background image

Summary of Contents for 3174

Page 1: ..._ 3174 Establishment Controller Introduction 3270 Information Display System GA27 3850 0...

Page 2: ..._ 3174 Establishment Controller Introduction GA27 3850 0...

Page 3: ...ry Such references or information must not be construed to mean that IBM intends to announce such IBM products programming or services in your country Publications are not stocked at the address given...

Page 4: ...e the 3174 Configuration Support A and S Planning Guide GA27 3844 Utilities Guide GA27 3853 Central Site Customizing User s Guide GA23 0342 Configuration Support B Planning Guide GA27 3862 Utilities G...

Page 5: ...tatus Codes GA27 3832 To Obtain Data Stream Programming and Reference Information Functional Description GA23 0218 Data Stream Programmer s Reference GA23 0059 3174 Character Set Reference GA27 3831 3...

Page 6: ...v...

Page 7: ...vi IBM 3270 Information Display System 3174 Establishment Controller Introduction...

Page 8: ...4 Establishment Controller It is intended for customer data processing managers and technical planners It is also for IBM marketing representatives and installation planning representatives How This B...

Page 9: ...viii IBM 3270 Information Display System 3174 Establishment Controller Introduction...

Page 10: ...Multi Host Support 2 1 Central Site Customizing Utility CSCU 2 12 Central Site Change Management CSCM 2 13 Intelligent Printer Data Stream IPDS 2 15 Multiple Logical Terminals MLT 2 16 Country Extende...

Page 11: ...tems 5 1 Telecommunication Access Methods 5 1 Network Control 5 2 Cross Industry Licensed Programs 5 2 Information Center 5 2 Development Center 5 2 Office Systems 5 3 Database Data Communication Syst...

Page 12: ...device to controller and device to network Some devices are intelligent and can perform some data processing activities themselves some are dependent and need a controller to run Some devices and host...

Page 13: ...edium Cluster PC s Communication Facility 3174 Controller Large Cluster 3270 Device 3270 Device Figure 1 1 Overview of the IBM 3174 Establishment Controller Attachment 1 2 IBM 3270 Information Display...

Page 14: ...hosts to one 3174 port and up to three adapter features can be installed in the 3174 24 ASCII terminals Medium cluster Models 51 R 61 R 52R 62R 53R and 63R have a similar attachment flexibility but wi...

Page 15: ...e of the devices come with their own problem determination code For example the 3299 Terminal Multiplexer and the display stations are shipped with problem determination information The IBM 3270 Perso...

Page 16: ...ng Network Gateway feature Type 1 Teleprocessing Communication Adapter Type 2 Teleprocessing Communication Adapter 4Mbps Type 3 Communication Adapter Type 3A Dual speed 16 4Mbps Communication Adapter...

Page 17: ...11L 1R 11R 2R 12R 3R and 13R of the 3174 for a total of 24 ASCII ports These device attachments are in addition to the maximum of thirty two 3270 terminals One emulation adapter can be installed in Mo...

Page 18: ...of 300 1200 2400 4800 9600 and 19200 bits per second bps through modems over switched or nonswitched communication facilities or through direct connection without modems Terminal The following display...

Page 19: ...under the provisions of the IBM Multiple Supplier Systems Bulletin Personal computers operating in emulation mode as one of the above display stations can also attach to the 3174 controller provided...

Page 20: ...Operator indicator status is provided upon request on the 24th or 25th line of the ASCII display station RTM and Alert Network statistics for ASCII terminals are gathered in the same manner as 3270 t...

Page 21: ...nfiguration Support B they are shipped with a 2 4MB diskette drive If a second drive is installed it must be a 2 4MB diskette drive For Configuration Support A S Models 61 R 62R and 63R are shipped wi...

Page 22: ...an be defined to the host VTAM because of the gateway feature Depending upon the configuration and controller models involved it is possible that up to 250 Token Ring attached workstations or controll...

Page 23: ...4 and the Token Ring Network and provides for Transfer of data to and from the ring Detection of ring and protocol errors Configuration Support S Utility and Control diskettes are provided with the ga...

Page 24: ...ing facilities as either model 1R or 11 R Type 2 Teleprocessing Communication Adapter The Type 2 Teleprocessing Communication Adapter provides X 21 interface CCITT V 11 for SNA SDLC or X 25 remote lin...

Page 25: ...ontrollers can have a second diskette drive or a 20MB Fixed Disk These storage features are designed to support a basic functions For information about additional features and storage needs refer to t...

Page 26: ...s much as 4MB using the one module slot Storage expansion is not supported in the small cluster models of the controller Models 81 Rand 82R have 1MB of base storage and models 91 Rand 92R have 2MB of...

Page 27: ...way controllers that connect to a Token Ring Network support this option They are models 3R 13R 53R and 63R Note Other models that can be alternately configured to act as these models can support this...

Page 28: ...res the Central Site Customizing Utility to establish and maintain the central site library on a 3174 except Model 81R 91R 82R or 92R that has been designated as the central site controller Note If an...

Page 29: ...20MB Fixed Disk Drive improves usability by eliminating diskette swapping when libraries for large networks are being maintained For remote controllers it allows a backup copy of the current IML Contr...

Page 30: ...t to control Media handling Downloading and managing of symbol sets fonts and printer stored objects such as overlays and page segments The printer can later use the stored objects to construct a prin...

Page 31: ...interact with up to five host sessions depending upon the configuration support level The host sessions can be directly connected to a single IBM host and one or more ASCII hosts Each session can be c...

Page 32: ...supported network components The information is available to the host as soon as the request is made Serial Original Equipment Manufacture Interface SOEMI The Serial Original Equipment Manufacture Int...

Page 33: ...r Data Stream IPDS Multiple Logical Terminals MLT Country Extended Code Page CECP Response Time Monitor RTM Terminal Multiplexer Adapter TMA Network Asset Management Serial Original Equipment Manufact...

Page 34: ...ata processing system and the operation of attached terminals The attached terminals may be either of two kinds distributed function terminals DFTs or control unit terminals CUTs Distributed function...

Page 35: ...h to the 3270 Information Display System are 5560 50 40 Multiworkstations 6150 RT Personal Computer all models with 3278 3279 Emulation Adapter 6151 RT Personal Computer all models with 3278 3279 Emul...

Page 36: ...ches processor channels among I O controllers in a data processing center Its modular design allows individual 3814 units to be distributed through a large processing center to put switching capabilit...

Page 37: ...5209 provides the customer a means of using S 3x systems as a department computer while maintaining host applications on the 370 This eliminates dual terminals and printers and reduces the cabling imp...

Page 38: ...370 type channel adapter for local attachment and wi work in an SNA or non SNA environment It has 1MB base storage and one 5 1 4 inch 1 2MB high capacity diskette drive If the controller has one disk...

Page 39: ...5 the diskette drive is 1 2MB If the controller is shipped with Configuration Support B the drive is 2 4MB If the controller has one diskette drive and uses devices that require downstream load microc...

Page 40: ...t Communication Adapter see note Terminal Multiplexer Adapter Storage Expansion Encrypt Decrypt Adapter Type 3 Communication Adapter Type 3A Communication Adapter Note If you want to install the Concu...

Page 41: ...through a control unit terminal attached to any port or multiplexer This can be done without interrupting other terminals that are attached to the 3174 controller Offline tests are performed through t...

Page 42: ...uses devices that require downstream load microcode a second diskette drive or fixed disk must be installed A four port terminal adapter that attaches IBM 3299 Terminal Multiplexers and Terminal Mult...

Page 43: ...Adapters supports a maximum of thirty two 3270 terminals and 24 ASCII terminals Customizing is performed with a control unit terminal attached to port 0 of the 3174 Any terminal can be attached to por...

Page 44: ...board utilities Subsystem online tests and problem determination are performed through a control unit terminal attached to any port or multiplexer without interrupting other terminals attached to the...

Page 45: ...and one 5 1 4 inch 1 2MB high capacity diskette drive If the controller has one diskette drive and uses devices that require downstream load microcode a second diskette drive or fixed disk must be in...

Page 46: ...eature Asynchronous Emulation Adapter Type 3A Communication Adapter 20MB Fixed Disk Drive Storage Expansion Concurrent Communication Adapter The 3174 Model 53R connects to the IBM Token Ring Network I...

Page 47: ...erminals directly or sixteen 3270 terminals and eight ASCII terminals through one or two IBM 3299 Terminal Multiplexers Customizing is performed with a control unit terminal attached to port 0 of the...

Page 48: ...ette drive A four port terminal adapter supports four terminals directly or eight 3270 terminals through an IBM 3299 Terminal Multiplexer Customizing is performed with a control unit terminal attached...

Page 49: ...control panel The 91 R controller supports no customer installable features The 3174 Model 82R is a small cluster controller designed for remote operations It contains a Type 2 Communication Adapter...

Page 50: ...rough IBM 3299 Terminal Multiplexers Customizing is performed with a control unit terminal attached to port 0 of the 3174 Any terminal can be attached to port 0 at other times The 92R supports full ke...

Page 51: ...3 14 IBM 3270 Information Display System 3174 Establishment Controller Introduction...

Page 52: ...feet from the system channel depending upon the system and channel configuration Locally attached controllers are the models 1Land 11 L These models also attach to the IBM 3044 Fiber Optic Channel Ex...

Page 53: ...When using BSe protocol the following controllers can attach to a multipoint nonswitched network Models 1R 11 R 51 R 61 R 81 R and 91 R When using SOLe protocol the following controllers can attach t...

Page 54: ...hed network backup SNBU operation are 3863 3864 and 3865 5865 and 5866 5866 exception is 3276 A backup Control diskette configured for SNBU may be needed Switched network backup operation is initiated...

Page 55: ...4 4 IBM 3270 Information Display System 3174 Establishment Controller Introduction...

Page 56: ...s Advanced Communications Function Virtual Telecommunications Access Method ACF VTAM under DOS VS DOS VSE and OS VS Advanced Communications Function Telecommunications Access Method ACF TCAM under OS...

Page 57: ...ode that enables these CUT displays to report VPD Cross Industry Licensed Programs Financial Management System Instructional Systems IlASIIIPS Interactive Financial System IFS Interactive Personnel Sy...

Page 58: ...Time Sharing Option TSO TSO Extensions TSO E Virtual Storage Extendedllnteractive Computing and Control Facility VSEIICCF Virtual Storage Personal Computing VSPC Other Licensed Programs Communication...

Page 59: ...5 4 IBM 3270 Information Display System 3174 Establishment Controller Introduction...

Page 60: ...ices that attach to the 3174 see your IBM marketing representative Table of 3174 Controller Devices This section contains lists of devices that the 3174 Establishment Controller supports The lists are...

Page 61: ...otes 1 These display models are not supported on models 81 R 91 R 82R and 92R 2 ASCII display models require the Asynchronous Emulation Adapter AEA 3 Abbreviations that are used in this table are expl...

Page 62: ...270 4245 models 012 020 3270 4250 model 1 3270 5201 model R2T2 ASCII 5202 model R2T2 ASCII 5204 see note 3 ASCII 5210 model G1 G2 3270 5216 see note 3 ASCII 5218 see note 3 ASCII 5223 see note 3 ASCII...

Page 63: ...all models RT Personal Computer 5578 see note 2 workstation 7531 see note 2 Indust w 3270 Emulator 7532 see note 2 Indust w 3270 Emulator 7552 all models Industrial PC 8525 all models PS 2 Model 25 w...

Page 64: ...inal Personal Computer Personal System 2 Serial Original Equipment Manufacture Interface Note About Keyboards The keyboard models supported by the 3270 Information Display System are too numerous to l...

Page 65: ...ken Ring 0 0 0 X 0 0 0 X 0 0 X 0 0 X X X X X Network Gateway AEA 0 0 0 0 0 0 0 0 0 0 X 0 0 0 X X X X 2 4MB Diskette 0 0 0 0 B B B B 0 0 0 B B B X X B B Drive see note 3 Type 1 0 B X 0 0 B X 0 B X X B...

Page 66: ...ted in this table are also known by numbers For information about feature numbers see your IBM marketing representative 3 On Models 11 L 11 R 12R and 13R the 2 4MB diskette drive is a base feature onl...

Page 67: ...te configurations are for models that can contain in addition to their primary communication adapter a Type 1 Type 2 or Type 3 communication adapter Primary Configuration Additional Adapter Type Alter...

Page 68: ...CICS Customer Information Control System coax Coaxial cable COPICS Communication Oriented Product Information Control System CSCM Central site change management CSP Cross System Product CSCU Central...

Page 69: ...pment manufacturer p PA Program access PC Personal Computer PD Problem determination PLANCODE Planning Control and Decision Evaluation System PROFS Professional Office System PU Physical unit Q QBE Qu...

Page 70: ...ation VM Virtual machine VS Virtual Storage VSE Virtual Storage Extended VSPC Virtual Storage Personal Computing VTAM Virtual Telecommunications Access Method w WCC Write control character x XA Extend...

Page 71: ...X 4 IBM 3270 Information Display System 3174 Establishment Controller Introduction...

Page 72: ...using the 3270 data stream an ASCII terminal to communicate with an ASCII host through the 3174 and a 3270 terminal to communicate with an ASCII host using the DEC VT100 data stream or the IBM 3101 da...

Page 73: ...ata group on a chart 5 See terminal component configuration The arrangement of a computer system or network as defined by the nature number and chief characteristics of its functional units More speci...

Page 74: ...ing a display screen and an attached keyboard that allows a user to send information to or receive information from the system distributed function terminal OFT A programmable terminal that can perfor...

Page 75: ...s 5 The processing unit required to create and maintain PSS 6 Synonymous with host computer host system 1 A data processing system used to prepare programs and operating environments for use on anothe...

Page 76: ...nches Connections are made between data stations 2 A configuration of data processing devices and software connected for information interchange nonswltched line 1 A connection between systems or devi...

Page 77: ...cal structure formats protocols and operational sequences for transmitting information units through and controlling the configuration and operation of networks T telecommunication attached Pertaining...

Page 78: ...eption of data as needed to perform a job write control character WCC A character used in conjunction with a Write command to specify that a particular operation or combination of operations is to be...

Page 79: ...X 12 IBM 3270 Information Display System 3174 Establishment Controller Introduction...

Page 80: ...support 2 13 introduction 2 12 channel attachment 4 1 cluster definition 1 3 cluster continued large 1 3 medium 1 3 3 7 small 1 3 code page country extended 2 16 Concurrent Communication Adapter 2 11...

Page 81: ...fixed disk drive 2 6 G gateway feature components 2 8 explanation 2 7 host gateway relationship 2 7 microcode 2 8 problem determination 2 9 program support 2 8 gateway feature continued H Type 3A ada...

Page 82: ...se communication systems 5 3 development center 5 2 programming support continued for gateway 2 8 interactive programming support 5 3 introduction 1 3 licensed programs 5 2 network control 5 2 office...

Page 83: ...7 microcode 2 8 problem determination 2 9 program support 2 8 3174 workstation relationship 2 8 Type 1 Communication Adapter 2 9 Type 2 Communication Adapter 2 9 Type 3 Communication Adapter 2 9 Type...

Page 84: ...to which this form is addressed Please direct any requests for copies of publications or for assistance in using your IBM system to your IBM rep resentative or to the IBM branch office serving your l...

Page 85: ...old and tape FIRST CLASS PERMIT NO 40 ARMONK N Y POSTAGE WILL BE PAID BY ADDRESSEE International Business Machines Corporation Dept E02 P O Box 12195 Research Triangle Park N C 27709 9990 Please Do No...

Page 86: ..._ Printed in U S A File Number 36 38 370 4300 8100 3174 09 GA27 3850 0...

Reviews: