Table 4. Events for the Enclosure component (continued)
Event
Event Type
Severity
Message
Description
Cause
User Action
temp_low_warn
STATE_CHANGE
WARNIN
G
Temperature
sensor {0}
measured a low
temperature value.
The temperature
has fallen below
the actual low
warning threshold
value for at least
one sensor.
N/A
N/A
temp_sensor_failed
STATE_CHANGE
WARNIN
G
Temperature
sensor {0} is failed.
The temperature
sensor state is
failed.
N/A
N/A
temp_sensor_ok
STATE_CHANGE
INFO
Temperature
sensor {0} is ok.
The temperature
sensor state is ok.
N/A
N/A
voltage_bus_failed
STATE_CHANGE
WARNIN
G
Voltage sensor {0}
I2C bus is failed.
The voltage sensor
I2C bus has failed.
N/A
N/A
voltage_high_critical
STATE_CHANGE
WARNIN
G
Voltage sensor {0}
measured a high
voltage value.
The voltage has
exceeded the
actual high critical
threshold value for
at least one sensor.
N/A
N/A
voltage_high_warn
STATE_CHANGE
WARNIN
G
Voltage sensor {0}
measured a high
voltage value.
The voltage has
exceeded the
actual high warning
threshold value for
at least one sensor.
N/A
N/A
voltage_low_critical
STATE_CHANGE
WARNIN
G
Voltage sensor {0}
measured a low
voltage value.
The voltage has
fallen below the
actual low critical
threshold value for
at least one sensor.
N/A
N/A
voltage_low_warn
STATE_CHANGE
WARNIN
G
Voltage sensor {0}
measured a low
voltage value.
The voltage has
fallen below the
actual low warning
threshold value for
at least one sensor.
N/A
N/A
voltage_sensor_failed
STATE_CHANGE
WARNIN
G
Voltage sensor {0}
is failed.
The voltage sensor
state is failed.
N/A
N/A
voltage_sensor_ok
STATE_CHANGE
INFO
Voltage sensor {0}
is ok.
The voltage sensor
state is ok.
N/A
N/A
Physical disk events
The following table lists the events that are created for the Physical disk component.
Table 5. Events for the physical disk component
Event
Event Type
Severity
Message
Description
Cause
User Action
gnr_nvram_degraded STATE_CHANGE
WARNING
The NVDIMM of the
pdisk {0} is degraded.
The NVRAM drive of
the disk is in
degraded
state.
The
tslsnvramstatus
command shows
degraded
state for the
NVRAM drive of the disk.
N/A
gnr_nvram_disarmed STATE_CHANGE
ERROR
The NVDIMM of the
pdisk {0} is disarmed.
NVDIMM is unable to
preserve future
content.
The
tslsnvramstatus
command reports
disarmed failure
condition for the NVRAM
drive of the disk.
Identify the
NVDIMM cards or
BPM, which
encountered the
errors from FSP log
or call home data,
and replace the
faulty NVDIMM
cards, BPM or both
as soon as possible.
8 IBM Elastic Storage System 3000: Service Guide
Summary of Contents for 3000 6.0.2
Page 1: ...IBM Elastic Storage System 3000 6 0 2 Service Guide IBM SC28 3187 01...
Page 4: ...Index 71 Index 71 iv...
Page 6: ...vi...
Page 8: ...viii...
Page 12: ...xii IBM Elastic Storage System 3000 Service Guide...
Page 30: ...18 IBM Elastic Storage System 3000 Service Guide...
Page 66: ...54 IBM Elastic Storage System 3000 Service Guide...
Page 72: ...60 IBM Elastic Storage System 3000 Service Guide...
Page 82: ...70 IBM Elastic Storage System 3000 Service Guide...
Page 84: ...72 IBM Elastic Storage System 3000 Service Guide...
Page 86: ...74 IBM Elastic Storage System 3000 Service Guide...
Page 87: ......
Page 88: ...IBM Product Number 5765 DME 5765 DAE SC28 3187 01...