Step 1540-23
The adapter or device is probably defective.
If the supplemental medium is for an adapter, replace the FRUs in the following order:
1. Adapter
2. System board (see notes on page 35)
If the supplemental medium is for a device, replace the FRUs in the following order:
1. Device and any associated cables
2. The adapter to which the device is attached.
Repeat this step until the defective FRU is identified or all the FRUs have been
exchanged.
If the symptom did not change and all the FRUs have been exchanged, call service
support for assistance.
If the symptom has changed, check for loose cards, cables, and obvious problems. If
you do not find a problem, return to “Step 1540-1” on page 64 in this MAP and follow
the instructions for the new symptom.
Go to
″
MAP 0410: Repair Checkout
″
in the
RS/6000
Eserver
pSeries Diagnostic
Information for Multiple Bus Systems.
Step 1540-24
1. Ensure that the diagnostics and the operating system are shut down.
2. Turn off the power.
3. If you have not already done so, configure the service processor with the
instructions in note 6 on page 63 and then return here and continue.
4. Exit the service processor menus and remove the power cords.
5. Remove the service access cover (Model 6E1) or place the drawer (Model 6C1) into
the service position and remove the service access cover.
6. Record the slot numbers of the PCI adapters. Label and record the locations of any
cables attached to the adapters. Disconnect any cables attached to the adapters
and remove all the adapters.
7. Plug in the power cords and wait for OK on the operator panel display.
8. Turn on the power.
Does the system stop with the same error code displayed on the operator panel
that directed you to this MAP step?
NO
Go to “Step 1540-26” on page 82.
YES
Go to “Step 1540-25” on page 82.
Chapter 3. Maintenance Analysis Procedures (MAPs)
81
Summary of Contents for 6C1
Page 1: ...pSeries 610 Model 6C1 and Model 6E1 Service Guide SA38 0599 01 ERserver IBM ...
Page 2: ......
Page 3: ...pSeries 610 Model 6C1 and Model 6E1 Service Guide SA38 0599 01 ERserver IBM ...
Page 14: ...xii Service Guide ...
Page 16: ...xiv Service Guide ...
Page 25: ...Fan Locations 1 2 3 4 1 Fan 1 2 Fan 2 3 Fan 3 4 Fan 4 Chapter 1 Reference Information 7 ...
Page 52: ...34 Service Guide ...
Page 102: ...84 Service Guide ...
Page 129: ...5 Turn the power off then on and retry the boot operation Chapter 4 Checkpoints 111 ...
Page 234: ...216 Service Guide ...
Page 299: ...Replacement Replace in reverse order Chapter 9 Removal and Replacement Procedures 281 ...
Page 324: ...1 2 3 4 5 6 306 Service Guide ...
Page 338: ...320 Service Guide ...
Page 342: ...324 Service Guide ...
Page 366: ...348 Service Guide ...
Page 375: ......
Page 376: ...IBMR Printed in U S A February 2002 SA38 0599 01 ...
Page 377: ...Spine information IBM pSeries 610 Model 6C1 and Model 6E1 Service Guide SA38 0599 01 ...