background image

 
 

© Copyright IBM Corporation 2019, 2020, 2021.        Customer Install Guide, 2U Chassis 

32 

 
 

 

Generelle Informationen: 

 

 

Das Gerät erfüllt die Schutzanforderungen nach EN 55024 und EN   

 

 

55032 Klasse A. 

 

Industry Canada Class A Emission Compliance Statement 

This Class A digital apparatus compliance with CAN ICES-3 (A)/NMB-3(A). 
 

 
 
 
 
 
 
 
 
 
 
European Community and Morocco Notice 

This product is in conformity with the protection requirements of Directive 2014/30/EU of 
the European Parliament and of the Council on the harmonization of the laws of the 
Member States relating to electromagnetic compatibility. IBM cannot accept 
responsibility for any failure to satisfy the protection requirements resulting from a non-
recommended modification of the product, including the fitting of non-IBM option cards. 
This product may cause interference if used in residential areas. Such use must be 
avoided unless the user takes special measures to reduce electromagnetic emissions to 
prevent interference to the reception of radio and television broadcasts. 
Warning: This equipment is compliant with Class A of CISPR 32. In a residential 
environment this equipment may cause radio interference. 
 

Germany Notice 

Deutschsprachiger EU Hinweis: Hinweis für Geräte der Klasse A EU-Richtlinie zur 
Elektromagnetischen Verträglichkeit 

Dieses Produkt entspricht den Schutzanforderungen der EU-Richtlinie 2014/30/EU zur 
Angleichung der Rechtsvorschriften über die elektromagnetische Verträglichkeit in den 
EU-Mitgliedsstaatenund hält die Grenzwerte der EN 55032 Klasse A ein.  

Um dieses sicherzustellen, sind die Geräte wie in den Handbüchern beschrieben zu 
installieren und zu betreiben. Des Weiteren dürfen auch nur von der IBM empfohlene 
Kabel angeschlossen werden. IBM übernimmt keine Verantwortung für die Einhaltung 
der Schutzanforderungen, wenn das Produkt ohne Zustimmung von IBM verändert bzw. 

Summary of Contents for 3453-C2E

Page 1: ...r Data system Customer Install Guide Chassis 3453 C2E Version 1 9 Note Before using this information and the product it supports read the information in Safety notices on page 5 Notices on page 37 the...

Page 2: ...2U Chassis 2 This edition applies to IBM Cloud Pak for Data System Components Revised November 2021 Copyright IBM Corporation 2019 2020 2021 US Government Users Restricted Rights Use duplication or d...

Page 3: ...ystem 2U server chassis 16 Operating Environment 17 Rack Requirements 18 Rack Space 18 Location in the Rack 19 Package Contents 22 Chassis Installation Procedure 23 Rack rail parts inventory 23 Instal...

Page 4: ...sikkerhedsforskrifterne f r du installerer dette produkt Lees voordat u dit product installeert eerst de veiligheidsvoorschriften Ennen kuin asennat t m n tuotteen lue turvaohjeet kohdasta Safety Info...

Page 5: ...n this documentation is labeled with a number This number is used to cross reference an English language caution or danger statement with translated versions of the caution or danger statement in the...

Page 6: ...t the outlet supplies proper voltage and phase rotation according to the system rating plate For racks with a DC power distribution panel PDP connect the customer s DC power source to the PDP Ensure t...

Page 7: ...les from the connectors Remove all cables from the devices To connect Turn off everything unless instructed otherwise Attach all cables to the devices Attach the signal cables to the connectors For AC...

Page 8: ...result in exposure to hazardous laser radiation There are no serviceable parts inside the device Use of the controls or adjustments or performance of procedures other than those specified herein migh...

Page 9: ...end is not recommended To verify continuity of a fiber optic cable use an optical light source and power meter C027 CAUTION This product contains a Class 1M laser Do not view directly with optical in...

Page 10: ...e when working from a ladder Each rack cabinet might have more than one power cord o For AC powered racks be sure to disconnect all power cords in the rack cabinet when directed to disconnect power du...

Page 11: ...nstall Guide 2U Chassis 11 CAUTION Use safe practices when lifting L001 DANGER Hazardous voltage current or energy levels are present inside any component that has this label attached Do not open any...

Page 12: ...GER Rack mounted devices are not to be used as shelves or work spaces Do not place objects on top of rack mounted devices In addition do not lean on rack mounted devices and do not use them to stabili...

Page 13: ...e all hazardous voltages disconnect all power cords and power cables L003 Product Safety Notifications Japan English translation If this product comes with power cords such cords should be used exclus...

Page 14: ...H Component Racks Component Specific Install Guides Customer Install Guide 100G Switch 3454 CAC Customer Install Guide 2U Chassis 3453 C2E this document Customer Install Guide 1G Switch 3454 A3C Custo...

Page 15: ...es multiple cold air inlets used to draw in cold air from the front of the rack DO NOT BLOCK ANY INLET OR EXHAUST DUCTS VENTS OR PORTS Blocked cooling access will adversely affect the performance of y...

Page 16: ...ee Notes 1 2 Table 1 Width Depth Height EIA units Weight Amperage Max Power Max Cooling Max 488 mm 19 3 in 891 5 mm 35 1 in 87 mm 3 5 in 2 55 kg 121 2 lb 10 amps 2000 watts 6800 BTU Hr Notes 1 The pow...

Page 17: ...5C 50F 95F 1 5 5C 45C 41F 113F Humidity 25 60 noncondensing 2 4 20 80 noncondensing 2 4 8 85 4 Maximum Operating Altitude 3050m 10 000 ft 1 Shipping Temperature 40C 60C 40F 140F 3 4 Shipping relative...

Page 18: ...information on the space requirements for the rack which will house the Cloud Pak for Data System Components Rack Space Ensure that the rack in which you plan to install the system meets the space req...

Page 19: ...ed and serviceable components to be installed below the 42U height Components on slides such as server chassis and connector nodes must be located at or below U26 Figure 2 Front view of installed base...

Page 20: ...s Additional PDUs should be installed above the PDUs at locations U35 U36 Other components should be installed per the specific install guide included with those components Installation Notes Server n...

Page 21: ...lank Panel 22 1U Blank Panel 21 1U Blank Panel 20 1U Blank Panel 19 1U Blank Panel 18 1U Blank Panel 17 1U Blank Panel 16 1U Blank Panel 15 Chassis 5 14 13 1U Blank Panel 12 Chassis 4 11 10 1U Blank P...

Page 22: ...ncludes the following parts Two power cords Slide box kit The slide box kit includes the following parts One right slide One left slide Two M5 screws Two washers I O kit DO NOT DISCARD Keep with chass...

Page 23: ...rack Read the Rack safety notices Pub G229 9054 included with the unit C010 This unit weighs approximately 121 2lb 55kg IBM recommends the use of an appropriate lifting device to position the chassis...

Page 24: ...shown in the following illustration Procedure 1 Select the first slide rail you want to install Figure 4 2 Make sure the slide rail is shortened to the shortest position 3 From the front of the rack...

Page 25: ...A flange holes at the front of the rack Figure 6 Note The holes on the rack will either be square shaped or round shaped Figure 6 Left slide front installation 6 Repeat steps 2 to 5 to install the oth...

Page 26: ...d they must not be removed from the chassis during the chassis installation process Figure 7 Node locations in chassis and chassis marking To install the enclosure on the rails complete the following...

Page 27: ...Enclosure 5 Tilt and lower the enclosure then push the slides toward the enclosure and make sure the farthest nailheads go into the slots on the slides Figure 10 6 Slowly lower the enclosure down and...

Page 28: ...tegral component of the system design Their use is critical for effective installation for reliability of operation and for ease and effectiveness of service The cable management arms allow for orderl...

Page 29: ...he cable management bar from the tray pins and reinstalling it on the opposite side of the tray pins See Figures 12 13 14 Figure 12 Cable management arm right orientation must be reversed to left orie...

Page 30: ...ce ALL OPEN RACK BAYS REQUIRE FILLERS TO PREVENT HOT AIR FROM RECIRCULATING TO THE FRONT OF THE RACK AND INTO THE COLD AIR INLETS DO NOT BLOCK ANY INLET OR EXHAUST DUCTS VENTS OR PORTS KEEP ALL POWER...

Page 31: ...equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Properly shielded and grounded cables and...

Page 32: ...esidential areas Such use must be avoided unless the user takes special measures to reduce electromagnetic emissions to prevent interference to the reception of radio and television broadcasts Warning...

Page 33: ...ichtlinie 2014 30 EU in der Bundesrepublik Deutschland Zulassungsbescheinigung laut dem Deutschen Gesetz ber die elektromagnetische Vertr glichkeit von Ger ten EMVG bzw der EMC Richtlinie 2014 30 EU f...

Page 34: ...er Install Guide 2U Chassis 34 IBM Documentation This statement applies to products less than or equal to 20 A per phase JIS C 61000 3 2 Japan Voluntary Control Council for Interference VCCI Notice A...

Page 35: ...Notice IBM Taiwan Contact Information United Kingdom Notice This product may cause interference if used in residential areas Such use must be avoided unless the user takes special measures to reduce e...

Page 36: ...Copyright IBM Corporation 2019 2020 2021 Customer Install Guide 2U Chassis 36 Regulatory and Compliance...

Page 37: ...and services offered in the U S A IBM Director of Licensing IBM Corporation North Castle Drive Armonk NY 10504 1785 U S A For license inquiries regarding double byte DBCS information contact the IBM...

Page 38: ...nder terms of the IBM Customer Agreement IBM International Program License Agreement or any equivalent agreement between us Any performance data contained herein was determined in a controlled environ...

Page 39: ...data and reports used in daily business operations To illustrate them as completely as possible the examples include the names of individuals companies brands and products All of these names are fict...

Page 40: ...ograms conforming to the application programming interface for the operating platform for which the sample programs are written These examples have not been thoroughly tested under all conditions IBM...

Page 41: ...d or other countries Microsoft Windows Windows NT and the Windows logo are trademarks of Microsoft Corporation in the United States other countries or both Linux is a registered trademark of Linus Tor...

Page 42: ...echnical questions and information about products and prices please contact your IBM branch office your IBM business partner or your authorized remarketer When you send comments to IBM you grant IBM a...

Page 43: ...Copyright IBM Corporation 2019 2020 2021 Customer Install Guide 2U Chassis 43...

Page 44: ...Copyright IBM Corporation 2019 2020 2021 Customer Install Guide 2U Chassis 44 Part Number 03GJ005 Printed in Mexico...

Reviews: