background image

pSeries and p5 Adapters feature numbers 6203, 6205, the Integrated ULTRA2 SCSI Adapter, feature number 5703, 5710,
5711, or 5712 with one 7212 Model 102 per adapter port

7212 Bay-A
Feature

    7212 Bay-B Feature number

number

1204 1100 1101 1102 1103 1104 1105 1106 1107 1108 1109

1204/9204

NA

10.0

1.5

1.5

10.0 10.0 10.0 10.0 10.0 10.0 10.0

1100

10.0 10.0

1.5

1.5

10.0 10.0 10.0 10.0 10.0 10.0 10.0

1101

1.5

1.5

1.5

1.5

1.5

1.5

1.5

1.5

1.5

1.5

10.0

1102

1.5

1.5

1.5

1.5

1.5

1.5

1.5

1.5

1.5

1.5

10.0

1103

10.0 10.0

1.5

1.5

10.0 10.0 10.0 10.0 10.0 10.0 10.0

1104

10.0 10.0

1.5

1.5

10.0 10.0 10.0 10.0 10.0 10.0 10.0

1105

10.0 10.0

1.5

1.5

10.0 10.0 10.0 10.0 10.0 10.0 10.0

1106

10.0 10.0

1.5

1.5

10.0 10.0 10.0 10.0 10.0 10.0 10.0

1107

10.0 10.0

1.5

1.5

10.0 10.0 10.0 10.0 10.0 10.0 10.0

1108

10.0 10.0

1.5

1.5

10.0 10.0 10.0 10.0 10.0 10.0 10.0

1109

10.0 10.0

1.5

1.5

10.0 10.0 10.0 10.0 10.0 10.0 10.0

Note:

Cable lengths are in meters.

pSeries and p5 Adapters feature numbers 6203, 6205, the Integrated ULTRA2 SCSI Adapter, feature number 5703, 5710,
5711, or 5712 with two 7212 Model 102s per adapter port or one 7212 Model 102 and one 72xx external device per
adapter port

7212 Bay-A
Feature

    7212 Bay-B Feature number

number

1204 1100 1101 1102 1103 1104 1105 1106 1107 1108 1109

1204/9204

NA

9.0

NS

NS

9.0

9.0

9.0

NS

9.0

9.0

9.0

1100

9.0

9.0

NS

NS

9.0

9.0

9.0

NS

9.0

9.0

9.0

1101

NS

NS

NS

NS

NS

NS

NS

NS

NS

NS

NS

1102

NS

NS

NS

NS

NS

NS

NS

NS

NS

NS

NS

1103

9.0

9.0

NS

NS

9.0

9.0

9.0

NS

9.0

9.0

9.0

1104

9.0

9.0

NS

NS

9.0

9.0

9.0

NS

9.0

9.0

9.0

1105

9.0

9.0

NS

NS

9.0

9.0

9.0

NS

9.0

9.0

9.0

1106

NS

NS

NS

NS

NS

NS

NS

NS

NS

NS

NS

1107

9.0

9.0

NS

NS

9.0

9.0

9.0

NS

9.0

9.0

9.0

1108

9.0

9.0

NS

NS

9.0

9.0

9.0

NS

9.0

9.0

9.0

1109

9.0

9.0

NS

NS

9.0

9.0

9.0

NS

9.0

9.0

9.0

Note:

Cable lengths are in meters.

Notes:

When using two 7212 Storage Enclosures per adapter
port, the first 7212 must have the single SCSI bus
feature (#9207). The second 7212 may have either the
single SCSI bus feature (#9207) or split SCSI bus
features (#1208 or #9206).

7212 Storage Enclosures, manufactured before
March 2002, 

had a single SCSI bus, equivalent to

feature number 9207.

iSeries and i5 cables

One SCSI cable must be specified with the 7212 if the
single bus feature number 9207 is specified. If the split
bus feature number 1208 or 9206 is ordered, one SCSI
cable 

must

 be specified for each storage device

(maximum of 2 per 7212). The cables must be specified
on the initial plant order. The following table shows the
various SCSI cable feature numbers that can be ordered
depending on the host iSeries system adapter to which
the 7212 Model 102 will be attached.

Note:

For iSeries and i5, the 7212 Model 102 must be the

only device attached to the external bus.

iSeries SCSI

Cable

Feature number

adapter feature

length

plant

both

2768

1.5 m

9750

5300

2.5 m

9752

5302

5702, 5705

0.5 m

9765

5600

5703, 5712

1.5 m

9761

5601

2.5 m

9762

5602

4.5 m

9764

5604

  10.0 m

9760

5610

Supplies:

The part numbers for additional supplies for the

7212 Model 102 feature number 1109 are:

IBM part
number

Supply item

08L9870

200 GB Ultrium 2 Data Cartridge

24R0395

LTO Test Cartridge

35L2086

LTO Cleaning Cartridge

For additional tape data or cleaning cartridges refer to

http://www.storage.ibm.com/media

For additional media supplies, refer to

http://www.storage.ibm.com/media

To purchase IBM-branded media and media supplies, call
888-IBM-MEDIA (426-6334) in the U.S. and Canada, or go
to

http://www.storage.ibm.com/media

105-397

-6-

Summary of Contents for 7212 Model 102

Page 1: ...he following previously announced 7212 Model 102 features VXA 2 Tape Drive DAT72 Tape Drive SLR60 Tape Drive SLR100 Tape Drive DVD ROM Drive and DVD RAM 2 Drive Key prerequisites Refer to the Description section Planned availability date October 14 2005 At a glance The Half High LTO 2 Tape Drive feature for the IBM 7212 Model 102 is designed to offer excellent flexibility capacity and function It ...

Page 2: ...del 102 is limited to servers that support adapter feature numbers 2768 5702 5703 5705 and 5712 and with OS 400 V5 2 or later or Linux as listed at the end of this section i5 servers require IBM i5 OS V5 3 or later or Linux as listed at the end of this section Linux support SUSE LINUX Enterprise Server 9 for POWER Red Hat Enterprise LINUX AS for POWER V3 Product positioning New pSeries and iSeries...

Page 3: ...rder their publications via the Publication Center Services Integrated Technology Services IBM services include business consulting outsourcing hosting services applications and other technology management These services help you learn about plan install manage or optimize your IT infrastructure to be an on demand business They can help you integrate your high speed networks storage systems applic...

Page 4: ...r attachment to the PCI Ultra 2 SCSI LVD low voltage differential or single ended 64 bit Adapter 6205 on the following pSeries and RS 6000 systems 7017 S80 pSeries 680 7017 S85 pSeries 620 7025 6F0 6F1 7025 F50 F80 H70 pSeries 660 7026 6H0 6H1 6M1 pSeries 640 7026 B80 7026 H70 H80 M80 7044 170 270 7046 B50 The drive features of the 7212 Model 102 are supported for attachment to the PCI Single Ende...

Page 5: ... PCI X RAID Controller 5703 PCI X Tape DASD Controller 5705 PCI X ULTRA 320 Tape Controller 5712 For information on which PCI Controller to select refer to the appropriate configurator for prerequisites iSeries cables SCSI cables must be specified on the initial plant order Refer to the Cable orders section for details Software requirements pSeries and p5 servers The Half High LTO 2 Tape Drive fea...

Page 6: ...X Dual Channel 2 5 m 5602 9762 Yes No 5097 ULTRA320 SCSI1 4 5 m 5604 9764 Yes No 5097 RAID Adapter1 10 0 m 5610 9760 Yes No 5097 1 Only 7212 Model 102 with SCSI LVD feature numbers 1100 1103 1104 1105 1106 1107 1108 and 1109 can use the 4 5 m and 10 0 m SCSI cables Feature numbers 1101 and 1102 are single ended devices and are not supported by these cables Also if using the 10 meter cable the 7212...

Page 7: ...he second 7212 may not exceed 7 0 meters pSeries and p5 Adapters feature numbers 6203 6205 the Integrated ULTRA2 SCSI Adapter feature number 5703 or 5712 with one 7212 Model 102 and one 72xx LVD Single Device Bridge Box per adapter port 7212 Bay A and or Bay B Feature number 1204 1100 1101 1102 1103 1104 1105 1106 1107 1108 1109 NA 9 5 NS NS 9 5 9 5 NS 9 5 9 5 9 5 9 5 NS Not supported Note Cable l...

Page 8: ...7 9 0 9 0 NS NS 9 0 9 0 9 0 NS 9 0 9 0 9 0 1108 9 0 9 0 NS NS 9 0 9 0 9 0 NS 9 0 9 0 9 0 1109 9 0 9 0 NS NS 9 0 9 0 9 0 NS 9 0 9 0 9 0 Note Cable lengths are in meters Notes When using two 7212 Storage Enclosures per adapter port the first 7212 must have the single SCSI bus feature 9207 The second 7212 may have either the single SCSI bus feature 9207 or split SCSI bus features 1208 or 9206 7212 St...

Page 9: ...2 102 8101 Plant No Yes HHLTO Gen 2 Multi Cart Kit 7212 102 8103 Plant No Yes Test Cartridge 7212 102 8104 Plant No Yes Cleaning Cartridge 5 pk 7212 102 8105 Plant No Yes Order now To order contact the Americas Call Centers your local IBM representative or your IBM Business Partner To identify your local IBM representative or IBM Business Partner call 800 IBM 4YOU 426 4968 Phone 800 IBM CALL 426 2...

Reviews: