VID
read/write
DM:
No
response
from
PS3
Volterra
master
device
during
VID
read/write
DN:
No
response
from
PS4
Volterra
master
device
during
VID
read/write
DO:
No
response
from
PS1
Volterra
master
device
during
junction
temperature
read
DP:
No
response
from
PS2
Volterra
master
device
during
junction
temperature
read
DQ:
No
response
from
PS3
Volterra
master
device
during
junction
temperature
read
DR:
No
response
from
PS4
Volterra
master
device
during
junction
temperature
read
E1:
Boot
from
NVRAM
permanent
side
failed.
Both
sides
are
broken.
EA:
12
V
controller
reported
over
current
after
power
up
of
stage
0
EB:
12
V
controller
reported
over
current
after
power
up
of
stage
1
EC:
12
V
controller
reported
over
current
after
power
up
of
stage
2
ED:
12
V
controller
reported
over
current
after
power
up
of
stage
3
EE:
12
V
controller
reported
over
current
after
power
up
of
stage
4
EF:
12
V
controller
reported
over
current
during
continuous
monitoring
EG:
Power
stage
0
did
not
come
up
within
specified
time
range
EH:
Power
stage
1
did
not
come
up
within
specified
time
range
EI:
Power
stage
2
did
not
come
up
within
specified
time
range
EJ:
Power
stage
3
did
not
come
up
within
specified
time
range
EK:
Power
stage
4
did
not
come
up
within
specified
time
range
EL:
Power
stage
0
failed
during
monitoring
EM:
Power
stage
1
failed
during
monitoring
EN:
Power
stage
2
failed
during
monitoring
EO:
Power
stage
3
failed
during
monitoring
EP:
Power
stage
4
failed
during
monitoring
EQ:
Stage
0
can
not
be
powered
down
ER:
Stage
1
can
not
be
powered
down
ES:
Stage
2
can
not
be
powered
down
ET:
Stage
3
can
not
be
powered
down
EU:
Stage
4
can
not
be
powered
down
EV:
At
least
one
Volterra
master
supply
reported
over
voltage
after
power
up
of
stage
0
EW:
At
least
one
Volterra
master
supply
reported
over
voltage
after
power
up
of
stage
1
EX:
At
least
one
Volterra
master
supply
reported
over
voltage
after
power
up
of
stage
2
Chapter
2.
Diagnostics
and
troubleshooting
25
Summary of Contents for BladeCenter QS20
Page 1: ...BladeCenter QS20 Type 0200 Problem Determination and Service Guide SC33 8297 00...
Page 2: ......
Page 3: ...BladeCenter QS20 Type 0200 Problem Determination and Service Guide SC33 8297 00...
Page 8: ...vi BladeCenter QS20 Type 0200 Problem Determination and Service Guide...
Page 26: ...8 BladeCenter QS20 Type 0200 Problem Determination and Service Guide...
Page 49: ...v Operating system control file setup Chapter 2 Diagnostics and troubleshooting 31...
Page 50: ...32 BladeCenter QS20 Type 0200 Problem Determination and Service Guide...
Page 56: ...38 BladeCenter QS20 Type 0200 Problem Determination and Service Guide...
Page 80: ...62 BladeCenter QS20 Type 0200 Problem Determination and Service Guide...
Page 94: ...76 BladeCenter QS20 Type 0200 Problem Determination and Service Guide...
Page 98: ...80 BladeCenter QS20 Type 0200 Problem Determination and Service Guide...
Page 99: ......
Page 100: ...Part Number 42C4969 Printed in USA SC33 8297 00 1P P N 42C4969...