![IBM 4367BDU User Manual Download Page 75](http://html.mh-extra.com/html/ibm/4367bdu/4367bdu_user-manual_608208075.webp)
-
IPMI
Specification
Version
This
nonselectable
item
displays
the
IPMI
specification
version.
-
BMC
Firmware
Version
This
nonselectable
item
displays
the
mini-BMC
firmware
version.
-
BMC
Build
Date
This
nonselectable
item
displays
the
date
that
the
mini-BMC
code
was
built.
-
BMC
Build
Level
This
nonselectable
item
displays
the
version
of
the
mini-BMC
code.
-
Existing
Event
Log
number
This
nonselectable
item
displays
the
number
of
entries
in
the
system-event
log.
-
BMC
POST
Watchdog
This
option
enables
or
disables
the
POST
watchdog.
Disabled
is
the
default
setting.
-
BMC
POST
Watchdog
Timeout
This
option
enables
or
disables
the
mini-BMC
POST
watchdog
timer.
-
System
-
BMC
Serial
Port
Sharing
Select
this
choice
to
specify
whether
the
serial
port
that
the
mini-BMC
uses
is
shared
with
the
other
system
components
or
is
dedicated
to
the
mini-BMC.
When
this
option
is
enabled,
the
mini-BMC
controls
the
serial
port
by
way
of
remote
commands.
If
this
option
is
disabled,
the
serial
port
is
assigned
to
the
mini-BMC,
unless
the
BMC
Serial
Port
Access
Mode
option
is
disabled.
-
BMC
Serial
Port
Access
Mode
Select
this
choice
to
set
the
mini-BMC
access
mode
for
the
system
serial
port.
Shared
is
the
default
setting.
You
can
choose
from
the
following
access
modes:
Shared
The
serial
port
is
available
for
use
by
POST
and
the
operating
system;
however,
the
mini-BMC
can
still
monitor
the
serial
data
for
a
take-control
sequence.
Pre-Boot
The
mini-BMC
has
control
of
the
serial
port
prior
before
the
operating
system
is
booted;
however,
after
the
operating
system
is
booted,
the
mini-BMC
will
not
have
access
to
the
serial
port
until
you
turn
off
the
server
or
reset
the
settings.
Dedicated
The
mini-BMC
has
complete
control
of
the
serial
port.
POST
and
the
operating
system
will
not
be
allowed
to
use
the
serial
port.
Disabled
The
mini-BMC
has
access
to
the
serial
port.
-
Reboot
System
on
NMI
This
option
sets
the
mini-BMC
timer
to
automatically
reboot
the
server
after
an
NMI
occurs.
Enabled
is
the
default
setting.
-
User
Account
Settings
Select
this
choice
to
view
the
user
account
settings
for
the
mini-BMC.
-
BMC
Network
Configuration
Select
this
choice
to
configure
specific
network
settings
for
the
mini-BMC.
Chapter
3.
Configuring
the
server
61
Summary of Contents for 4367BDU
Page 1: ...System x3200 M2 Types 4367 and 4368 User s Guide ...
Page 2: ......
Page 3: ...System x3200 M2 Types 4367 and 4368 User s Guide ...
Page 28: ...14 System x3200 M2 Types 4367 and 4368 User s Guide ...
Page 88: ...74 System x3200 M2 Types 4367 and 4368 User s Guide ...
Page 100: ...86 System x3200 M2 Types 4367 and 4368 User s Guide ...
Page 101: ......
Page 102: ... Part Number 43W7063 Printed in USA 1P P N 43W7063 ...