5. Specifications
5.1. Interface Specifications
DC, Power port
Connector
M12 A-coded male
Rated voltage
24 VDC
Operating voltage
16.8 to 31.2 VDC
Rated current
0.6 A
Rated frequency
DC
Inrush current
44 mA
2
s at 24 VDC
Startup current
2 x rated current
Polarity
Reverse polarity protected
Redundant power input
No
Conductor cross section
(flexible)
> 0.5 mm² (AWG 20)
Cable temperature rating
-40 to +70°C
Shielded cable
Not required
PoE (on X2 only)
Connector
M12 X-coded female
Device mode
A and B
Rated voltage
48 VDC
Operating voltage
42.5 to 57 VDC
Power classification
Class 4
Ethernet TX
Connector
M12 X-coded female
Electrical specification
IEEE std 802.3
Data rate
10 Mbit/s, 100 Mbit/s, 1000 Mbit/s, manual or auto
Duplex
Full or half, manual or auto
Transmission range
Up to 100 m with CAT5e cable or better
Cabling
Shielded cable CAT5e or better is recommended
Conductive chassis
Yes
Ibex-RT-330-5G Series
25