Note:
You can reconnect the cables to the hard disk drive backplane before installing the
backplane onto the brackets or you can connect the cables after you install the backplane, if that is
easier for you.
Hard disk drive
backplane
Backplane
bracket slots
Figure 77. Hard disk drive backplane installation
Step 13. Connect the SATA power cable, the SATA signal cable, and the configuration cable to the hard disk
drive backplane (see
“Internal cable routing and connectors” on page 44
).
Note:
The configuration cable will not be shipped with this option. The configuration cable is
already installed from the system board to the original backplane, this cable is two drops chained
cable. Connect the end of this cable to the newly-added 4 Pac HDD backplane.
Step 14. Connect the other end of the SATA signal cable to the connector on the SAS/SATA adapter (see
Step 8 in “Installing a ServeRAID SAS/SATA controller on the SAS/SATA RAID riser card”
).
Step 15. Reinstall the hard disk drives and filler panels.
If you have other devices to install or remove, do so now. Otherwise, go to
“Completing the installation” on
.
Installing a second microprocessor and heat sink
Use this information to install a second microprocessor and heat sink.
The following notes describe the type of microprocessor that the server supports and other information that
you must consider when you install a microprocessor and heat sink:
• Microprocessors are to be installed only by trained service technicians.
Important:
Always use the microprocessor installation tool to remove a microprocessor. Failing to use
the microprocessor installation tool may damage the microprocessor sockets on the system board. Any
damage to the microprocessor sockets may require replacing the system board.
94
System x3550 M3Installation and User's Guide
Summary of Contents for 7944
Page 1: ...System x3550 M3 Installation and User s Guide Machine Type 4254 and 7944...
Page 44: ...Figure 14 Server components 34 System x3550 M3Installation and User s Guide...
Page 114: ...104 System x3550 M3Installation and User s Guide...
Page 132: ...122 System x3550 M3Installation and User s Guide...
Page 136: ...126 System x3550 M3Installation and User s Guide...
Page 148: ...138 System x3550 M3Installation and User s Guide...
Page 149: ......
Page 150: ...Part Number 00KC032 Printed in China 1P P N 00KC032 1P00KC032...