![IBM 6400 - Model 008 B/W Line-matrix Printer Operator'S Manual Download Page 101](http://html.mh-extra.com/html/ibm/6400-model-008-b-w-line-matrix-printer/6400-model-008-b-w-line-matrix-printer_operators-manual_608026101.webp)
87
Operator’s Guide
Controller self-test and initialization
sequence were halted at <state>, where
<state> is one of 10 numerically coded
messages. Contact an IBM service
representative.
Electrical malfunction of one or more
hammer coils. Contact an IBM service
representative.
Forms thickness lever is raised to the
open position. Lower the forms thickness
lever.
No shuttle movement or the shuttle is
moving at the wrong speed. Make sure
the ribbon is not twisted and the forms
thickness lever is set to match thickness
of media being used. If the fault recurs,
contact an IBM service representative.
Status message displayed when SCS
print job is cancelled. No action
necessary.
Controller board sensors report high
temperatures on the board. Contact an
IBM service representative.
Sensors cannot detect current in fan
circuit. Refer to the
Setup Guide for
correction procedure. If this message
appears on a Pedestal model, contact an
IBM service representative.
046 EC STOPPED AT STATE
<state>
056 HAMMER COIL OPEN
057 CLOSE PLATEN
058 SHUTTLE JAM
059 CANCEL PRINT ACTIVE
060 PRINTER HOT
062 EXHAUST FAN FAULT