background image

ibidi GmbH

Lochhamer Schlag 11

82166 Gräfelfing

Germany

Toll free within Germany:

Phone: 0800 / 00 11 11 28

Fax: 0800 / 00 11 11 29

International calls:

Phone: +49 89 / 520 46 17 - 0

Fax: 

+49 89 / 520 46 17 - 59

E-Mail: [email protected]

ibidi.com

.com

Summary of Contents for 12170

Page 1: ...rsal Silver Line Instruction Manual Objective Heater Universal Silver Line Version 1 0 for use with ibidi Heating System Slide Dish Silver Line and ibidi Heating System 4 Slides Silver Line 12110 12720 12722 12111 12130 12131 com ...

Page 2: ...Objective Heater Universal Silver Line Version 1 0 June 1 2022 2 Instruction Manual ...

Page 3: ...Universal Silver Line Contact ibidi GmbH Lochhamer Schlag 11 82166 Gra felfing Germany Phone 49 89 520 46 17 0 Fax 49 89 520 46 17 59 E mail info ibidi de Internet ibidi com Instruction Manual 3 Version 1 0 June 1 2022 ...

Page 4: ...r Universal Silver Line 9 1 10 Waste Disposal WEEE RoHS Compliance Statement 9 1 10 1 EU Directive WEEE 9 1 10 2 EU Directive RoHS 10 1 11 Regulatory Statement 11 2 Intended Use 12 3 Principle 12 4 Equipment 13 5 Operation 14 5 1 Installation and Connection of the Objective Heater Universal Silver Line 14 5 2 Emergency Release Mechanism 16 5 3 Temperature Adjustment of the Objective Heater Univers...

Page 5: ...s 12110 12720 12722 12111 and the Heating System 4 Slides Silver Line product numbers 12130 12131 1 3 Safety Symbols Note that the signal words WARNING CAUTION and NOTE have specific meanings in this man ual Do not proceed beyond a signal word until you have performed the indicated actions Warning messages in the text are displayed in a gray shaded box Please see section for general safety conside...

Page 6: ...ltage DC 24 V 2 A 48 W Operating Conditions Operating site Indoor use only Operating temperature 18 30 C 64 86 F min 5 C 9 F less than set tempera ture Humidity 80 relative humidity RH up to 31 C 87 F 30 relative humidity RH up to 40 C 104 F Operating altitude max 2000 m atmospheric pressure 800 1060 hPa 11 6 15 4 psi Storage conditions 5 50 C 23 122 F humidity 60 relative humidity RH Outer Dimens...

Page 7: ... does not guarantee the validity of any patent rights or other rights If an ibidi software program doesn t function properly this may be caused by a conflict from another program operating on the computer In this case take corrective action by uninstalling the conflicting product s ibidi is a registered trademark of ibidi GmbH in Germany and other countries 1 7 Safety Considerations WARNING Only o...

Page 8: ...e to the instrument Only ibidi technical staff and technical staff instructed by ibidi are permitted to open and ser vice the Objective Heater The Objective Heater should not come in contact with moisture If the housing is damaged the external power supply should not be used Avoid strong magnetic fields and sources of high frequency The Objective Heater might not function properly when located nea...

Page 9: ...roduct 1 9 Repairing the Objective Heater Universal Silver Line For inquiries concerning repair service contact ibidi GmbH technical support techsupport ibidi com and provide the model name and serial number of your system CAUTION Do not try to repair the Objective Heater by yourself Disassembly of the Objec tive Heater is not allowed Disassembly poses a risk of personal injury or damage to the de...

Page 10: ...designated WEEE collection facility for the proper collection and recycling of the waste equipment The separate collection and recycling of waste equipment will help to conserve natural resources and protect human health and the environment For more information about recy cling please contact your local environmental office an electrical electronic waste disposal company or distributor where you p...

Page 11: ...ation Laborgerät laboratory equipment ibidi Temperature Controller ibiTC3 XXX with ibidi accessories Der oben beschriebene Gegenstand erfüllt die Vorschriften der Richtlinie 2011 65 EU vom 08 Juni 2011 zur Beschränkung der Verwendung bestimmter gefährlicher Stoffe in Elektro und Elektronikgeräten The object of the declaration described above is in conformity with Directive 2011 65 EU of 8 June 201...

Page 12: ...table temperature of the sample Please note that the Objective Heater is designed for research purposes only 3 Principle Microscope objectives that require close approximation to the sample e g water and oil immersion objectives might cause cooling of the sample by thermal transfer from the sample to the objective when the objective is not heated Adequate heating of the objective by the Objective ...

Page 13: ...Silver Line 12170 are listed below Description Drawing Flexible heating unit red with piece of cable and part female of the break away connector Cable for connecting the Objective Heater to the Temperature Controller with part male of the break away connector converter box and plug Velcro fastener for holding the Objective Heater on the objective Instruction Manual 13 Version 1 0 June 1 2022 ...

Page 14: ...verlap when wrapped around the objective If there is no overlap proceed with steps 2A and 3A If there is an overlap which is not optimal for homoge nous heating proceed with steps 2B and 3B 2A Thread the blue end of the Velcro fastener through the metal buckle and create a loose loop that can be easily placed over the objective 3A Bend the heating unit of the Objective Heater around the objective ...

Page 15: ...ontrol the temperature of the Objective Heater please follow the instructions of the Temperature Controller see Instructions Optional To setup communication with the IncuControl Software use a USB cable to connect the Temperature Controller to the computer Instruction Manual 15 Version 1 0 June 1 2022 ...

Page 16: ...t transfer from the sample to the objective and vice versa The temperature of the Objective Heater is regulated by the Temperature Controller Please follow the instructions for temperature adjustment of the sample as described in the instructions of the Temperature Controller see Instructions 1 Adjust temperatures of Heated Plate and Heated Lid in a way that the target temperature for the sample i...

Page 17: ...rget temper ature The temperature adjustment must be repeated from time to time at least once a year especially if one of the following conditions has been changed Room temperature Air conditioning Chamber type or objective lens Humidification and gas flow Use of an XL incubator Instruction Manual 17 Version 1 0 June 1 2022 ...

Page 18: ...Objective Heater Universal Silver Line Version 1 0 June 1 2022 18 Instruction Manual ...

Page 19: ...Objective Heater Universal Silver Line Instruction Manual 19 Version 1 0 June 1 2022 ...

Page 20: ...chhamer Schlag 11 82166 Gräfelfing Germany Toll free within Germany Phone 0800 00 11 11 28 Fax 0800 00 11 11 29 International calls Phone 49 89 520 46 17 0 Fax 49 89 520 46 17 59 E Mail info ibidi com ibidi com com ...

Reviews: