background image

Leadership enterprise server with significantly lower cost of ownership in a highly available and 
expandable, rack-dense, 1U dual-socket server

 

Please see the Legal Information section for important notices and information. 

enable higher-performance hardware RAID support, and allows the x3550 M3 to offer 

five

 

RAID levels standard: 

RAID-0/1/10/5

/

50

 (and optionally 

6/60 

with

 SED)

.  

  The 

five USB 2.0

 ports (two front, two rear, one internal) are up to 

40X

 faster

2

 than older 

USB 

1.1

 ports. This provides speedy access to external HDDs (non-arrayed), optical drives, tape 

drives, and other USB devices. Two ports are on the front of the unit and two are on the back. 
The internal port supports a flash drive with embedded hypervisor. 

  A choice of up to 

eight

 

2.5-inch hot-swap SAS/SATA 

HDDs

 

or

 solid-state drives

, or 

four

 

2.5-inch drives and 

one

 internal optical drive, offer a variety of

 

storage options. The SAS and 

SATA HDD models provide a maximum of 

8.0TB

 of internal 

hot-swap

 storage. The x3550 M3 

supports a mix of hot-swap SAS, SATA and SSD drives. 

  Alternatively, direct-attach, network-attached storage (NAS), or iSCSI or Fibre Channel-

attached storage can be attached using IBM

 System Storage™

 servers. 

 

Manageability / Security 

Powerful systems management features simplify local and remote management of the x3550 M3:  

  The x3550 M3 includes an 

Integrated

 

Management Module (IMM)

 to monitor server 

availability, perform Predictive Failure Analysis, etc., and trigger IBM 

Systems Director

 alerts. 

The IMM performs the functions of both the Baseboard Management Controller (

BMC

) of 

earlier systems and the 

Remote Supervisor Adapter II

 and is upgradeable to 

remote 

presence/cKVM.

  

  An optional Virtual Media Key provides additional systems management capabilities, including 

Web-based out-of-band control; virtual floppy and optical drive support; Windows “blue 
screen” error capture; LDAP and SSL support; and remote redirection of PCI video, text, 
keyboard and mouse (cKVM). And it does all this without consuming a valuable adapter slot. 

  Integrated  industry-standard  Unified  Extensible  Firmware  Interface  (

UEFI

)  next-generation 

BIOS. New capabilities include:  

–  Human readable event logs – no more beep codes 

–  Complete setup solution by allowing adapter configuration function to be moved into UEFI 

–  Complete out-of-band coverage by Advance Settings Utility to simplify remote setup 

  Integrated 

Trusted Platform Module (TPM) 1.2

 support.  

  Intel

 Trusted Execution Technology

 (TXT) support for more secure processing, and 

industry-standard 

AES NI

 support for faster, stronger encryption (in 5600 Series processors 

only). 

  Integrated 

IPMI 2.0

 support alerts IBM Systems Director to anomalous environmental factors, 

such as voltage and thermal conditions. It also supports 

highly secure remote power 

control

 using data encryption. 

 

Text Console Redirection 

support allows the administrator to remotely view x3550 M3 text 

messages over Serial or LAN. 

 

IBM

 

Systems

 

Director 6.1x 

is included for proactive systems management. IBM Systems 

Director comes with a portfolio of tools, including 

IBM Systems Director Active Energy 

Manager

Service and Support Manager

, and others. In addition, IBM Systems Director 

offers extended systems management tools for additional server management and increased 
availability. When a problem is encountered, IBM Systems Director can issue administrator 
alerts via e-mail, pager, and other methods. 

  IBM

 Systems Director Active Energy Manager

™, an IBM-exclusive, is designed to take 

advantage of new system power management features, by providing actual realtime energy 
monitoring and reporting features.

 

 

 

 

 

 

 

 

Availability and Serviceability 

The x3550 M3 provides many features to simplify serviceability and increase system uptime:  

  x3550 M3 servers offer 

Chipkill 

ECC memory protection

3

 (when using x4 DIMMs). Chipkill 

memory is up to 

16X

 better than standard ECC memory at correcting memory errors. This can 

help reduce downtime caused by memory errors. 

  The x3550 M3 offers selectable 

memory mirroring

 for redundancy in the event of a non-

correctable memory failure 

 

Toolless

 

cover removal

 provides easy access to upgrades and serviceable parts. Similarly, 

the Virtual Media Key and the 

ServeRAID

 controller can be installed and replaced without 

tools. This means less time (and therefore less money) spent servicing the x3550 M3. 

                                                                                                                                                                                           

2

 Data transfer rates may be less than the maximum possible. 

3

 Chipkill protection is supported with x4 DDR3 DIMMs, but not x8 DIMMs. 

Summary of Contents for 7944E2U

Page 1: ...UDIMM memory and provides Chipkill ECC Error Checking and Correcting protection for high performance and reliability For even higher levels of availability the x3550 M3 also offers memory mirroring Up to 4 integrated high speed Gigabit Ethernet controllers are available offering TOE TCP Offload Engine support on Microsoft Windows as are two high performance adapter slots PCIe x16 The x3650 M3 offe...

Page 2: ...nction with IMM to govern fan rotation which can help save money at lower altitudes because the fans do not have to spin at high speed Two high speed PCIe x16 adapters Gen 2 slots offer investment protection by supporting high performance adapters such as 10Gb Ethernet Fibre Channel and InfiniBand cards none of which will run in older 33MHz and 66MHz conventional PCI slots The integrated ServeRAID...

Page 3: ...bilities include Human readable event logs no more beep codes Complete setup solution by allowing adapter configuration function to be moved into UEFI Complete out of band coverage by Advance Settings Utility to simplify remote setup Integrated Trusted Platform Module TPM 1 2 support Intel Trusted Execution Technology TXT support for more secure processing and industry standard AES NI support for ...

Page 4: ...memory access speeds and energy draw including 130W 6 core Xeon 5600 model X5680 running at 3 33GHz with impressive performance watt 21 67W per core 6 4GTps QPI speed 12MB of L3 processor cache 1333MHz memory access 2 threads per core and Intel Turbo Boost technology 95W 6 core Xeon 5600 models X5650 or X5670 running at 2 66 or 2 93GHz respectively with reduced draw and impressive performance watt...

Page 5: ...core processors offer considerably higher performance than a same speed Xeon processor with 2 cores Turbo Boost Technology increases performance by translating the temperature power and current head room into higher frequency It will dynamically increase by 133MHz for short and regular intervals until the upper limit is met or the maximum possible upside for the number of active cores is reached T...

Page 6: ...tion This huge improvement is mainly due to the dual integrated memory controllers and faster DDR3 1333MHz memory Throughput at 800MHz is 25 gigabytes per second GBps at 1066MHz it s 32GBps and at 1333MHz it s 35GBps This improvement translates into improved application performance and scalability Memory interleaving refers to how physical memory is interleaved across the physical DIMMs A balanced...

Page 7: ...ing system support is required DDR3 memory is currently available in 2GB 4GB and 8GB RDIMMs or 2GB UDIMMs 16GB RDIMMs and 4GB UDIMMs are planned for 2Q 2010 DIMMs are installed individually not in pairs However for performance reasons in a 2 processor system it s best to install a DIMM per processor Maximum memory capacity and speed in 2 processor configurations include Memory Frequency DIMMs per ...

Page 8: ...00GB 2 4TB maximum 2 5 inch Hot Swap or Simple Swap SSDs 50GB High IOPS 400GB maximum High I O Performance Offers up to 8X more IOPS than HDDs 67 33 read write OLTP transaction base mix Optimized for heavy mix of read and write operations such as transaction processing media streaming surveillance file copy logging backup recovery and business Intelligence Lower Cost IOPS Performance Yields better...

Page 9: ...et TOE processor It also supports highly secure remote power management using IPMI 2 0 plus Wake on LAN and PXE Preboot Execution Environment flash interface Optional PCI adapters offering failover and load balancing between adapters are available for added throughput and increased system availability Integrated quad Gb Ethernet ports Up to four Gb Ethernet ports ideal for virtualization and I O i...

Page 10: ...he IBM fans to run at lower speeds at lower altitudes Why not simply run the fans at 100 capacity all the time For several good reasons to reduce the ambient noise reduce the wear and tear on the fans and reduce the server power draw The reduction in ambient noise and power draw may be relatively minor for a single server but put dozens or hundreds in a data center and it can make a big difference...

Page 11: ...nt Capabilities The x3550 M3 has a high level of systems management capabilities that are well suited to remote locations as well as to stand alone environments Features include UEFI IMM IBM ToolsCenter IBM Systems Director Active Energy Manager for x86 Automatic Server Restart Wake on LAN support PXE support text console redirect Predictive Failure Analysis and IBM Systems Director The IMM provid...

Page 12: ...gned so that no more than five minutes can pass before the server is restarted Wake on LAN permits the server to be remotely powered on if it has been shut off Once powered up the server can be controlled across the network using the Preboot Execution Environment PXE Like Wake on LAN PXE is system firmware It enables software such as the optional IBM Remote Deployment Manager to take control of a ...

Page 13: ...report inventory changes to IBM All information sent to IBM is stored in a highly secure database and used for improved problem determination Additional services include hardware warranty upgrades and factory installed Product Customization Services PCS such as asset tagging hardware integration software imaging and operating systems personalization IBM offers extensive technical support by phone ...

Page 14: ...RAID controllers offer enhanced performance due to onboard processors and cache Because IBM ServeRAID controllers can help significantly improve data transfer rates this technology is extremely effective when implementing demanding transaction oriented applications By employing the advanced fault tolerance of IBM ServeRAID technology companies can effectively implement networked business systems t...

Page 15: ... Inside View Rear View Video Port Serial Port Adapter Slot Adapter Slot Fast Ethernet Port for IMM USB Ports Optional Gb Ethernet Ports Hot Swap Power Supply Standard Gb Ethernet Ports Empty Power Supply Bay Hexagonal Ventilation Holes Hot Swap Power Supplies USB Hypervisor Key Hot Swap HDD Bays Hot Swap Fan Packs 18 DIMM Slots Processor Socket ServeRAID Controller Gb Ethernet Adapter Slot Adapter...

Page 16: ... H2x 4 8GTps A2x B2x of processors standard maximum 2 2 F2x 1 2 all other models Hyper Threading Technology supported Yes 2 threads per core C2x D2x F2x G2x H2x J2x M2x N2x No A2x B2x Turbo Boost Technology supported Yes C2x D2x F2x G2x H2x J2x M2x N2x No A2x B2x Internal L3 cache 12MB 1 shared 12MB cache all other models 4MB 1 shared 4MB cache A2x B2x Chipset Intel 5520 Standard memory 192GB maxi...

Page 17: ...orage technology Hot swap SAS SATA also hot swap or simple swap SSD Integrated disk controller LSI 1068 of disk drives supported per port 1 Integrated RAID controller standard ServeRAID BR10il v2 no cache RAID 0 1 1E 3Gbps supports 4 drives A2x ServeRAID M1015 no cache optional battery RAID 0 1 10 optional RAID 5 with SED 6Gbps supports 16 drives B2x C2x D2x H2x N2x ServeRAID M5014 256MB cache opt...

Page 18: ...ed of fans modules standard maximum 6 6 F2x 5 6 all other models Hot swap redundant fans supported Yes standard Rack mount method Slides and Cable Management Arm provided standard Maximum altitude 7 000 ft 2 133 m Operating temperature range 50 95º F 10 35º C up to 3 000 ft 914 4 m 50 90º F 10 32º C 3 000 ft to 7 000 ft 914 4m to 2 133m Dimensions HWD weight 1 69 43mm H 17 3 440mm W 28 0 711 4mm D...

Page 19: ... Fast communications Integrated dual Gigabit Ethernet controllers standard supporting load balancing and failover two additional NICs optional Fast I O Two PCIe x16 adapter slots replaceable with two PCI X 133 slots Flexibility Large memory capacity Up to 192GB of registered DDR2 DIMMs in 18 DIMM slots Up to 8 2 5 inch hot swap SAS SATA HDDs or SSDs or simple swap SSDs Choice of disk storage Up to...

Page 20: ... which each server is best suited Important Nice to Have Can do without 1 2 3 Best Better Good Theme Key Workloads Scalability Floating Point Performance Memory Throughput Integer Performance I O and Storage Density High Availability Systems Management Security Distributed Deployment x3250 M3 x3550 M3 x3650 M3 x3690 X5 x3755 x3850 X5 x3950 X5 Cluster HPC 3 1 1 2 2 1 3 3 3 3 Modeling Simulation 2 1...

Page 21: ...oduct and service names may be trademarks or service marks of others IBM reserves the right to change specifications or other product information without notice References in this publication to IBM products or services do not imply that IBM intends to make them available in all countries in which IBM operates IBM PROVIDES THIS PUBLICATION AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESS OR IMPLI...

Reviews: