17.
Complete a mode 1 connection of two enclosures (A and B) by using YO12 cables (C and D) to an
FC EJ0L SAS adapter pair or an FC EJ14 SAS adapter pair (E) with AA cables (F), as shown in
Figure 17 on page 18, and then continue with “Connecting cables, power cords, and installing
covers” on page 22.
Notes:
v
Each adapter in the SAS adapter pair (C) has access to the other adapter and to all 24 or 48 drive
bays.
v
For SAS adapter pairs, you must attach the cables to the same port on both adapters.
v
Both short legs of the cables must attach to the same side of the enclosure and both long legs of
the cable must attach to the other side of the enclosure.
Figure 16. Mode 1 connection of one ESLL or ESLS storage enclosure by using YO12 cables to an FC EJ0L SAS
adapter pair or an FC EJ14 SAS adapter pair with AA cables
Installing the Model 024, ESLL, or ESLS storage enclosure
17
Summary of Contents for 5147-024