![IBEX Gast 1HAA Operation & Maintenance Manual Download Page 16](http://html.mh-extra.com/html/ibex/gast-1haa/gast-1haa_operation-and-maintenance-manual_605504016.webp)
TROUBLESHOOTING CHART
www.gastmfg.com
ISO 9001 & 14001 CERTIFIED
inc.
Low
High
Pump
Motor
Excess
Reason and remedy
Vacuum
Pressure
Vacuum
Pressure
Overheat
Overload
Noise
for problem.
•
•
•
•
Filter dirty. Clean or replace.
•
At pump
•
•
•
Muffler dirty. Clean or replace.
•
•
•
Valves dirty or valves bent.
Clean or replace.
•
•
•
Damaged or worn piston rings.
Repair or replace.
•
•
•
Leaky relief valve.
Inspect and adjust.
•
•
•
Damaged valves.
Replace.
•
At pump
•
•
•
•
Plugged vacuum/pressure line.
Inspect and repair.
•
•
•
•
Low voltage, won’t start.
Check power source.
•
•
•
Worn rings/piston hitting cylinder.
Replace.
•
•
•
•
Cylinder misadjustment.
Realign.
•
•
•
Leaky hose or check valve.
Replace.
•
•
•
•
•
Dirt or liquid on top of piston.
Inspect and clean.
•
•
•
Blown head gasket.
Replace.
PART NO. 70 - 2100 G441PL (REV-K)