Table
4.
Voltages
(continued)
Source
Value
Critical
Base
Vcc
1.2
V
+1.19
(+1.13
,
+1.26)
Base
Vcc
1.3
V
+1.31
(+1.22
,
+1.35)
Base
Vcc
1.5
V
+1.50
(+1.42
,
+1.56)
Base
Vcc
1.8
V
+1.77
(+1.70
,
+1.88)
Base
Vcc
12
V
+12.05
(+9.94
,
+13.92)
Base
Vcc
2.5
V
+2.52
(+2.37
,
+2.62)
Base
Vcc
3.3
V
+3.32
(+3.13
,
+3.46)
Base
Vcc
PX1
1.8
+1.76
(+1.70
,
+1.88)
Base
Vcc
PX2
1.8
+1.77
(+1.70
,
+1.88)
Base
Vtt
PAX
V
+1.66
(+1.48
,
+1.81)
Base
Vtt
QDR
V
+0.74
(+0.67
,
+0.81)
HSDC
1.0
V
Dig
+0.99
(+0.94
,
+1.05)
HSDC
1.8
V
Dig
+1.79
(+1.70
,
+1.88)
HSDC
12
V
In
+12.21
(+10.08
,
+14.10)
HSDC
2.5
V
Dig
+2.50
(+2.37
,
+2.62)
HSDC
5
V
Dig
+4.96
(+4.49
,
+5.49)
HSDC
N
1.5
V
+1.48
(+1.42
,
+1.56)
HSDC
N
3.3
V
+3.29
(+3.13
,
+3.46)
HSDC
N
MGT
1.0
+0.99
(+0.94
,
+1.05)
HSDC
N
PLL
1.2
+1.19
(+1.13
,
+1.26)
HSDC
N
Vtt
1.2
+1.19
(+1.13
,
+1.26)
HSDC
S
1.5
V
+1.49
(+1.42
,
+1.56)
HSDC
S
3.3
V
+3.27
(+3.13
,
+3.46)
HSDC
S
MGT
1.0
+0.98
(+0.94
,
+1.05)
HSDC
S
PLL
1.2
+1.19
(+1.13
,
+1.26)
Intermittent
problems
v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
to
determine
which
components
are
CRUs
and
which
components
are
FRUs.
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Symptom
Action
A
problem
occurs
only
occasionally
and
is
difficult
to
diagnose.
1.
Make
sure
that:
v
When
the
DPI
blade
is
turned
on,
air
is
flowing
from
the
rear
of
the
BladeCenter
unit
at
the
blower
grille.
If
there
is
no
airflow,
the
blower
is
not
working.
This
causes
the
DPI
blade
to
overheat
and
shut
down.
v
The
SAS
hard
disk
drives
are
configured
correctly.
2.
Check
the
Alarms
log
(see
3.
See
Chapter
5.
Diagnostics
53