Table 4. Events for the Enclosure component (continued)
Event
Event Type
Severity
Message
Description
Cause
User Action
enclosure_firmware_unknown
STATE_CHANGE
WARNIN
G
The firmware level
of enclosure {0} is
unknown.
The SAS card is
unable to read
enclosure
firmware.
The SAS card does
not report the
enclosure
firmware.
Check the SAS
connectivity from
node to enclosure.
Use the
mmlsrecoverygrou
p rg_name -L --
pdisk
command to
verify if all the paths
to pdisk are
available. Check the
SAS connectivity
using a combination
of the
mmgetpdisktopolo
gy
and the
topsummary
command. If there is
an issue with the SAS
HBA or SAS Cable,
reboot the node to
see if this resolves
the issue. If not
contact your IBM
representative.
enclosure_firmware_wrong
STATE_CHANGE
WARNIN
G
The firmware level
of enclosure {0} is
wrong.
The firmware level
of the enclosure is
wrong.
N/A
Check the installed
firmware level using
mmlsfirmware
command.
enclosure_found
INFO_ADD_ENTITY
INFO
Enclosure {0} was
found.
A GNR enclosure
listed in the IBM
Spectrum Scale
configuration was
detected.
N/A
N/A
enclosure_needsservice
STATE_CHANGE
WARNIN
G
Enclosure {0}
needs service.
The enclosure
needs service.
N/A
N/A
enclosure_ok
STATE_CHANGE
INFO
Enclosure {0} is ok. The enclosure state
is ok.
N/A
N/A
enclosure_unknown
STATE_CHANGE
WARNIN
G
Enclosure state {0}
is unknown.
The enclosure state
is unknown.
N/A
N/A
enclosure_vanished
INFO_DELETE_ENTIT
Y
INFO
Enclosure {0} has
vanished.
A GNR enclosure
listed in the IBM
Spectrum Scale
configuration was
not detected.
A GNR enclosure,
listed in the IBM
Spectrum Scale
configuration as
mounted before, is
not found. This
could be a valid
situation.
Run the
mmlsenclosure
command to verify
that all expected
enclosures exist.
esm_absent
STATE_CHANGE
WARNIN
G
ESM {0} is absent.
The ESM state is
not installed .
N/A
N/A
esm_failed
STATE_CHANGE
WARNIN
G
ESM {0} is failed.
The ESM state is
failed.
N/A
N/A
esm_ok
STATE_CHANGE
INFO
ESM {0} is ok.
The ESM state is
ok.
N/A
N/A
expander_absent
STATE_CHANGE
WARNIN
G
expander {0} is
absent.
The expander is
absent.
N/A
N/A
expander_failed
STATE_CHANGE
ERROR
expander {0} is
failed.
The expander state
is failed.
N/A
N/A
expander_ok
STATE_CHANGE
INFO
expander {0} is ok.
The expander state
is ok.
N/A
N/A
fan_failed
STATE_CHANGE
WARNIN
G
Fan {0} is failed.
The fan state is
failed.
N/A
N/A
fan_ok
STATE_CHANGE
INFO
Fan {0} is ok.
The fan state is ok.
N/A
N/A
fan_speed_high
STATE_CHANGE
WARNIN
G
Fan {0} speed is
too high
The fan speed is
out of the tolerance
range
N/A
Check the enclosure
cooling module LEDs
for fan faults.
6 IBM Elastic Storage System 3000: Service Guide
Summary of Contents for 3000 6.0.2
Page 1: ...IBM Elastic Storage System 3000 6 0 2 Service Guide IBM SC28 3187 01...
Page 4: ...Index 71 Index 71 iv...
Page 6: ...vi...
Page 8: ...viii...
Page 12: ...xii IBM Elastic Storage System 3000 Service Guide...
Page 30: ...18 IBM Elastic Storage System 3000 Service Guide...
Page 66: ...54 IBM Elastic Storage System 3000 Service Guide...
Page 72: ...60 IBM Elastic Storage System 3000 Service Guide...
Page 82: ...70 IBM Elastic Storage System 3000 Service Guide...
Page 84: ...72 IBM Elastic Storage System 3000 Service Guide...
Page 86: ...74 IBM Elastic Storage System 3000 Service Guide...
Page 87: ......
Page 88: ...IBM Product Number 5765 DME 5765 DAE SC28 3187 01...