Features
and
specifications
for
the
HS20
Type
8843
for
a
NEBS/ETSI
environments
Table
4
provides
a
summary
of
the
features
and
specifications
of
the
BladeCenter
HS20
Type
8843
blade
server
operating
in
a
NEBS/ETSI
environment.
Note:
Power,
cooling,
removable
media
drives,
external
ports,
and
advanced
system
management
are
provided
by
the
BladeCenter
T
Type
8720
unit.
Table
4.
8843
Features
and
specifications
Microprocessor:
Supports
up
to
2
microprocessors
v
Intel
Xeon
DP
processor
v
512
KB
ECC
L2
cache
v
533
MHz
front-side
bus
(FSB)
Memory:
v
Four
double
data
rate
(DDR)
PC3200
sockets
v
Minimum:
1
GB
v
Maximum:
8
GB
v
Type:
2-way
interleaved,
DDR,
PC2100,
ECC
SDRAM
registered
x4
(Chipkill)
dual
inline
memory
modules
(DIMMs)
only
Notes:
1.
PC2100
DIMMs
are
backward-compatible
and
can
function
in
the
PC1600
sockets
2.
Chipkill
is
available
for
DIMMs
with
512
MB
or
greater
v
Supports
512
MB,
1
GB,
and
2
GB
DIMMs
Drives:
v
Support
for
up
to
two
internal
IDE
2.5-inch
flash
drives
(NEBS
application
requires
flash-based
IDE
drives)
v
Support
for
up
to
two
Ultra320
SCSI
hot-swap
hard
disk
drives
available
in
the
optional
SCSI
storage
expansion
unit
Size:
v
Height:
24.5
cm
(9.7
inches)
v
Depth:
44.6
cm
(17.6
inches)
v
Width:
2.9
cm
(1.14
inches)
v
Maximum
weight:
5.4
kg
(12
lb)
Integrated
functions:
v
Two
Gigabit
Ethernet
controllers
v
ATI
Rage
XL
video
controller
v
Light
path
diagnostics
v
Local
service
processor
v
IDE
drive
controller
v
RS-485
interface
for
communication
with
the
management
module
v
USB
buses
for
communication
with
keyboard,
mouse,
CD-ROM
drive,
and
external
diskette
drive.
Predictive
Failure
Analysis
(PFA)
alerts:
v
Microprocessor
v
Memory
Electrical
input:
v
Input
voltage:
12
V
dc
Environment
(NEBS):
v
Air
temperature:
–
Blade
server
on:
5°
to
40°
C
(41°
to
104°
F).
Altitude:
-60
to
1800
m
(-197
to
6000
ft
)
–
Blade
server
on
(short
term):
-5°
to
55°
C
(23°
to
131°
F).
Altitude:
-60
to
1800
m
(-197
to
6000
ft)
–
Blade
server
on:
5°
to
30°
C
(41°
to
86°
F).
Altitude:
1800
to
4000
m
(6000
to
13000
ft)
–
Blade
server
on
(short
term):
-5°
to
45°C
(23°
to
113°
F).
Altitude:
1800
to
4000
m
(6000
to
13000
ft)
–
Blade
server
off:
-40°
to
70°
C
(-40°
to
158°
F)
v
Humidity:
–
Blade
server
on:
5%
to
80%
–
Blade
server
on
(short
term):
5%
to
90%,
but
not
to
exceed
0.024
kg
water/kg
of
dry
air
–
Blade
server
off:
uncontrolled
Note:
″
Short
term
″
refers
to
a
period
of
not
more
than
96
consecutive
hours
and
a
total
of
not
more
than
15
days
in
1
year.
(This
refers
to
a
total
of
360
hours
in
any
given
year,
but
no
more
than
15
occurrences
during
that
1-year
period.)
Note:
The
operating
system
in
the
blade
server
must
provide
USB
support
for
the
blade
server
to
recognize
and
use
the
keyboard,
mouse,
CD-ROM,
and
an
external
diskette
drive.
The
BladeCenter
T
unit
uses
USB
for
communications
with
these
devices.
20
BladeCenter
T
Types
8720
and
8730:
Planning
and
Installation
Guide
Summary of Contents for 87302RU
Page 1: ...BladeCenter T Types 8720 and 8730 Planning and Installation Guide GA27 4339 02 ...
Page 2: ......
Page 3: ...BladeCenter T Types 8720 and 8730 Planning and Installation Guide GA27 4339 02 ...
Page 6: ...iv BladeCenter T Types 8720 and 8730 Planning and Installation Guide ...
Page 8: ...vi BladeCenter T Types 8720 and 8730 Planning and Installation Guide ...
Page 12: ...Index 121 x BladeCenter T Types 8720 and 8730 Planning and Installation Guide ...
Page 14: ...xii BladeCenter T Types 8720 and 8730 Planning and Installation Guide ...
Page 102: ...88 BladeCenter T Types 8720 and 8730 Planning and Installation Guide ...
Page 130: ...116 BladeCenter T Types 8720 and 8730 Planning and Installation Guide ...
Page 134: ...120 BladeCenter T Types 8720 and 8730 Planning and Installation Guide ...
Page 138: ...124 BladeCenter T Types 8720 and 8730 Planning and Installation Guide ...
Page 139: ......
Page 140: ... Printed in USA GA27 4339 02 ...