background image

 
 

© Copyright IBM Corporation 2020, 2021               Customer Install Guide, 100G Switch  

14 

Cloud Pak for Data System 100G spine 
switch description 

 

The IBM Cloud Pak for Data Systems spine switch is a 1U, rack mountable, data center 
switch that delivers up to 32 ports at 100 GbE.  The switch comes as a pretested 
building block loaded with software.   This spine switch is used to interconnect fabric 
switches within systems that contain more than ten 2U chassis or more than twenty 1U 
chassis.   These switches are used in pairs and they typically install in the third rack of a 
Cloud Pak for Data System. 

The switch can be installed in an IBM Cloud Pak rack or a customer supplied rack 
meeting the guidelines in the 

Customer Install Guide, Rack and System

 document 

included on the 

Safety and Regulatory CD

 shipped with your Cloud Pak for Data 

System components.   Additional details can be found in the 

Site Prep Guide 

at the IBM 

Cloud Pak for Data System site. 
 
The switch includes a fresh air duct kit that directs cold air from the front of the rack to 
the power supply side inlets.

 

DO NOT BLOCK ANY INLET OR EXHAUST DUCTS, 

VENTS OR PORTS.   Blocked cooling access will adversely affect the 
performance of your Cloud Pak for Data System and may void your warranty. 

 
Power can be supplied by the available IBM Cloud Pak for Data System PDUs and line 
cords or by customer supplied PDUs meeting the power requirements of the Cloud Pak 
for Data System components. 
 
If this is a customer install, IBM installation services will wire and power the system 
once all racks, power and components are in place. 

The front panel of the switch provides the following components:  

 

LEDs that display the status of the switch and the network 

 

Up to thirty-two 100 GbE ports 

The rear panel of the switch provides the following components:  

 

Two redundant hot-swap power supplies (1x IEC 320 C14 connector on each 
power supply) 

 

Fresh air duct to pull cold air in from the front of the rack when installed in the 
rear.

 

 

One RJ45 console port that provides another means to configure the switch 
module 

 

One USB port for mass storage devices 

 

Status LEDs for fans and power supplies 

 

Summary of Contents for 3454-CAC

Page 1: ... System Customer Install Guide 100G Spine Switch 3454 CAC Version 1 3 Note Before using this information and the product it supports read the information in Safety notices on page 5 Notices on page 33 the IBM Systems Safety Notices manual G229 9054 and the IBM Environmental Notices and User Guide ...

Page 2: ...e 100G Switch 2 This edition applies to IBM Cloud Pak for Data System Components Revised November 2021 Copyright IBM Corporation 2020 2021 US Government Users Restricted Rights Use duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp ...

Page 3: ...hardware specifications 15 Operating Environment 16 Rack requirements 17 Rack space 17 Location in the rack 18 Package contents 20 Contents 00RR851 duct kit 20 Contents 3454 CAC spine switch 21 Installation procedure 21 Installing 100G spine switches in a rack 21 Before you begin 21 About this task 21 Electronic Emissions Notices 27 Regulatory and Compliance 32 Notices 33 Copyright License 36 Trad...

Page 4: ... dette produkt Lees voordat u dit product installeert eerst de veiligheidsvoorschriften Ennen kuin asennat tämän tuotteen lue turvaohjeet kohdasta Safety Information Avant d installer ce produit lisez les consignes de sécurité Vor der Installation dieses Produkts die Sicherheitshinweise lesen Prima di installare questo prodotto leggere le Informazioni sulla Sicurezza Les sikkerhetsinformasjonen Sa...

Page 5: ...mber This number is used to cross reference an English language caution or danger statement with translated versions of the caution or danger statement in the Safety Notices Translation document PN G229 9054 For example if a caution statement is labeled D005 translations for that caution statement are in the Safety Notices Translation document under D005 Be sure to read all caution and danger stat...

Page 6: ...he outlet supplies proper voltage and phase rotation according to the system rating plate o For racks with a DC power distribution panel PDP connect the customer s DC power source to the PDP Ensure that the proper polarity is used when attaching the DC power and DC power return wiring Connect any equipment that will be attached to this product to properly wired outlets When possible use one hand o...

Page 7: ...ucted otherwise 7 Attach all cables to the devices 8 Attach the signal cables to the connectors 9 For AC power attach the power cords to the outlets 10 For racks with a DC power distribution panel PDP restore the power from the Customer s DC power source and turn on the circuit breakers located in the PDP 11 Turn on the devices Sharp edges corners and joints may be present in and around the system...

Page 8: ...e requirements of DHHS 21 CFR Subchapter J for class 1 laser products Outside the U S they are certified to be in compliance with IEC 60825 as a class 1 laser product Consult the label on each part for laser certification numbers and approval information CAUTION Data processing environments can contain equipment transmitting on system links with laser modules that operate at greater than Class 1 p...

Page 9: ...ANGER Observe the following precautions when working on or around your IT rack system Heavy equipment personal injury or equipment damage might result if mishandled Always lower the leveling pads on the rack cabinet Always install stabilizer brackets on the rack cabinet unless the earthquake option is to be installed To avoid hazardous conditions due to uneven mechanical loading always install the...

Page 10: ...urce when directed to disconnect power during servicing Connect all devices installed in a rack cabinet to power devices installed in the same rack cabinet Do not plug a power cord from a device installed in one rack cabinet into a power device installed in a different rack cabinet An electrical outlet that is not correctly wired could place hazardous voltage on the metal parts of the system or th...

Page 11: ...s this label L001 L002 DANGER Rack mounted devices are not to be used as shelves or work spaces Do not place objects on top of rack mounted devices In addition do not lean on rack mounted devices and do not use them to stabilize your body position for example when working from a ladder L002 CAUTION This part or unit is heavy but has a weight smaller than 18 kg 39 7 lb Use care when lifting or inst...

Page 12: ...ove all hazardous voltages disconnect all power cords and power cables L003 Product safety notifications Japan English translation If this product comes with power cords such cords should be used exclusively for the applicable product but not for other devices English translation After providing the main product if additional power cord is required the cord is handled for repair maintenance mendin...

Page 13: ... Component Racks Component Specific Install Guides Customer Install Guide 100G Switch 3454 CAC this document Customer Install Guide 2U Chassis 3453 C2E Customer Install Guide 1G Switch 3454 A3C Customer Install Guide 25G Switch 3454 B8C 3454 C8C Customer Install Guide Power Distribution Unit PDU 3454 FCE FCG Customer Install Guide 1U Chassis 3455 D3E Customer Install Guide Connector Node 3453 F7E ...

Page 14: ... fresh air duct kit that directs cold air from the front of the rack to the power supply side inlets DO NOT BLOCK ANY INLET OR EXHAUST DUCTS VENTS OR PORTS Blocked cooling access will adversely affect the performance of your Cloud Pak for Data System and may void your warranty Power can be supplied by the available IBM Cloud Pak for Data System PDUs and line cords or by customer supplied PDUs meet...

Page 15: ...s 1 2 Table 1 Width Depth Height EIA units Weight Amperage Max Power Max Cooling Max 428 mm 16 84 in 686 mm 27 0 in 43 8 mm 1 72 in 1 11 1 kg 24 5 lb 2 3 amps 460 watts 1570 BTU Hr Notes 1 The power supplies automatically accept any voltage within the 200 240 V AC 50 60 Hz rated voltage range If dual power supplies are installed and operating the power supplies draw approximately equal current fro...

Page 16: ...C 50F 95F 1 5 5C 45C 41F 113F Humidity 25 60 noncondensing 2 4 20 80 noncondensing 2 4 8 85 4 Maximum Operating Altitude 3050m 10 000 ft 1 Shipping Temperature 40C 60C 40F 140F 3 4 Shipping relative humidity 8 90 4 1 Derate maximum allowable dry bulb temperature by 1C 1 8F per 300m 984 ft increase in altitude above 950m 2 953 ft 2 Maximum dewpoint 21 C 70 F 3 Short term temperature only for server...

Page 17: ...nformation on the space requirements for the rack which will house the Cloud Pak for Data System Components Rack space Ensure that the rack in which you plan to install the system meets the space requirements outlined in the following figure Figure 1 Top down view of installed switch with 4 point horizontal mounting ...

Page 18: ...igure 2 below Other configurations can be used if IBM Safety Notices translations Pub G229 9054 rules are followed and the lengths of the supplied cables are not exceeded The Cloud Pak for Data System requires all IBM supplied and serviceable components to be installed below the 42U height Components on slides such as server chassis and connector nodes must be located at or below U26 Figure 2 Fron...

Page 19: ...5G switch in any convenient location see Figure 2 for recommended switch location U25 U26 1G Switch The 1G switch should typically be installed above the 25G switch see Figure 2 for recommended switch location U28 PDUs Install horizontally at U33 U38 for easy cable routing and service access Note alternating PDU orientation to denote left and right power Spine switches should be installed in rack ...

Page 20: ...to the rack that you are installing the system in square or round rail holes Duct kit 00RR851 Customized for IBM racks with 720mm depth Duct kit components 2x Rack mount rails A 2x Rack mount brackets B 2x Rack mount blades C 1x Air duct unit D M6 screws and nuts E 8x M6 Standard cage nuts 8x M6 standard G nuts 8x M6 Standard pan head Phillips screws 8x Phillips 6 32 X 1 4 screws with a round patc...

Page 21: ...ow direction will affect the heat dissipation Switches must plan for power supply to connector airflow i e switch network connections must be facing the rear of the rack The switch includes a fresh air duct kit that directs cold air from the front of the rack to the power supply side inlets DO NOT BLOCK ANY INLET OR EXHAUST DUCTS VENTS OR PORTS Blocked cooling access will adversely affect the perf...

Page 22: ... right rack mount brackets B to the switch by gently pushing the switch chassis pins through the slider key holes until locking occurs Secure the system in the brackets with the remaining 4 flat head Phillips screws F using a 1 5 0 2 Nm torque in the designated points See Figure 4 Figure 4 Attaching the Brackets to the Chassis 3 Install 8 nuts in the desired 1U slots of the rack 4 nuts in the rear...

Page 23: ... ships with a cable management bar Only one cable management bar is needed for every two switches This bar should be mounted using the topmost screw on the top switch blade U31 This mounting location will place the cable mounting bar directly between the two spine switches 6 Secure the system in the rack by tightening the 8 screws inserted in Step 4 and Step 5 with a 4 5 0 5 Nm torque Figure 6 Sli...

Page 24: ...ped with multiple AC power cords or multiple DC power cables To remove all hazardous voltages disconnect all power cords and power cables L003 8 Mount the air duct unit to the rack by sliding it forward through the brackets walls The air duct unit has two slotted foam panels to block air recirculation within the rack while ensuring a smooth passage of the cables The unit should slide smoothly If i...

Page 25: ...k is properly grounded and that there is a valid ground connection between the chassis of the switch and the rack Test the ground using an Ohm meter 2 Some national and or local codes may require IT components to be bonded and externally grounded not including the power cord ground You must follow all national and local codes when installing this equipment ...

Page 26: ... HOT AIR FROM RECIRCULATING TO THE FRONT OF THE RACK AND INTO THE COLD AIR INLETS DO NOT BLOCK ANY INLET OR EXHAUST DUCTS VENTS OR PORTS KEEP ALL POWER CORDS SIGNAL CABLES AND TRANSCEIVERS WITH THE INSTALLED CHASSIS FOR USE BY IBM INSTALLERS DO NOT POWER ON THIS CHASSIS POWER ON WILL BE DONE BY YOUR IBM INSTALLATION TEAM ...

Page 27: ...quipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits Proper cables and connectors are available from IBM authorized dealers IBM is not responsible for any radio or television interference caus...

Page 28: ...idential areas Such use must be avoided unless the user takes special measures to reduce electromagnetic emissions to prevent interference to the reception of radio and television broadcasts Warning This equipment is compliant with Class A of CISPR 32 In a residential environment this equipment may cause radio interference Germany Notice Deutschsprachiger EU Hinweis Hinweis für Geräte der Klasse A...

