Error
code
Description
Action
166-411-001
System
Management:
Failed
(BMC
indicates
failure
in
I2C
bus
test)
Shutdown
and
remove
the
blade
server
from
the
BladeCenter
unit,
wait
30
seconds;
then,
reinstall
the
blade
server
in
the
BladeCenter
unit
and
restart
it.
If
problem
persists,
perform
the
following
tasks
in
the
order
shown,
restarting
the
blade
server
each
time:
1.
Remove
the
blade
server
from
the
BladeCenter
unit;
then,
remove
the
card
from
the
I/O
expansion
card
slot
B
in
the
Blade
Storage
Expansion
Unit
3.
Reinstall
the
blade
server
in
the
BladeCenter
unit
and
restart
it.
2.
Update
the
BMC
firmware.
3.
(Trained
service
technician
only)
Replace
the
system
board
assembly.
166-406-001
BMC
indicates
failure
in
I2C
bus
test.
1.
Remove
the
blade
server
from
the
BladeCenter
unit,
wait
30
seconds,
reseat
it
in
the
BladeCenter
unit,
and
run
the
test
again.
2.
Update
the
BMC
firmware
(see
“Firmware
updates”
on
page
11).
3.
(Trained
service
technician
only)
Replace
the
system
board
assembly.
166-407-001
System
Management:
Failed.
BMC
indicates
failure
in
I2C
bus
test.
1.
Remove
the
blade
server
from
the
BladeCenter
unit,
wait
30
seconds,
reseat
it
in
the
BladeCenter
unit,
and
run
the
test
again.
2.
Update
the
BMC
firmware
(see
“Firmware
updates”
on
page
11).
3.
(Trained
service
technician
only)
Replace
the
system
board
assembly.
166-nnn-001
System
Management:
Failed.
BMC
indicates
failure
in
self
test.
Note:
v
nnn
=
300
to
320
v
nnn
=
400
to
420,
excluding
406
and
407
1.
Remove
the
blade
server
from
the
BladeCenter
unit,
wait
30
seconds,
reseat
it
in
the
BladeCenter
unit,
and
run
the
test
again.
2.
Update
the
BMC
firmware
(see
“Firmware
updates”
on
page
11).
3.
(Trained
service
technician
only)
Replace
the
system
board
assembly.
180-xxx-000
Diagnostics
LED
failure.
Run
the
LED
test
in
the
diagnostics
program.
180-xxx-001
Failed
front
LED
panel
test.
1.
Reseat
the
control-panel
connector.
2.
Replace
the
bezel
assembly.
3.
(Trained
service
technician
only)
Replace
the
system
board
assembly.
180-xxx-002
Failed
diagnostics
LED
panel
test.
(Trained
service
technician
only)
Replace
the
system
board
assembly.
180-xxx-003
Failed
system
board
LED
test.
(Trained
service
technician
only)
Replace
the
system
board
assembly.
104
BladeCenter
HS21
Types
1885
and
8853:
Problem
Determination
and
Service
Guide
Summary of Contents for 8853L6U
Page 1: ...BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Page 8: ...vi BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Page 16: ...xiv BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Page 30: ...14 BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Page 145: ......
Page 146: ...Part Number 49Y0053 Printed in USA 1P P N 49Y0053...