Table 4. Events for the Enclosure component (continued)
Event
Event Type
Severity
Message
Description
Cause
User Action
fan_speed_low
STATE_CHANGE
WARNIN
G
Fan {0} speed is
too low
The fan speed is
out of the tolerance
range
N/A
Check the enclosure
cooling module LEDs
for fan faults.
no_enclosure_data
STATE_CHANGE
WARNIN
G
Enclosure data and
state information
cannot be queried.
Cannot query the
enclosure details.
State reporting for
all enclosures and
canisters will be
incorrect.
The
mmlsenclosure
all -L -Y
command fails to
report any
enclosure data.
Run the
mmlsenclosure
command to check
for errors. Use the
lsmod
command to
verify that the
pemsmod
is loaded.
power_high_current
STATE_CHANGE
WARNIN
G
Power supply {0}
reports high
current.
The DC power
supply current is
greater than the
threshold.
N/A
N/A
power_high_voltage
STATE_CHANGE
WARNIN
G
Power supply {0}
reports high
voltage.
The DC power
supply voltage is
greater than the
threshold.
N/A
N/A
power_no_power
STATE_CHANGE
WARNIN
G
Power supply {0}
has no power.
Power supply has
no input AC power.
The power supply
may be turned off
or disconnected
from the AC supply.
N/A
N/A
power_supply_absent
STATE_CHANGE
WARNIN
G
Power supply {0} is
missing.
The power supply
is missing
N/A
N/A
power_supply_failed
STATE_CHANGE
WARNIN
G
Power supply {0} is
failed.
The power supply
state is failed.
N/A
N/A
power_supply_off
STATE_CHANGE
WARNIN
G
Power supply {0} is
off.
The power supply
is not providing
power.
N/A
N/A
power_supply_ok
STATE_CHANGE
INFO
Power supply {0} is
ok.
The power supply
state is ok.
N/A
N/A
power_switched_off
STATE_CHANGE
WARNIN
G
Power supply {0} is
switched off.
The requested on
bit is off, indicating
that the power
supply has not
been manually
turned on or been
requested to turn
on by setting the
requested on bit.
N/A
N/A
sideplane_failed
STATE_CHANGE
ERROR
sideplane {0}
failed.
The sideplane state
is failed.
N/A
N/A
sideplane_ok
STATE_CHANGE
INFO
sideplane {0} is ok. The sideplane state
is ok.
N/A
N/A
temp_bus_failed
STATE_CHANGE
WARNIN
G
Temperature
sensor {0} I2C bus
is failed.
The temperature
sensor I2C bus has
failed.
N/A
N/A
temp_high_critical
STATE_CHANGE
WARNIN
G
Temperature
sensor {0}
measured a high
temperature value.
The temperature
has exceeded the
actual high critical
threshold value for
at least one sensor.
N/A
N/A
temp_high_warn
STATE_CHANGE
WARNIN
G
Temperature
sensor {0}
measured a high
temperature value.
The temperature
has exceeded the
actual high warning
threshold value for
at least one sensor.
N/A
N/A
temp_low_critical
STATE_CHANGE
WARNIN
G
Temperature
sensor {0}
measured a low
temperature value.
The temperature
has fallen below
the actual low
critical threshold
value for at least
one sensor.
N/A
N/A
Chapter 1. Events 7
Summary of Contents for 3000 6.0.2
Page 1: ...IBM Elastic Storage System 3000 6 0 2 Service Guide IBM SC28 3187 01...
Page 4: ...Index 71 Index 71 iv...
Page 6: ...vi...
Page 8: ...viii...
Page 12: ...xii IBM Elastic Storage System 3000 Service Guide...
Page 30: ...18 IBM Elastic Storage System 3000 Service Guide...
Page 66: ...54 IBM Elastic Storage System 3000 Service Guide...
Page 72: ...60 IBM Elastic Storage System 3000 Service Guide...
Page 82: ...70 IBM Elastic Storage System 3000 Service Guide...
Page 84: ...72 IBM Elastic Storage System 3000 Service Guide...
Page 86: ...74 IBM Elastic Storage System 3000 Service Guide...
Page 87: ......
Page 88: ...IBM Product Number 5765 DME 5765 DAE SC28 3187 01...