Page 29: ...chtlinie 2014 30 EU in der Bundesrepublik Deutschland Zulassungsbescheinigung laut dem Deutschen Gesetz über die elektromagnetische Verträglichkeit von Geräten EMVG bzw der EMC Richtlinie 2014 30 EU für Geräte der Klasse A Dieses Gerät ist berechtigt in Übereinstimmung mit dem Deutschen EMVG das EG Konformitätszeichen CE zu führen Verantwortlich für die Einhaltung der EMV Vorschriften ist der Hers...

Page 30: ...C 61000 3 2 適合品 本装置は 高圧又は特別高圧で受電する需要家の高調波抑制 対策ガイドライン 対象機器 高調波発生機器 です 回路分類 6 単相 PFC回路付 換算係数 0 Japan Voluntary Control Council for Interference VCCI Notice この装置は クラス A 情報技術装置です この装置を家庭環境で使用すると電波妨害 を引き起こすことがあります この場合には使用者が適切な対策を講ずるよう要求され ることがあります VCCI A Korea Notice 이 기기는 업무용 환경에서 사용할 목적으로 적합성평가를 받은 기기로서 가정용 환경에서 사용하는 경우 전파간섭의 우려가 있습니다 People s Republic of China Notice 警 告 此为 A 级产品 在生活环 境中 该产品可能会造成无 ...

Page 31: ...時 可能會造成射 頻擾動 在此種情況下 使用者會被要求採取某些適當的對策 IBM Taiwan Contact Information United Kingdom Notice This product may cause interference if used in residential areas Such use must be avoided unless the user takes special measures to reduce electromagnetic emissions to prevent interference to the reception of radio and television broadcasts ...

Page 32: ... Copyright IBM Corporation 2020 2021 Customer Install Guide 100G Switch 32 Regulatory and Compliance ...

Page 33: ... Director of Licensing IBM Corporation North Castle Drive Armonk NY 10504 1785 U S A For license inquiries regarding double byte DBCS information contact the IBM Intellectual Property Department in your country or send inquiries in writing to IBM World Trade Asia Corporation Licensing 2 31 Roppongi 3 chome Minato ku Tokyo 106 0032 Japan The following paragraph does not apply to the United Kingdom ...

Page 34: ...ent IBM International Program License Agreement or any equivalent agreement between us Any performance data contained herein was determined in a controlled environment Therefore the results obtained in other operating environments may vary significantly Some measurements may have been made on development level systems and there is no guarantee that these measurements will be the same on generally ...

Page 35: ...data and reports used in daily business operations To illustrate them as completely as possible the examples include the names of individuals companies brands and products All of these names are fictitious and any similarity to the names and addresses used by an actual business enterprise is entirely coincidental ...

Page 36: ...grams conforming to the application programming interface for the operating platform for which the sample programs are written These examples have not been thoroughly tested under all conditions IBM therefore cannot guarantee or imply reliability serviceability or function of these programs Each copy or any portion of these sample programs or any derivative work must include a copyright notice as ...

Page 37: ... or other countries Microsoft Windows Windows NT and the Windows logo are trademarks of Microsoft Corporation in the United States other countries or both Linux is a registered trademark of Linus Torvalds in the United States other countries or both UNIX is a registered trademark of The Open Group in the United States and other countries Oracle and Java are registered trademarks of Oracle and or i...

Page 38: ...r technical questions and information about products and prices please contact your IBM branch office your IBM business partner or your authorized remarketer When you send comments to IBM you grant IBM a nonexclusive right to use or distribute your comments in any way it believes appropriate without incurring any obligation to you IBM or any other organizations will only use the personal informati...

Page 39: ... Copyright IBM Corporation 2020 2021 Customer Install Guide 100G Switch 39 ...

Page 40: ... Copyright IBM Corporation 2020 2021 Customer Install Guide 100G Switch 40 Part Number 03GJ004 Printed in Mexico ...

Reviews: