Module LEDs
Use the following table to find solutions to problems that are identified by LEDs on
the modules installed in BladeCenter HT unit.
Note:
To find descriptions and actions for LEDs on I/O modules or blade servers,
see the documentation that comes with the device.
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 3, “Parts listing,” on page 23 to determine which components are CRUs and which
components are FRUs.
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
LED status
Description
Action
Management module:
Error LED lit
(Amber)
A critical error has occurred in
the management module.
1. Reseat the management module and
management-module interposer.
2. Reset and reconfigure the management
module. See the
BladeCenter Advanced
Management Module Installation Guide
for
more information.
3. Replace the management module.
Power module:
Input power LED not lit
(Green)
There is no power being
supplied to the power module
or the power module has failed.
Make sure that:
1. All power cords are plugged into compatible
power sources and that the power sources are
working.
2. The shuttle release handles are in the closed
position and the captive thumbscrews are
tightened.
Replace the power module with a power module
that is known to work. If the problem remains, go
to “Solving undetermined problems” on page 118.
Power module:
Output power LED not lit
(Green)
There is no power being
supplied to the power module
or the power module has failed.
Make sure that:
1. All power cords are plugged into compatible
power sources and that the power sources are
working.
2. The shuttle release handles are in the closed
position and the captive thumbscrews are
tightened.
Replace the power module with a power module
that is known to work. If the problem remains, go
to “Solving undetermined problems” on page 118.
Power module:
Fan error LED lit
(Amber)
The fan pack has failed.
Replace the fan pack.
Chapter 5. Diagnostics
115
Summary of Contents for BladeCenter HT 8740
Page 1: ...BladeCenter HT Type 8740 and 8750 Problem Determination and Service Guide ...
Page 2: ......
Page 3: ...BladeCenter HT Type 8740 and 8750 Problem Determination and Service Guide ...
Page 8: ...vi BladeCenter HT Type 8740 and 8750 Problem Determination and Service Guide ...
Page 48: ...30 BladeCenter HT Type 8740 and 8750 Problem Determination and Service Guide ...
Page 118: ...100 BladeCenter HT Type 8740 and 8750 Problem Determination and Service Guide ...
Page 142: ...124 BladeCenter HT Type 8740 and 8750 Problem Determination and Service Guide ...
Page 150: ...132 BladeCenter HT Type 8740 and 8750 Problem Determination and Service Guide ...
Page 156: ...138 BladeCenter HT Type 8740 and 8750 Problem Determination and Service Guide ...
Page 157: ......
Page 158: ... Part Number 00V9904 Printed in USA 1P P N 00V9904 ...