background image

IBM 1500VA LCD 2U Rack Uninterruptible Power Supply for IBM System x

19

Notices

This information was developed for products and services offered in the U.S.A.

IBM may not offer the products, services, or features discussed in this document in other countries. Consult your local 
IBM representative for information on the products and services currently available in your area. Any reference to an 
IBM product, program, or service is not intended to state or imply that only that IBM product, program, or service may 
be used. Any functionally equivalent product, program, or service that does not infringe any IBM intellectual property 
right may be used instead. However, it is the user's responsibility to evaluate and verify the operation of any non-IBM 
product, program, or service. IBM may have patents or pending patent applications covering subject matter described 
in this document. The furnishing of this document does not give you any license to these patents. You can send 
license inquiries, in writing, to:

IBM Director of Licensing, IBM Corporation, North Castle Drive, Armonk, NY 10504-1785 U.S.A.

The following paragraph does not apply to the United Kingdom or any other country where such provisions 
are inconsistent with local law: 

INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS 

PUBLICATION "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT 
NOT LIMITED TO, THE IMPLIED WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS 
FOR A PARTICULAR PURPOSE. Some states do not allow disclaimer of express or implied warranties in certain 
transactions, therefore, this statement may not apply to you. This information could include technical inaccuracies or 
typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in 
new editions of the publication. IBM may make improvements and/or changes in the product(s) and/or the program(s) 
described in this publication at any time without notice.

Any references in this information to non-IBM Web sites are provided for convenience only and do not in any manner 
serve as an endorsement of those Web sites. The materials at those Web sites are not part of the materials for this 
IBM product and use of those Web sites is at your own risk.IBM may use or  distribute any of the information you 
supply in any way it believes appropriate without incurring any obligation to you. Information concerning non-IBM 
products was obtained from the suppliers of those products, their published announcements or other publicly 
available sources. IBM has not tested those products and cannot confirm the accuracy of performance, compatibility 
or any other claims related to non-IBM products. Questions on the capabilities of non-IBM products should be 
addressed to the suppliers of those products. This information contains examples of data and reports used in daily 
business operations. To illustrate them as completely as possible, the examples include the names of individuals, 
companies, brands, and products. All of these names are fictitious and any similarity to the names and addresses 
used by an actual business enterprise is entirely coincidental.

Any performance data contained herein was determined in a controlled environment. Therefore, the results obtained 
in other operating environments may vary significantly. Some measurements may have been made on 
development-level systems and there is no guarantee that these measurements will be the same on generally 
available systems. Furthermore, some measurement may have been estimated through extrapolation. Actual results 
may vary. Users of this document should verify the applicable data for their specific environment. 

COPYRIGHT LICENSE:

This information contains sample application programs in source language, which illustrate programming techniques 
on various operating platforms. You may copy, modify, and distribute these sample programs in any form without 
payment to IBM, for the purposes of developing, using, marketing or distributing application programs conforming to 
the application programming interface for the operating platform for which the sample programs are written. These 
examples have not been thoroughly tested under all conditions. IBM, therefore, cannot guarantee or imply reliability, 
serviceability, or function of these programs.

© Copyright International Business Machines Corporation 2010. All rights reserved.

Note to U.S. Government Users Restricted Rights -- Use, duplication or disclosure restricted by
GSA ADP Schedule Contract with IBM Corp.

Summary of Contents for 1500VA

Page 1: ...igure 1 IBM 1500VA LCD 2U Rack UPS for IBM System x Did You Know The IBM 1500VA UPS has a bright easily customizable and graphical LCD display that lets you configure the device and displays important...

Page 2: ...rs and feature codes for the IBM 1500VA UPS Table 1 Ordering part numbers and feature codes Description Part number Feature code IBM 1500VA LCD 2U Rack UPS 100V 120V 5395 1AX 5395 RU1 FC 6653 IBM 1500...

Page 3: ...C13 CNS 10917 2 8 m 81Y2374 Taiwan 10A 250V C13 CNS 10917 2 8 m 81Y2375 Brazil 10A 250V C13 to NBR 14136 2 8 m 69Y1988 Argentina 10A line C13 to IRAM 2063 2 8 m 39Y7930 4 3 m line cords Part number Eu...

Page 4: ...nd management Its load segments allow for individual control of receptacle groups maximizing run time for critical devices It has an optional network management card part number 46M4140 for enhanced U...

Page 5: ...t voltage regulation 92 108V 100V 100 121V 110V 106 132V 120V 208 253V 230V Input Nominal input voltage auto sensing at first power up 100 120V 220 230 240V user configurable Input frequency auto sens...

Page 6: ...rm Alarm when on battery Distinctive low battery alarm Remote Power Off REPO REPO port Surge Protection and Filtering Surge energy rating 1200 Joules 2400 Joules Filtering ANSI IEEE C62 41 1991 CATEGO...

Page 7: ...e IBM 1500VA LCD 2U Rack UPS has a three year limited warranty Supported rack installation The IBM 1500VA LCD 2U Rack UPS requires 2 U of rack space in one of the following rack cabinets IBM 42U Enter...

Page 8: ...Displays the output watts VA current power factor voltage frequency input voltage input frequency battery voltage and percentage charged Control screens Displays the battery test reset error state co...

Page 9: ...he UPS On some screens the OK button has an additional function if you press and hold the button longer than 1 second On the User Setting screens to save the displayed setting On the Meter and Notice...

Page 10: ...programmed and controlled allowing mission critical devices to be prioritized during shutdown to preserve battery run time Network Management Card The IBM 1500VA LCD 2U Rack UPS also comes equipped wi...

Page 11: ...tallation and optimization of backup time by shutting down non priority systems Allows protection by using an encrypted password Allows protection by using a secure SSL connection Allows log storage i...

Page 12: ...IBM 1500VA LCD 2U Rack Uninterruptible Power Supply for IBM System x 12 Figure 6 IBM LCD UPS Network Management Card NMC UPS properties window...

Page 13: ...s a power outage and the UPS battery power becomes low the software can automatically shut down the system to protect the data before the UPS shutdown occurs Figure 7 shows normal operating using the...

Page 14: ...x 14 Figure 8 shows that the utility power supply has failed and that the UPS is now operating on battery The UPS Manager software indicates that there is 10 minutes of battery time available based o...

Page 15: ...Uninterruptible Power Supply for IBM System x 15 Figure 9 shows the event notification window where you can configure how you and other users want to be notified when certain events occur Figure 9 Eve...

Page 16: ...cts to the Network Management Card NMC settings sensor connection Its temperature and humidity thresholds are easily set to trigger alarm notifications or shut down the protected system Its status can...

Page 17: ...center The IBM Systems Director Active Energy Manager AEM helps Collect power information from each device attached to an IBM UPS thus presenting a more complete view of energy usage With server conso...

Page 18: ...tmlfid 897 ENUS110 159 IBM System x UPS product page http www ibm com systems x hardware options upsrack html IBM 1500VA LCD 2U Rack Uninterruptible Power Supply Installation and Maintenance Guide htt...

Page 19: ...are not part of the materials for this IBM product and use of those Web sites is at your own risk IBM may use or distribute any of the information you supply in any way it believes appropriate withou...

Page 20: ...he IBM logo and ibm com are trademarks or registered trademarks of International Business Machines Corporation in the United States other countries or both These and other IBM trademarked terms are US...

Reviews: