Page 4
FUNCTION MENU
ADDR
001 - 512, DMX Address setting
CHND
11 ch
13 ch, select the channel mode
SHND
SHOW 0 – SHOW 4, Select the show mode
SLND
Mast
SL 1
SL 2 ( MASTER, SLAVE OPTION)
dINd
Dimmer Mode
Stda(Standard)
StGE(Stage)
tv(TV)
ArAL(Architectural)
tHAL(Theatrical)
AUTO
OFF (sound controlled mode)
ON (Auto Mode)
SENS
000 – 100 Sound sensitivity control (0 close, 100 The most sensitive)
PINT
Yes - No (PAN Reverse)
TINT
Yes - No (TIL Reverse)
LED
On - Off (Background LIGHT ON/OFF)
DISP
Disp
Dsip (Reverse Display)
TEST
Test
RSET
Reset
Settings
DMX Address Setting
1. Press the MENU, UP or DOWN button until “
ADDR
” is displayed, press ENTER.
2. The current address will now be displayed and flashing. Press the UP or DOWN buttons to find your desired
address.
3. Press ENTER to confirm.
DMX channel mode
1. Press the MENU button until “
CHND
” is displayed, press ENTER. Either “
11CH
”, “
13CH
” will be displayed
2. Press the UP or DOWN buttons to find your desired DMX channel mode and press ENTER to confirm and exit.
Show modes 0-4 (Factory programs).
Show mode can run with or without sound active mode active.
1. Press the MENU button until “
SHND
” is displayed, press ENTER.
2.
“Sh X”
will now be displayed, “X” representing a number between 0-4. Programs 1-4 are factory programs, while
“Sh 0” is random mode. Press the UP or DOWN buttons to find your desired show.
3. When you have found your desired show press ENTER.
dINd
This option is for setting dimmer curves. Press
MENU
to select
dINd
, Then press
Enter
to start setting,
UP
or
DOWN
to select the dimmer curves, there are five dimmer curves
Stda, StGE, tv, ArAL
and
tHAL
for your choice, then press
Enter
again to confirm your selection.
Stda Standard