Operation
DMX Address Code Setting
Every light should be set with DMX address code when you are using the
controller to control multi lights, it is used to receive the signal from the
controller. Since the product uses "address code dial code" set the address
code, so each dial code corresponding to address values are as follows:
Dial
code
1 2 3 4 5 6 7 8 9
Corresponding to
address code value
1 2 4 8 16 32 64 128
256
The present address code of the light =(address code of last light)+(channel quantity of the light).The light with 9
Channels, so it should be under the “16channel” control mode, the DMX address code of the first light is “1” the
corresponding dial code is "1" (or all of the dial code not dial),the second should be: 1+16=17; the corresponding
dial code is "1 +5", the third light address value is 1+16 * 2 = 33, the corresponding dial code is "1 +6 ", The fourth
should be 1 +16 * 3 = 49, the corresponding dial code is" 1 +5 +6 ", analogously.
Auto-mode
Dial the code 10 and 8 to ON, LED mini mushroom light in auto running mode. The dial codes 1, 2 and 3 are the
conversion of the different modes of auto running. Following the list:
DIP number
Function description
Remark
10+8 Auto
Auto-running show (include shade. strobe. change color and so
on)
10+8+1 R
shade
10+8+2 G
shade
10+8+3 B
shade
10+8+2+1
RGB
shade(speed1fast)
10+8+3+1 RGB
shade(speed2)
10+8+3+2
RGB
shade(speed3slow)
10+8+3+2+1 R+G+B
shade
Sound control mode
Dial the code 10 and 7 to ON, LED mini mushroom light will be in sound control mode. The dial code 1. 2. 3. 4
and 5 are the conversion of the different modes of sound control mode.
DIP number
Function
Remark
10+7 Sound
mode1
10+7+1 2
10+7+2 3
10+7+3 4
10+7+4 5
10+7+5 6
Setting master machine is when dial the code 10 to ON, control the slave machine can by DMX connect interface.
All dial code to OFF, when dial 10 to OFF, 1 to 9 is the light address code setting (8421 binary code format), are
all OFF, the address is 001.
Master-slave mode
Setup master machine and dial code 10 to ON, can control slave machine by DMX connect interface. All dial code
to OFF when slave machine receiving; 1-9 is the light address code setup (8421 Binary encoding format) when
dial 10 to OFF, the address code is 001 when all OFF.
Warm Tip: The light auto running effect, are selected from the control channel with the proceeds, so users can
use the DMX controller of have storage capabilities to make out the changers effect of your need.
© Copyright Lotronic 2009
4