Page 4: ...Notices manual G229 9054 and the IBM Environmental Notices and User Guide Z125 5823 This edition applies to IBM Power Systems servers that contain the POWER8 processor and to all associated models Cop...

Page 5: ...t priorities for the 8286 41A or 8286 42A 19 PCIe adapter placement rules and slot priorities for the EMX0 PCIe Gen3 I O expansion drawer 32 Related procedures for PCI adapter placement 40 Finding the...

Page 6: ...iv Power Systems PCIe adapter placement for the 8247 42L 8286 41A or 8286 42A...

Page 7: ...tional copies of safety information documentation can be obtained by calling the IBM Hotline at 1 800 300 8751 German safety information Das Produkt ist nicht f r den Einsatz an Bildschirmarbeitspl tz...

Page 8: ...urn off everything unless instructed otherwise 2 For AC power remove the power cords from the outlets 3 For racks with a DC power distribution panel PDP turn off the circuit breakers located in the PD...

Page 9: ...mperatures will exceed the manufacturer s recommended ambient temperature for all your rack mounted devices v Do not install a unit in a rack where the air flow is compromised Ensure that air flow is...

Page 10: ...ial hazards v Verify that the route that you choose can support the weight of the loaded rack cabinet Refer to the documentation that comes with your rack cabinet for the weight of a loaded rack cabin...

Page 11: ...DANGER Rack mounted devices are not to be used as shelves or work spaces L002 L003 1 2 or 1 2 or 1 2 3 4 or Safety notices ix...

Page 12: ...pped with multiple AC power cords or multiple DC power cables To remove all hazardous voltages disconnect all power cords and power cables L003 L007 CAUTION A hot surface nearby L007 L008 x Power Syst...

Page 13: ...tacle Although shining light into one end and looking into the other end of a disconnected optical fiber to verify the continuity of optic fibers many not injure the eye this procedure is potentially...

Page 14: ...load v Do not use on uneven surface incline or decline major ramps v Do not stack loads v Do not operate while under the influence of drugs or alcohol v Do not support ladder against LIFT TOOL v Tipp...

Page 15: ...ing interfaces only Type 2 or Type 4 ports as described in GR 1089 CORE and require isolation from the exposed OSP cabling The addition of primary protectors is not sufficient protection to connect th...

Page 16: ...xiv Power Systems PCIe adapter placement for the 8247 42L 8286 41A or 8286 42A...

Page 17: ...Port 10 GbE SFN6122F Adapter EC42 PCIe2 3D Graphics Adapter x1 EC47 PCIe gen3 x16 GPU Adapter EN0W PCIe2 2 port 10 GbE BaseT RJ45 Adapter PCIe adapter placement rules and slot priorities for the 8247...

Page 18: ...ule 1 Chip 1 Table 3 lists the features provided by the PCIe3 switches Table 3 PCIe generation 3 switches in the system Features provided PCIe3 Switch 1 PCIe3 Switch 2 Lanes and ports 32 lane 8 ports...

Page 19: ...t available if a GPU adapter is in slot 3 P1 C3 Slot 4 P1 C51 PCIe3 x16 Processor Module 2 Chip 0 PHB0 Full height full length Yes Yes Yes 11 No Yes Yes Slot 5 P1 C61 PCIe3 x16 Processor Module 1 Chip...

Page 20: ...support enhanced error handling EEH v All PCIe slots are hot swappable and support concurrent maintenance PCIe adapters placement rules Use this information while selecting slots for installing PCIe a...

Page 21: ...s supported Slot priorities Maximum number of adapters supported Slot priorities Maximum number of adapters supported 5748 POWER GXT145 PCI Express Graphics Accelerator FC 5748 CCIN 5748 Adapter FRU n...

Page 22: ...Supported on Firmware level 7 8 or later 11 10 8 7 6 5 6 1 11 3 10 8 7 6 2 5 4 10 Not supported Not supported EC46 PCIe2 4 port USB 3 0 Adapter FC EC46 CCIN 58F9 Adapter FRU number 00E2932 v PCIe2 2...

Page 23: ...g systems 5 6 7 102 8 11 6 1 2 3 4 5 6 7 10 8 Not supported Not supported EC57 PCIe3 3 2 TB NVMe Flash Adapter FC EC56 and EC57 CCIN 58CC Adapter FRU number 00MH993 v PCIe3 x4 v Short low profile FC E...

Page 24: ...0 Gb EDR Infiniband Adapter x16 FC EC3U CCIN 2CEB Adapter FRU number 00WT013 v PCIe3 x16 v Short with full height tail stock v OS support Linux operating systems 5 6 2 5 2 6 4 4 5 2 6 4 2 EC3M PCIe3 2...

Page 25: ...f two expansion drawer cables v An expansion drawer cable pair attaches to one IO module FC EMXF in the EMX0 PCIe Gen3 I O expansion drawer v Two adapters are required to attach the EMX0 PCIe Gen3 I O...

Page 26: ...8 v Short with full height tailstock v Field Programmable Gate Array FPGA accelerator adapter v One PCIe x8 or x16 slot per adapter v OS support AIX and Linux operating systems 6 5 2 6 2 5 4 4 Not sup...

Page 27: ...ion throughput v CPU offload and CAPI interface with negligible software load v OS support Linux operating systems 5 6 1 5 2 6 4 2 4 1 EJ1P PCIe1 SAS Tape DVD Dual port 3 Gb x8 Adapter FC EJ1P and EJ1...

Page 28: ...system 9 11 10 8 7 6 5 7 9 1 11 3 10 8 7 6 5 4 10 Not supported Not supported EL50 PCIe3 2 port 56 Gb FDR IB Adapter x16 FC EL50 CCIN 2CE7 Adapter FRU number 00RX852 v PCIe3 x16 v Short with full hei...

Page 29: ...ports network interface controller NIC and RoCE services v OS support Red Hat Enterprise Linux and SUSE Linux Enterprise Server 5 6 7 8 10 11 6 5 2 6 4 7 1 8 3 10 11 10 Not supported Not supported EL5...

Page 30: ...CNA v Provides network interface controller NIC v Single root I O virtualization SR IOV capable v OS support Red Hat Enterprise Linux and SUSE Linux Enterprise Server 9 5 6 7 8 10 11 7 9 5 2 6 4 7 1...

Page 31: ...rs can be installed singly or in pairs v OS support Red Hat Enterprise Linux and SUSE Linux Enterprise Server 5 6 7 8 10 11 6 5 2 6 4 7 1 8 3 10 11 10 Not supported Not supported EL5B PCIe3 16 Gb 2 po...

Page 32: ...ight tailstock v Transfer speed of 6 Gbps v No write cache v Adapters can be installed singly or in pairs v OS support Red Hat Enterprise Linux and SUSE Linux Enterprise Server 5 6 7 8 10 11 6 5 2 6 4...

Page 33: ...1 Gb RJ45 ports v NIC network convergence adapter v Local are network LAN adapter 9 5 6 7 8 10 11 7 9 5 2 6 4 7 1 8 3 10 11 11 9 5 2 6 4 7 1 8 3 10 11 2 EN0W PCIe2 2 port 10 GbE BaseT RJ45 Adapter FC...

Page 34: ...ggable SFP and include four optical SR transceivers v Ethernet network interface controller NIC function v Single root I O virtualization SR IOV capable v OS support AIX IBM i and Linux operating syst...

Page 35: ...heral Component Interconnect PCI Express PCIe adapters that are supported for the 8286 41A or 8286 42A system PCIe slot descriptions for the 8286 41A and 8286 42A The 8286 41A and 8286 42A system prov...

Page 36: ...oncurrent maintenance through I2C bus Yes Yes End to end cyclic redundancy check CRC and Poison bit error checking Supported Supported Data path parity Supported Supported Memory error correction Supp...

Page 37: ...or 8286 42A 1 processor 8286 42A 2 processors Slot 1 P1 C21 6 PCIe3 x8 Processor Module 2 Chip 1 PHB1 Full height half length or Short low profile No Yes Yes 5 No Yes Slot 2 P1 C31 PCIe3 x16 Processor...

Page 38: ...ux partitions the I O Adapter Enlarged Capacity setting should be disabled 4The I O Adapter Enlarged Capacity assignment order value is 5 for one processor or 10 for two processors 5The I O Adapter En...

Page 39: ...tem Table 9 PCIe adapter slot priorities and maximum adapters supported in the 8286 41A or 8286 42A system Feature code Description 8286 41A or 8286 42A 1 processor 8286 42A1 2 processors Slot priorit...

Page 40: ...t tailstock v Extra high bandwidth If only one port is planned to be active in normal operation the adapter is counted as an extra high bandwidth adapter If both ports are planned to be active the ada...

Page 41: ...r FC 5785 CCIN 57D2 Adapter FRU number 46K6734 v PCIe x1 v Short with full height tailstock v OS support AIX and Linux operating systems 102 8 5 6 4 102 8 1 3 2 4 5 6 8 5805 PCIe 380 MB Cache Dual x4...

Page 42: ...VIOS and Linux operating systems v VIOS supported NIC capability only 5 6 7 8 102 11 6 5 2 6 4 7 1 8 3 102 11 10 EC33 PCIe3 2 port 56 Gb FDR IB Adapter x16 FC EC33 CCIN 2CE7 Adapter FRU number 00RX852...

Page 43: ...7 6 5 6 1 11 3 102 8 7 6 2 5 4 10 EC55 PCIe3 1 6 TB NVMe Flash Adapter FC EC54 and EC55 CCIN 58CB Adapter FRU number 00MH991 v PCIe3 x4 v Short low profile FC EC54 v Short with full height tailstock...

Page 44: ...er 000NK006 v PCIe3 x8 v Short with full height tailstock v Field Programmable Gate Array FPGA accelerator adapter v One PCIe x8 or x16 slot per adapter v OS support AIX and Linux operating systems 5...

Page 45: ...s an extra high bandwidth adapter If both ports are planned to be active the adapter must be treated as two extra high bandwidth adapters v OS support Linux operating system 5 6 7 8 102 11 6 5 2 6 4 7...

Page 46: ...N0S PCIe2 4 port 10 Gb 1 GbE SR RJ45 Adapter FC EN0S CCIN 2CC3 Adapter FRU number 00E2715 Part number Full height tailstock 00E2863 Part number Low profile tailstock 00E2720 v PCIe2 x8 v Short with fu...

Page 47: ...pper Adapter FC EN17 CCIN 2CE4 Adapter FRU number 00ND463 full height tailstock part number 00ND465 v PCIe3 x8 v Short with full height tailstock v High bandwidth v 10 Gb SFP ports can function in the...

Page 48: ...ent is required PCIe adapter placement rules and slot priorities for the EMX0 PCIe Gen3 I O expansion drawer Find information about the placement rules and slot priorities for the Peripheral Component...

Page 49: ...e3 x8 No No No Slot 7 P2 C1 PCIe3 x16 Yes Yes Yes3 Slot 8 P2 C2 PCIe3 x8 No Yes2 No Slot 9 P2 C3 PCIe3 x8 No No No Slot 10 P2 C4 PCIe3 x16 Yes1 Yes2 No Slot 11 P2 C5 PCIe3 x8 No Yes2 No Slot 12 P2 C6...

Page 50: ...nhanced error handling EEH v All PCIe slots are hot swappable and support concurrent maintenance PCIe adapters placement rules Use this information while selecting slots for installing PCIe adapters i...

Page 51: ...12 2 8 3 9 5 11 6 12 1 7 4 10 6 6 0 5729 PCIe2 FH 4 port 8 Gb74Y3467 Fibre Channel Adapter FC 5729 CCIN 5729 Adapter FRU number 74Y3467 1 7 4 10 2 8 3 9 5 11 6 12 6 6 0 5735 8 Gb PCI Express Dual port...

Page 52: ...11 3 9 6 12 1 7 4 10 6 6 6 5913 PCIe2 1 8 GB Cache RAID SAS Tri port 6 Gb Adapter FC 5913 CCIN 57B5 Adapter FRU number 00J0596 1 7 4 10 2 8 3 9 5 11 6 12 6 6 6 EC28 PCIe2 2 port 10 GbE RoCE SFP adapte...

Page 53: ...or all other machine type models 1 7 4 10 3 9 6 12 4 4 4 EJ14 PCIe3 12 GB Cache RAID PLUS SAS Adapter Quad port 6 Gb x8 FC EJ14 CCIN 57B1 Adapter FRU number 01DH742 1 7 4 10 3 9 6 12 4 4 4 EJ1P PCIe1...

Page 54: ...6 0 EL57 PCIe2 4 port 10 Gb FCoE and 1 GbE Copper and RJ45 Adapter FC EL57 CCIN 2CC1 Adapter FRU number 00E8140 1 7 4 10 2 8 3 9 5 11 6 12 6 6 0 EL58 8 Gb PCI Express Dual port Fibre Channel Adapter...

Page 55: ...port 10 Gb 1 GbE Copper SFP RJ45 Adapter FC EN0U CCIN 2CC3 Adapter FRU number 00E2715 low profile tailstock 00E2720 1 7 4 10 2 8 3 9 5 11 6 12 6 6 0 EN0W PCIe2 2 port 10 GbE BaseT RJ45 Adapter FC EN0...

Page 56: ...IBM i session and sign on If you have more than one system start a session on the system that is being upgraded and for which you have service tools authority To find the current system configuration...

Page 57: ...rules and slot priorities for the 8286 41A or 8286 42A on page 19 v Yes Do the following tasks a Type 9 for the System Expansion Unit field and press Enter b Repeat steps 7 11 for each expansion unit...

Page 58: ...42 Power Systems PCIe adapter placement for the 8247 42L 8286 41A or 8286 42A...

Page 59: ...efore this statement may not apply to you This information could include technical inaccuracies or typographical errors Changes are periodically made to the information herein these changes will be in...

Page 60: ...nsitive or critical operations Users should periodically check IBM s support websites for updated information and fixes applicable to the system and related software Homologation statement This produc...

Page 61: ...www ibm com able Privacy policy considerations IBM Software products including software as a service solutions Software Offerings may use cookies or other technologies to collect product usage inform...

Page 62: ...y and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause ha...

Page 63: ...dard of the VCCI Council If this equipment is used in a domestic environment radio interference may occur in which case the user may be required to take corrective actions Japan Electronics and Inform...

Page 64: ...China Declaration This is a Class A product In a domestic environment this product may cause radio interference in which case the user may need to perform practical action Electromagnetic Interference...

Page 65: ...ustimmung von IBM ver ndert bzw wenn Erweiterungskomponenten von Fremdherstellern ohne Empfehlung von IBM gesteckt eingebaut werden EN 55022 EN 55032 Klasse A Ger te m ssen mit folgendem Warnhinweis v...

Page 66: ...ordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does...

Page 67: ...esponsibility for any failure to satisfy the protection requirements resulting from a non recommended modification of the product including the fitting of non IBM option cards European Community conta...

Page 68: ...taatenund h lt die Grenzwerte der EN 55022 EN 55032 Klasse B ein Um dieses sicherzustellen sind die Ger te wie in den Handb chern beschrieben zu installieren und zu betreiben Des Weiteren d rfen auch...

Page 69: ...that all proprietary notices are preserved You may not distribute display or make derivative works of these publications or any portion thereof without the express consent of IBM Commercial Use You m...

Page 70: ...54 Power Systems PCIe adapter placement for the 8247 42L 8286 41A or 8286 42A...

Page 71: ......

Page 72: ...IBM...

Reviews: